文献速递心脑血管急症复苏、休克与脓毒症

呼气末二氧化碳与心室颤动振幅谱面积对院外心脏骤停除颤结局的预测:是否同一枚硬币的两面?

End-tidal carbon dioxide (ETCO2) and ventricular fibrillation amplitude spectral area (AMSA) for shock outcome prediction in out-of-hospital cardiac arrest. Are they two sides of the same coin?
PubMed 文献 · Resuscitation · 2020-11-10
一句话结论院外心脏骤停患者中,AMSA与ETCO2均预测除颤成功和ROSC,联合模型预测准确性更高,且二者仅在ROSC患者中相关。

本研究基于Lombardia心脏骤停注册数据库中院外心脏骤停患者除颤器记录,纳入112例患者共391次除颤,计算每次除颤前1分钟ETCO2中位数(METCO2)和2秒室颤心电图AMSA值,用支持向量机建立预测模型。METCO2和AMSA单独预测除颤成功AUC分别为0.59和0.68,预测ROSC分别为0.56和0.74;联合模型预测除颤成功AUC升至0.71,预测ROSC升至0.77。二者仅在达到ROSC的患者中显著相关(rho=0.33,p=0.03)。提示联合使用可提高床旁除颤结局预测准确性。

要点

  • 在院外心脏骤停患者中,除颤前1分钟METCO2和2秒室颤AMSA均可预测除颤成功(恢复组织化节律)和ROSC,联合SVM模型预测除颤成功AUC为0.71(IQR 0.68-0.75)。
  • AMSA单独预测ROSC的AUC为0.74(IQR 0.71-0.78),优于METCO2的0.56(IQR 0.53-0.59),联合模型预测ROSC的AUC升至0.77(IQR 0.73-0.8)。
  • METCO2与AMSA仅在达到ROSC的患者中显著相关(rho=0.33,p=0.03),提示二者在预测除颤结局上并非完全冗余。
  • 本研究为注册数据库回顾性分析,样本量112例患者、391次除颤,联合模型基于支持向量机,尚未在床旁前瞻性验证。

适用人群与场景

  • 院外心脏骤停患者,数据来自Lombardia心脏骤停注册数据库中由外部除颤器记录的病例。

诊断标准与关键阈值

  • AMSA计算:对除颤前2秒滤波心电图(0.5-30 Hz)应用快速傅里叶变换,取2-48 mV.Hz范围。
  • METCO2计算:除颤前1分钟二氧化碳波形图中ETCO2的中位数。

处置流程与药物剂量

  • 原文未提及基于AMSA或METCO2的具体除颤或用药处置流程及药物剂量。

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 研究类型:基于注册数据库的回顾性分析;样本量:112例患者、391次除颤;中心数:原文未提及。
  • METCO2预测除颤成功AUC为0.59(IQR 0.56-0.62),预测ROSC AUC为0.56(IQR 0.53-0.59)。
  • AMSA预测除颤成功AUC为0.68(IQR 0.65-0.72),预测ROSC AUC为0.74(IQR 0.71-0.78)。
  • METCO2与AMSA联合SVM模型预测除颤成功AUC为0.71(IQR 0.68-0.75),预测ROSC AUC为0.77(IQR 0.73-0.8)。
  • METCO2与AMSA仅在达到ROSC的患者中显著相关(rho=0.33,p=0.03)。

证据类型、等级与局限

  • 证据类型:基于注册数据库的回顾性观察性研究。
  • 局限:原文未明确列出局限;设计本身为回顾性、单注册数据库、样本量112例,联合模型基于支持向量机,需前瞻性验证。

对床旁实践的改变

  • 本研究提示在院外心脏骤停除颤前,可同时获取METCO2和AMSA以联合预测除颤成功和ROSC,联合模型预测准确性高于单一指标。
  • AMSA单独预测ROSC的准确性高于METCO2,但二者联合预测ROSC的AUC最高(0.77)。
  • 该联合模型尚未在床旁前瞻性验证,不能直接作为临床决策阈值使用;原文未给出任何决策截断值。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

AIM: Ventricular fibrillation amplitude spectral area (AMSA) and end-tidal carbon dioxide (ETCO2) are predictors of shock success, understood as restoration of an organized rhythm, and return of spontaneous circulation (ROSC). However, little is known about their combined use. We aimed to assess the prediction accuracy when combined, and to clarify if they are correlated in out of hospital cardiac arrest' victims.

MATERIALS AND METHODS: Records acquired by external defibrillators in out-of-hospital cardiac arrest patients of the Lombardia Cardiac Arrest registry were processed. The 1-min pre-shock ETCO2 median value (METCO2) was computed from the capnogram and AMSA (2-48 mV.Hz range) computed applying the Fast Fourier Transform to a 2-second pre-shock filtered ECG interval (0.5-30 Hz). Support Vector Machine (SVM) predictive models based on METCO2, AMSA and their combination were fit; results were given as the area under the curve (AUC) of the receiver operating characteristic (ROC) curves.

RESULTS: We considered 112 patients with 391 shocks delivered. METCO2 and AMSA were predictors of shock success [AUC (IQR) of the ROC curve: 0.59 (0.56-0.62); 0.68 (0.65-0.72), respectively] and of ROSC [0.56 (0.53-0.59); 0.74 (0.71-0.78),]. Their combination in a SVM model increased the accuracy for predicting shock success [AUC (IQR) of the ROC curve: 0.71 (0.68-0.75)] and ROSC [0.77 (0.73-0.8)]. AMSA and METCO2 were significantly correlated only in patients who achieved ROSC (rho = 0.33 p = 0.03).

CONCLUSIONS: AMSA and ETCO2 predict shock success and ROSC after every shock, and their predictive power increases if combined. Notably, they were correlated only in patients who achieved ROSC.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Frigerio L, Baldi E, Aramendi E, et al. End-tidal carbon dioxide (ETCO2) and ventricular fibrillation amplitude spectral area (AMSA) for shock outcome prediction in out-of-hospital cardiac arrest. Are they two sides of the same coin? Resuscitation. 2020. PMID: 33181229. doi:10.1016/j.resuscitation.2020.10.032

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。