文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

急诊急性呼吸困难患者膈肌移动度测量预测机械通气需求

Diaphragmatic excursion measurement in emergency department patients with acute dyspnea to predict mechanical ventilation use.
PubMed 文献 · Am J Emerg Med · 2020-06-26
一句话结论在急诊急性呼吸困难患者中,入院时RDE值未能定义与后续机械通气需求相关的预后阈值;非COPD患者以2.18 cm为阈值时NPV为92%。

这项双中心前瞻性观察研究纳入102例急诊急性呼吸困难患者,入院时测量右侧膈肌移动度(RDE),以4小时内是否使用机械通气(MV)定义需求。通气组与非通气组RDE分别为1.7 cm和2.2 cm(p=0.06),AUC 0.68(95%CI 0.57-0.80)。以2 cm为阈值,灵敏度76%、特异度59%、NPV 81%、PPV 53%。在非COPD患者中,通气组与非通气组RDE分别为1.5 cm和2.2 cm(p<0.01),AUC 0.77(95%CI 0.64-0.90),以2.18 cm为阈值时灵敏度91%、特异度51%、NPV 92%、PPV 54%。结论认为RDE在整体AD患者中无法定义预测MV需求的阈值,非COPD患者NPV较高。

要点

  • 整体急性呼吸困难患者中,入院RDE预测4小时内机械通气的AUC仅0.68(95%CI 0.57-0.80),未能确定有效预后阈值。
  • 非COPD亚组以RDE 2.18 cm为阈值,NPV达92%(95%CI 75%-99%),可辅助排除后续机械通气需求。
  • 非COPD亚组RDE在通气组为1.5 cm、非通气组为2.2 cm(p<0.01),AUC 0.77(95%CI 0.64-0.90)。
  • 整体人群以2 cm为阈值时灵敏度76%、特异度59%、NPV 81%、PPV 53%,预测价值有限。
  • 该研究为双中心前瞻性观察研究,样本量102例,结果需外部验证。

适用人群与场景

  • 急诊就诊的急性呼吸困难成人患者,年龄中位数79岁(IQR 70-86)。
  • 研究纳入双中心前瞻性观察队列,排除标准原文未提及。
  • 非COPD亚组为本文重点分析人群。

诊断标准与关键阈值

  • 机械通气需求定义为急性呼吸困难管理后4小时内使用机械通气。
  • RDE最佳阈值通过最高Youden指数确定,即最小化4小时内机械通气使用错误预测的值。
  • 整体人群阈值2 cm;非COPD患者阈值2.18 cm。

处置流程与药物剂量

  • 原文未提及

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 双中心前瞻性观察研究,纳入102例急诊急性呼吸困难患者,38例(37%)接受机械通气。
  • 通气组与非通气组RDE分别为1.7 cm和2.2 cm(p=0.06),AUC 0.68(95%CI 0.57-0.80)。
  • 以2 cm为阈值,灵敏度76%(95%CI 60%-89%)、特异度59%(95%CI 46%-71%)、NPV 81%(95%CI 67%-91%)、PPV 53%(95%CI 39%-66%)。
  • 非COPD患者中,通气组与非通气组RDE分别为1.5 cm和2.2 cm(p<0.01),AUC 0.77(95%CI 0.64-0.90)。
  • 非COPD患者以2.18 cm为阈值,灵敏度91%(95%CI 71%-99%)、特异度51%(95%CI 36%-66%)、NPV 92%(95%CI 75%-99%)、PPV 54%(95%CI 38%-69%)。

证据类型、等级与局限

  • 证据类型:双中心前瞻性观察研究。
  • 证据等级或推荐强度:原文未提及。
  • 局限:样本量102例,单次RDE测量,未提及盲法,需外部验证。

对床旁实践的改变

  • 在非COPD急性呼吸困难患者中,入院RDE≥2.18 cm对排除4小时内机械通气需求有较高NPV(92%),可辅助临床决策。
  • 在整体急性呼吸困难患者中,RDE预测机械通气价值有限(AUC 0.68),不应单独用于决定是否启动机械通气。
  • COPD患者中RDE的预测价值未确立,研究显示整体人群阈值不适用。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

INTRODUCTION: Ultrasound is a feasible and reproducible method for measuring right diaphragmatic excursion (RDE) in ED patients with acute dyspnea (AD). In AD patients, the correlation between the RDE value and the need for mechanical ventilation (MV) is not known.

MATERIALS: This was a bicentric, observational prospective study. The RDE measurement was done at admission. The need for MV was defined by the use of MV within 4 h of AD management. An optimal threshold for RDE was determined as the value that minimized the incorrect predictions of the use of MV in the first 4 h as the highest Youden index.

RESULTS: We analyzed 102 patients (79 [70; 86] years), 38 (37%) of whom had been ventilated. The RDE value was 1.7 cm [1.4; 2.0] and 2.2 cm [1.8; 2.6] in the ventilated and non-ventilated groups, respectively (p = 0.06). The AUC was 0.68 95% CI [0.57; 0.80]. With a threshold of 2 cm, the sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) were 76% [60%; 89%], 59% [46%; 71%], 81% [67%; 91%], and 53% [39%; 66%], respectively. In the non-COPD patients, the RDE values were 1.5 cm [1.2; 1.9] and 2.2 cm [1.8; 2.6] (p < 0.01) in the ventilated and not-ventilated groups, respectively. The AUC was 0.77 95% CI [0.64; 0.90]. With a threshold of 2.18 cm, the sensitivity, specificity, NPV, and PPV were 91% [71%; 99%], 51% [36%; 66%], 92% [75%; 99%], and 54% [38%; 69%], respectively.

CONCLUSION: The RDE values at ED admission were unable to define a prognostic threshold value associated with subsequent MV need in the AD patients. In non-COPD patients, the NPV was 92%.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Clément A, Zieleskiewicz L, Bonnec JM, et al. Diaphragmatic excursion measurement in emergency department patients with acute dyspnea to predict mechanical ventilation use. Am J Emerg Med. 2020. PMID: 33142179. doi:10.1016/j.ajem.2020.06.044

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。