文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

急诊困难静脉通路:护士实施超声引导下外周静脉置管的表现与影响

Difficult intravenous access in the emergency department: Performance and impact of ultrasound-guided IV insertion performed by nurses.
PubMed 文献 · Am J Emerg Med · 2020-11-07
一句话结论急诊困难静脉通路(DIVA)发生率为8.9%,护士实施超声引导下外周静脉置管可缩短置管、检验、镇痛及急诊停留时间。

该回顾性研究纳入2015—2017年某三级学术医疗中心147,260例急诊患者,将需要≥3次外周静脉置管尝试或需超声引导下外周静脉置管者定义为DIVA,共13,192例(8.9%)。DIVA患者较无DIVA患者在静脉通路建立时间、检验结果回报时间、静脉镇痛给药时间及急诊停留时间上均显著延迟(均p<0.001)。在DIVA患者中,护士实施超声引导下外周静脉置管较医生实施者上述各项指标均显著改善(均p<0.001)。提示护士主导的超声引导置管可改善DIVA患者的急诊流程效率。

要点

  • DIVA定义为需要≥3次外周静脉置管尝试或需超声引导下外周静脉置管,本研究中占急诊患者的8.9%(13,192/147,260)。
  • DIVA患者较无DIVA患者在静脉通路建立时间、检验结果回报时间、静脉镇痛给药时间及急诊停留时间上均显著延迟(均p<0.001)。
  • 在DIVA患者中,护士实施超声引导下外周静脉置管较医生实施者在上述四项指标上均显著改善(均p<0.001)。
  • 该研究为单中心回顾性研究,结果支持在急诊由护士开展超声引导下外周静脉置管以改善DIVA相关流程延迟。

适用人群与场景

  • 2015—2017年某三级学术医疗中心急诊科所有置入外周静脉导管的患者。
  • DIVA患者:需要≥3次外周静脉置管尝试或需超声引导下外周静脉置管者。

诊断标准与关键阈值

  • DIVA判定标准:需要≥3次外周静脉置管尝试,或需要超声引导下外周静脉置管。

处置流程与药物剂量

  • 原文未提及

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 研究类型:单中心回顾性电子病历查询研究;样本量147,260例急诊患者;研究期间2015—2017年。
  • DIVA发生率为8.9%(13,192/147,260)。
  • DIVA患者较无DIVA患者在静脉通路建立时间、检验结果回报时间、静脉镇痛给药时间及急诊停留时间上均显著延迟(均p<0.001)。
  • 在DIVA患者中,护士实施超声引导下外周静脉置管较医生实施者在静脉通路建立时间、检验结果回报时间、静脉镇痛给药时间及急诊停留时间上均显著改善(均p<0.001)。

证据类型、等级与局限

  • 证据类型:单中心回顾性研究。

对床旁实践的改变

  • 对需要≥3次外周静脉置管尝试或需超声引导下外周静脉置管的急诊DIVA患者,由护士实施超声引导下外周静脉置管可缩短静脉通路建立、检验结果回报、静脉镇痛给药及急诊停留时间。
  • 该研究为单中心回顾性设计,适用性需结合本机构护士超声置管培训与资质情况;原文未提及不适用人群。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

BACKGROUND: Difficult intravenous access (DIVA) is a common problem in Emergency Departments (EDs), yet the prevalence and clinical impact of this condition is poorly understood. Ultrasound-guided peripheral intravenous catheter (USGPIV) insertion is a successful modality for obtaining intravenous (IV) access in patients with DIVA.

OBJECTIVES: We aimed to describe the prevalence of DIVA, explore how DIVA affects delivery of care, and determine if nurse insertion of USGPIV improves care delays among patients with DIVA.

METHODS: We retrospectively queried the electronic medical record for all ED patients who had a peripheral IV (PIV) inserted at a tertiary academic medical center from 2015 to 2017. We categorized patients as having DIVA if they required ≥3 PIV attempts or an USGPIV. We compared metrics for care delivery including time-to-IV-access, time-to-laboratory-results, time-to-IV-analgesia, and ED length of stay (LOS) between patients with and without DIVA. We also compared these metrics in patients with DIVA with a physician-inserted USGPIV versus those with a nurse-inserted USGPIV.

RESULTS: A total of 147,260 patients were evaluated during the study period. Of these, 13,192 (8.9%) met criteria for DIVA. Patients with DIVA encountered statistically significant delays in time-to-IV-access, time-to-laboratory-results, time-to-IV-analgesia, and ED LOS compared to patients without DIVA (all p < 0.001). Patients with nurse-inserted USGPIVs also had statistically significant improvements in time-to-IV-access, time-to-laboratory-results, time-to-IV-analgesia, and ED LOS compared to patients with physician-inserted USGPIVs (all p < 0.001).

CONCLUSION: DIVA affects many ED patients and leads to delays in PIV access-related care. Nurse insertion of USGPIVs improves care in patients with DIVA.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Davis EM, Feinsmith S, Amick AE, et al. Difficult intravenous access in the emergency department: Performance and impact of ultrasound-guided IV insertion performed by nurses. Am J Emerg Med. 2020. PMID: 33191044. doi:10.1016/j.ajem.2020.11.013

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。