文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

重症患者持续气囊压力监测下的机械通气压力研究

[Study on mechanical ventilation pressure under continuous cuff pressure monitoring in critical patients].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2020-01-01
一句话结论对非肺部疾病机械通气重症患者,气囊压力维持20 cmH2O与25、30 cmH2O相比不增加机械通气时间和住院时间,且气道黏膜损伤更少。

该研究纳入天津医科大学机场医院ICU 2017年6月至2019年6月收治的90例非肺部疾病机械通气重症患者,随机分为三组,每组30例,气囊压力分别维持20、25、30 cmH2O。结果显示30 cmH2O组气道黏膜损伤例数显著高于20 cmH2O组(8例 vs 4例,P<0.05),20与25 cmH2O组间、25与30 cmH2O组间黏膜损伤无显著差异;三组漏气、气管导管移位、呼吸机相关性肺炎、机械通气时间和ICU住院时间均无显著差异。作者认为20 cmH2O不增加机械通气时间和住院时间,且在气道黏膜损伤方面更安全。

要点

  • 非肺部疾病机械通气重症患者气囊压力维持20 cmH2O与25、30 cmH2O相比,机械通气时间和ICU住院时间无显著差异。
  • 30 cmH2O组气道黏膜损伤例数显著高于20 cmH2O组(8例 vs 4例,P<0.05)。
  • 20与25 cmH2O组间、25与30 cmH2O组间气道黏膜损伤无显著差异。
  • 三组漏气(14、10、12例)、气管导管移位(18、11、16例)、呼吸机相关性肺炎(3、4、3例)均无显著差异(P>0.05)。
  • 作者认为20 cmH2O不增加机械通气时间和住院时间,且在气道黏膜损伤方面更安全。

适用人群与场景

  • 天津医科大学机场医院ICU 2017年6月至2019年6月收治的非肺部疾病机械通气重症患者90例,随机分为三组,每组30例。

处置流程与药物剂量

  • 三组患者均床头抬高30度并持续监测气囊压力,气囊压力分别维持20、25、30 cmH2O(1 cmH2O=0.098 kPa)。
  • 患者平静时每小时记录漏气、血氧饱和度、气管导管移位情况;拔管时用纤维支气管镜吸痰检查黏膜损伤;行胸部X线检查评估肺部感染并同时行痰细菌培养。

研究设计与关键结果

  • 三组性别、年龄和病情严重程度无显著差异。
  • 30 cmH2O组气道黏膜损伤例数显著高于20 cmH2O组(8例 vs 4例,P<0.05);20与25 cmH2O组间、25与30 cmH2O组间气道黏膜损伤无显著差异。
  • 气囊压力20、25、30 cmH2O时,漏气(14、10、12例)、气管导管移位(18、11、16例)、呼吸机相关性肺炎(3、4、3例)均无显著差异(P>0.05)。
  • 三组机械通气时间(小时:77.07±65.34、80.80±70.20、77.60±65.23)和ICU住院时间(天:5.70±3.74、5.30±4.57、6.23±3.51)均无显著差异(P>0.05)。

证据类型、等级与局限

  • 研究类型:随机对照研究(随机数字表分组),单中心,样本量90例。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为20 cmH2O气囊压力不增加机械通气时间和住院时间,且在气道黏膜损伤方面更安全。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To explore the effective pressure range under continuous cuff pressure monitoring in critical patients with mechanical ventilation, so as to achieve the goal of ensuring ventilation quality and reducing mucosal injury without increasing the incidence of endotracheal catheter displacement and aspiration.

METHODS: Ninety critically ill patients with non-pulmonary diseases admitted to the department of intensive care unit (ICU) of Airport Hospital of Tianjin Medical University from June 2017 to June 2019 were enrolled, and divided into three groups according to the random number table, with 30 patients in each group. For all patients in the three groups , the head of the bed was raised by 30 degree angleand the balloon was measured continuously. Cuff pressure in the three groups were maintained at 20, 25 and 30 cmH2O (1 cmH2O = 0.098 kPa) respectively. The patient's air leakage, oxygen saturation, tracheal tube displacement of each group were recorded every hour when the patients were calm. Fiberbronchoscope was used to aspirate sputum during extubation to check for mucosal damage. Chest X-ray examination was used to evaluate pulmonary infection and sputum bacteria culture examination was conducted at the same time.

RESULTS: There was no significant difference in gender, age and critical condition among the three groups. The number of patients with airway mucosal injury in the 30 cmH2O group was significantly higher than that in the 20 cmH2O group (cases: 8 vs. 4, P < 0.05). There was no significant difference in airway mucosal injury between Group 20 cmH2O and Group 25, Group 25 cmH2O and Group 30 cmH2O. When the balloon pressure was 20, 25, and 30 cmH2O, there was no significant difference in air bag leakage (cases: 14, 10, 12), trachea catheter displacement (cases: 18, 11, 16), ventilator-associated pneumonia (cases: 3, 4, 3), all P > 0.05, and there was no significant difference in mechanical ventilation time and the hospitalization time [mechanical ventilation time (hours): 77.07±65.34, 80.80±70.20, 77.60±65.23; the length of ICU stay (days): 5.70±3.74, 5.30±4.57, 6.23±3.51, all P > 0.05].

CONCLUSIONS: The cuff pressure of 20 cmH2O will not increase the mechanical ventilation time and hospitalization time of patients, while 20 cmH2O is much safer in airway mucosal injury.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Wang S, Lu M, Xu Y, et al. [Study on mechanical ventilation pressure under continuous cuff pressure monitoring in critical patients]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2020. PMID: 33198876. doi:10.3760/cma.j.cn121430-20200714-00523

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。