文献速递呼吸衰竭与机械通气心脑血管急症

多中心实施自动化年龄校正D-二聚体结果减少不必要的PE影像检查

Multi-center implementation of automated age-adjusted D-dimer results reduces unnecessary PE imaging.
PubMed 文献 · Am J Emerg Med · 2020-11-03
一句话结论多中心实施自动化年龄校正D-二聚体使PE影像检查减少4.4%,同时提高检测准确率。

该回顾性前后对照研究纳入6家医院、40万急诊就诊区域医疗系统,比较实施年龄校正D-二聚体界值(>50岁患者正常上限改为年龄×0.01 μg/mL)前后1.5年数据。实施后D-二聚体阳性比例由48.6%降至43.2%(p<0.01),影像检查由32.3%降至28.0%(p<0.05),相对风险降低13.3%,绝对减少4.4%(少1104次扫描),检测准确率由53.7%升至59.2%(p<0.05)。

要点

  • 在>50岁急诊患者中,实施自动化年龄校正D-二聚体界值(年龄×0.01 μg/mL)后影像检查减少4.4%。
  • 实施后D-二聚体阳性率由48.6%降至43.2%(p<0.01),影像检查率由32.3%降至28.0%(p<0.05)。
  • 检测准确率由53.7%升至59.2%(p<0.05),相对风险降低13.3%。
  • 6家医院区域系统实施后绝对减少1104次CT和V/Q扫描,未报告死亡率变化。
  • 自动化年龄校正结果以正常/升高显示,可系统化减少不必要的PE影像检查。

适用人群与场景

  • 6家医院、40万急诊就诊的区域医疗系统中,2015年9月至2018年9月急诊就诊并完成D-二聚体检测的所有患者。

诊断标准与关键阈值

  • 年龄校正D-二聚体正常上限:>50岁患者为年龄(岁)×0.01 μg/mL,系统自动按此调整并以正常或升高显示结果。
  • 原文未提及具体的PE诊断流程或排除标准。

处置流程与药物剂量

  • 第一步:对急诊疑似PE患者进行D-二聚体检测。
  • 第二步:>50岁患者采用自动化年龄校正界值(年龄×0.01 μg/mL)判读结果。
  • 第三步:结果正常者不进行CT或V/Q影像检查,结果升高者进一步影像检查。

红旗征与不能漏的情况

  • 原文未提及具体红旗征或不能漏诊的情况。

研究设计与关键结果

  • 研究类型:回顾性前后对照实施研究,6家医院,区域医疗系统40万急诊就诊。
  • 实施前22302次D-二聚体,10837次(48.6%)阳性,7218次(32.3%)影像检查。
  • 实施后25082次D-二聚体,10851次(43.2%)阳性,7017次(28.0%)影像检查。
  • 阳性率下降(48.6% vs 43.2%,p<0.01),影像检查率下降(32.3% vs 28.0%,p<0.05),相对风险降低13.3%。
  • 绝对风险降低4.4%,实施后组减少1104次扫描,检测准确率由53.7%升至59.2%(p<0.05)。

证据类型、等级与局限

  • 证据类型:回顾性前后对照实施研究(非随机),来自6家医院区域医疗系统。
  • 局限:回顾性设计、非随机、单区域医疗系统,原文未提及证据等级或推荐强度。

对床旁实践的改变

  • 对>50岁急诊疑似PE患者,采用自动化年龄校正D-二聚体界值可减少不必要的CT和V/Q影像检查。
  • 系统自动显示正常/升高结果有助于统一执行年龄校正,减少影像检查同时提高检测准确率。
  • 适用人群为急诊完成D-二聚体检测的患者,原文未提及不适用人群。
  • 需注意原文为回顾性前后对照研究,结论需在其他系统中验证。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

BACKGROUND: Several previous studies have investigated the clinical utility of age-adjusted D-dimer cutoffs for diagnosing pulmonary embolism (PE).

OBJECTIVES: We performed a pre/post implementation study, using data from a mid-Atlantic healthcare system comprising 6 hospitals and 400,000 ED visits to determine whether implementing age adjusted D-dimer cutoffs reduced the number of imaging tests performed.

METHODS: Retrospective study of all patients who had a D-dimer performed during ED visits between September 2015 to September 2018. On March 21, 2017, the D-dimer upper limit of normal system-wide was increased for patients over 50 to: Age (years) x 0.01μg/mL. D-dimer results were displayed as normal or high based on automated age adjustment. EHR Chart review was performed 1.5 years prior to implementation of age-adjusted D-dimer cutoffs, as well as 1.5 years after to evaluate mortality and test accuracy characteristics such as false negative rates. Comparisons were made using chi-square testing.

RESULTS: 22,302 D-dimers were performed pre-implementation of which 10,837 (48.6%) were positive resulting in 7218 (32.3%) imaging studies. After implementation of age-adjusted d-dimer, 25,082 were performed of which 10,851 (43.2%) were positive resulting in 7017 (28.0%) imaging studies. (pre: 48.6%, post: 43.2%; p < 0.01). A significantly lower proportion of patients had a positive d-dimer (pre: 48.6%, post: 43.2%; p < 0.01) and underwent imaging post-implementation (pre: 32.3%, post: 28.0%; p < 0.05) a relative risk reduction of 13.3. This absolute risk reduction of 4.4% is associated with 1104 less scans in the post-implementation group while still increasing test accuracy from 53.7% to 59.2% (p < 0.05).

CONCLUSION: Implementation of an automated age-adjusted D-dimer positive reference value reduced CT and V/Q imaging in this population by 4.4% while increasing test accuracy in a regional, heterogeneous six-hospital system.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Dubin J, Ratay MK, Wilson M, et al. Multi-center implementation of automated age-adjusted D-dimer results reduces unnecessary PE imaging. Am J Emerg Med. 2020. PMID: 33243536. doi:10.1016/j.ajem.2020.10.067

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。