文献速递重症综合管理与镇静镇痛心脑血管急症

多普勒超声心动图指标预测机械通气危重患者肺动脉闭塞压:特异但不敏感

Doppler Echocardiographic Indices Are Specific But Not Sensitive to Predict Pulmonary Artery Occlusion Pressure in Critically Ill Patients Under Mechanical Ventilation.
PubMed 文献 · Crit Care Med · 2021-01-01
一句话结论机械通气危重患者中,多普勒超声心动图指标预测PAOP≥18 mmHg特异度高但敏感度低,多数E/E'测值落在7–15灰区。

该前瞻性观察研究在Amiens大学医院内科ICU纳入53例窦性心律的机械通气患者,同步行经胸超声心动图与肺动脉导管测压。PAOP与E/E'侧壁比值(r=0.35,p<0.01)、E/A比值(r=0.41,p<0.002)、E波减速时间(r=-0.34,p<0.02)显著相关。E/E'>15预测PAOP≥18 mmHg的敏感度25%、特异度95%;E/A>1.8敏感度44%、特异度95%。E/E'<7预测PAOP<18 mmHg敏感度32%、特异度81%;E/A<0.7敏感度19%、特异度94%。作者结论:多普勒超声指标预测PAOP高度特异但不敏感。

要点

  • E/E'>15预测PAOP≥18 mmHg特异度95%但敏感度仅25%,阳性可支持高PAOP,阴性不能排除。
  • E/A>1.8预测PAOP≥18 mmHg特异度95%、敏感度44%,特异度与E/E'相当而敏感度略高。
  • E/E'<7预测PAOP<18 mmHg敏感度32%、特异度81%;E/A<0.7敏感度19%、特异度94%。
  • 32例(60%)的E/E'测值落在7–15之间,即ROC曲线两切点构成的灰区,无法据此判断PAOP高低。
  • 在EF<50%的患者中分析,各指标的预测能力相似。

适用人群与场景

  • Amiens大学医院内科ICU收治的53例机械通气、窦性心律的危重患者。

诊断标准与关键阈值

  • 以肺动脉导管测得的PAOP≥18 mmHg为高PAOP判定界值,PAOP<18 mmHg为低PAOP。
  • E/E'>15预测PAOP≥18 mmHg,E/E'<7预测PAOP<18 mmHg。
  • E/A>1.8预测PAOP≥18 mmHg,E/A<0.7预测PAOP<18 mmHg。
  • E/E'测值在7–15之间为灰区(ROC曲线两切点之间),本研究中占32例(60%)。

研究设计与关键结果

  • 前瞻性观察研究,单中心(Amiens大学医院内科ICU),纳入53例机械通气窦性心律患者,同步行经胸超声心动图与肺动脉导管测压。
  • PAOP与E/E'侧壁比值显著相关(r=0.35,p<0.01),与E/A比值显著相关(r=0.41,p<0.002),与E波减速时间显著相关(r=-0.34,p<0.02)。
  • E/E'>15预测PAOP≥18 mmHg:敏感度25%,特异度95%。
  • E/E'<7预测PAOP<18 mmHg:敏感度32%,特异度81%。
  • E/A>1.8预测PAOP≥18 mmHg:敏感度44%,特异度95%。
  • E/A<0.7预测PAOP<18 mmHg:敏感度19%,特异度94%。
  • 在EF<50%的患者中分析,预测能力相似。
  • E/E'测值位于7–15之间者32例(60%)。

证据类型、等级与局限

  • 证据类型:前瞻性观察研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者结论:在机械通气危重患者中,多普勒经胸超声心动图指标预测PAOP高度特异但不敏感。
  • E/E'>15或E/A>1.8时阳性发现可支持PAOP≥18 mmHg,但敏感度低,阴性结果不能排除高PAOP。
  • E/E'在7–15之间时(本研究中占60%)无法依据该指标判断PAOP高低。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: The objective of this study was to prospectively evaluate the ability of transthoracic echocardiography to assess pulmonary artery occlusion pressure in mechanically ventilated critically ill patients.

DESIGN: In a prospective observational study.

SETTING: Amiens University Hospital Medical ICU.

PATIENTS: Fifty-three mechanically ventilated patients in sinus rhythm admitted to our ICU.

INTERVENTION: Transthoracic echocardiography was performed simultaneously to pulmonary artery catheter.

MEASUREMENTS AND MAIN RESULTS: Transmitral early velocity wave recorded using pulsed wave Doppler (E), late transmitral velocity wave recorded using pulsed wave Doppler (A), and deceleration time of E wave were recorded using pulsed Doppler as well as early mitral annulus velocity wave recorded using tissue Doppler imaging (E'). Pulmonary artery occlusion pressure was measured simultaneously using pulmonary artery catheter. There was a significant correlation between pulmonary artery occlusion pressure and lateral ratio between E wave and E' (E/E' ratio) (r = 0.35; p < 0.01), ratio between E wave and A wave (E/A ratio) (r = 0.41; p < 0.002), and deceleration time of E wave (r = -0.34; p < 0.02). E/E' greater than 15 was predictive of pulmonary artery occlusion pressure greater than or equal to 18 mm Hg with a sensitivity of 25% and a specificity of 95%, whereas E/E' less than 7 was predictive of pulmonary artery occlusion pressure less than 18 mm Hg with a sensitivity of 32% and a specificity of 81%. E/A greater than 1.8 yielded a sensitivity of 44% and a specificity of 95% to predict pulmonary artery occlusion pressure greater than or equal to 18 mm Hg, whereas E/A less than 0.7 was predictive of pulmonary artery occlusion pressure less than 18 mm Hg with a sensitivity of 19% and a specificity of 94%. A similar predictive capacity was observed when the analysis was confined to patients with EF less than 50%. A large proportion of E/E' measurements 32 (60%) were situated between the two cut-off values obtained by the receiver operating characteristic curves: E/E' greater than 15 and E/E' less than 7.

CONCLUSIONS: In mechanically ventilated critically ill patients, Doppler transthoracic echocardiography indices are highly specific but not sensitive to estimate pulmonary artery occlusion pressure.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Mercado P, Maizel J, Marc J, et al. Doppler Echocardiographic Indices Are Specific But Not Sensitive to Predict Pulmonary Artery Occlusion Pressure in Critically Ill Patients Under Mechanical Ventilation. Crit Care Med. 2021. PMID: 33337748. doi:10.1097/CCM.0000000000004702

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。