文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

猪心脏骤停模型中胸外按压与除颤产生的气溶胶

Aerosol generation during chest compression and defibrillation in a swine cardiac arrest model.
PubMed 文献 · Resuscitation · 2020-12-15
一句话结论猪心骤停模型中单纯胸外按压不显著产生气溶胶,但除颤后即刻胸外按压产生更多气溶胶,提示除颤后按压需加强防护。

研究用3头雌性未插管猪模拟目击性心脏骤停:4分钟室颤无胸外按压/除颤(no-flow),随后10个2分钟周期机械胸外按压+除颤不供氧。用粒子分析仪测0.3-10μm气溶胶。除颤前按压与no-flow总量无显著差异;除颤后按压气溶胶显著多于除颤前按压或no-flow(72.4±41.6×10^4 vs 12.3±8.3×10^4 vs 10.5±11.2×10^4,p<0.05),且粒径增大。两次人咳嗽产54.7±33.9×10^4个,粒径小于除颤后按压。结论:单纯按压不显著产气溶胶,除颤后即刻按压产气溶胶增加;需进一步研究临床意义与机制。

要点

  • 除颤后即刻胸外按压产生的气溶胶显著多于除颤前按压或no-flow(72.4±41.6×10^4 vs 12.3±8.3×10^4 vs 10.5±11.2×10^4,p<0.05)。
  • 单纯胸外按压(除颤前)与no-flow相比气溶胶总量无显著差异。
  • 除颤后按压产生的气溶胶粒径向更大颗粒偏移。
  • 两次人咳嗽产生54.7±33.9×10^4个气溶胶,粒径小于除颤后按压。
  • 猪模型为未插管、无通气、机械按压+除颤,临床转化需进一步研究。

适用人群与场景

  • 猪心脏骤停模型:3头雌性未插管猪,模拟目击性心脏骤停且 bystander 启动心肺复苏。
  • 原文未提及人类急诊/ICU适用人群或排除人群。

诊断标准与关键阈值

  • 原文未提及

处置流程与药物剂量

  • 原文未提及

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 研究类型:动物实验(猪心脏骤停模型),样本量3头雌性未插管猪,单中心(原文未明确中心数)。
  • 干预:4分钟室颤无胸外按压/除颤(no-flow),随后10个2分钟周期机械胸外按压+除颤不供氧;对照为no-flow和除颤前按压。
  • 主要终点:除颤后胸外按压气溶胶总量显著高于除颤前按压或no-flow(72.4±41.6×10^4 vs 12.3±8.3×10^4 vs 10.5±11.2×10^4,p<0.05),粒径向大颗粒偏移;除颤前按压与no-flow无显著差异。
  • 其他:两次人咳嗽产54.7±33.9×10^4个气溶胶,粒径小于除颤后按压。

证据类型、等级与局限

  • 证据类型:动物实验(猪模型),非RCT;原文未给出证据等级或推荐强度。
  • 局限:样本量小(3头猪)、动物模型、未插管无通气、机械按压、单中心(原文未明确),临床意义需进一步研究。

对床旁实践的改变

  • 在猪模型中,除颤后即刻胸外按压产生更多气溶胶,提示临床中除颤后按压操作可能需加强呼吸道防护;但原文未给出人类推荐,需进一步研究证实。
  • 单纯胸外按压(除颤前)在模型中未显著增加气溶胶,但不应据此放松防护,原文未做临床推荐。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

AIM: It remains unclear whether cardiac arrest (CA) resuscitation generates aerosols that can transmit respiratory pathogens. We hypothesize that chest compression and defibrillation generate aerosols that could contain the SARS-CoV-2 virus in a swine CA model.

METHODS: To simulate witnessed CA with bystander-initiated cardiopulmonary resuscitation, 3 female non-intubated swine underwent 4 min of ventricular fibrillation without chest compression or defibrillation (no-flow) followed by ten 2-min cycles of mechanical chest compression and defibrillation without ventilation. The diameter (0.3-10 μm) and quantity of aerosols generated during 45-s intervals of no-flow and chest compression before and after defibrillation were analyzed by a particle analyzer. Aerosols generated from the coughs of 4 healthy human subjects were also compared to aerosols generated by swine.

RESULTS: There was no significant difference between the total aerosols generated during chest compression before defibrillation compared to no-flow. In contrast, chest compression after defibrillation generated significantly more aerosols than chest compression before defibrillation or no-flow (72.4 ± 41.6 × 104 vs 12.3 ± 8.3 × 104 vs 10.5 ± 11.2 × 104; p < 0.05), with a shift in particle size toward larger aerosols. Two consecutive human coughs generated 54.7 ± 33.9 × 104 aerosols with a size distribution smaller than post-defibrillation chest compression.

CONCLUSIONS: Chest compressions alone did not cause significant aerosol generation in this swine model. However, increased aerosol generation was detected during chest compression immediately following defibrillation. Additional research is needed to elucidate the clinical significance and mechanisms by which aerosol generation during chest compression is modified by defibrillation.

来源:Resuscitation,查看原文。版权归原作者所有。