文献速递重症综合管理与镇静镇痛

折叠转运架在危重患者转运中的应用

[Application of folding transfer shelf in the transportation of critically ill patients].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2020-01-01
一句话结论急诊至ICU转运危重患者时,使用自研折叠转运架较常规担架降低不良事件总发生率(2.25% vs 10.23%)、缩短转运时间并提高生命体征稳定率。

该研究纳入2019年全年嘉兴市第一医院急诊转ICU的437例危重患者,按是否使用自研折叠转运架分为研究组222例与对照组215例(常规担架)。两组基线均衡。研究组生命体征稳定率高于对照组(89.19% vs 82.33%),转运时间短于对照组(6.39±1.35 vs 7.61±1.34分钟),不良转运事件总发生率低于对照组(2.25% vs 10.23%)。研究组抢救物品遗失和仪器坠落发生率均低于对照组(0% vs 2.79%,0% vs 2.33%)。结论提示折叠转运架可降低危重患者转运风险。

要点

  • 急诊转ICU使用折叠转运架者不良转运事件总发生率2.25%,低于常规担架组的10.23%(P<0.01)。
  • 折叠转运架组抢救物品遗失发生率0%,低于常规担架组的2.79%(P<0.05)。
  • 折叠转运架组仪器坠落发生率0%,低于常规担架组的2.33%(P<0.05)。
  • 折叠转运架组生命体征稳定率89.19%,高于常规担架组的82.33%(P<0.05)。
  • 折叠转运架组转运时间6.39±1.35分钟,短于常规担架组的7.61±1.34分钟(P<0.01)。

适用人群与场景

  • (本栏提炼含原文里核对不到的数值,已删除,请以原文为准)

诊断标准与关键阈值

  • 原文未提及

处置流程与药物剂量

  • 第一步:将危重患者分为使用自研折叠转运架(研究组)或使用常规担架(对照组)。
  • 第二步:使用自研折叠转运架进行急诊至ICU转运。
  • 第三步:比较两组不良事件发生率、生命体征稳定率和转运时间。
  • 原文未提及药物剂量、给药途径或目标值。

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 研究类型为单中心(嘉兴市第一医院)研究,样本量437例,研究组222例使用自研折叠转运架,对照组215例使用常规担架,两组性别、年龄、疾病状态和疾病严重程度等基线均衡。
  • 主要终点:研究组生命体征稳定率89.19% vs 对照组82.33%(P<0.05);研究组转运时间6.39±1.35分钟 vs 对照组7.61±1.34分钟(P<0.01)。
  • 研究组不良转运事件总发生率2.25% vs 对照组10.23%(P<0.01)。
  • 研究组抢救物品遗失发生率0% vs 对照组2.79%(P<0.05);研究组仪器坠落发生率0% vs 对照组2.33%(P<0.05)。

证据类型、等级与局限

  • 证据类型:单中心研究(原文明确为嘉兴市第一医院单家医院),非随机分组(按是否使用折叠转运架分组)。
  • 原文未述局限性。

对床旁实践的改变

  • 对于急诊转ICU的危重患者,使用自研折叠转运架与常规担架相比,可降低不良转运事件总发生率、抢救物品遗失率和仪器坠落率,并提高生命体征稳定率、缩短转运时间。
  • 原文未提及适用与不适用人群的进一步限定,也未提及常见陷阱。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

OBJECTIVE: To explore the application of folding transfer shelf in the transportation of critically ill patients.

METHODS: Patients transferred from the emergency department to the intensive care unit (ICU) admitted to the First Hospital of Jiaxing from January 1st to December 31st in 2019 were enrolled. The patients were divided into study group and control group by whether or not using the self-developed folding transfer shelf. The incidence of adverse events, the stability rate of vital signs and the transport time were compared between the two group.

RESULTS: A total of 437 patients were enrolled in the study, with 222 in the study group (which used the self-developed folding transfer shelf) and 215 in the control group (which used the conventional stretcher). The baseline data such as gender, age, disease status and disease severity were balanced between the two groups. The stability rate of vital signs in the study group was higher than that in the control group (89.19% vs. 82.33%, P < 0.05). The transfer time in the study group was shorter than that in the control group (minutes: 6.39±1.35 vs. 7.61±1.34, P < 0.01). The total incidence of adverse transport events in the study group was lower than that in the control group (2.25% vs. 10.23%, P < 0.01). The incidence of miscarriage of emergent materials and instrument falling in the study group were lower than those in the control group (0% vs. 2.79%, 0% vs. 2.33%, both P < 0.05).

CONCLUSIONS: The folding transfer shelf could reduce the transport risk of critical ill patients, especially the risk of miscarriage and falling of rescue instrument. The application of folding transfer shelf could regulate the management of transport, keep the vital signs of patients stable during transport, shorten the transport time, and facilitate an efficient and high-quality transport.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Wang X, Cheng J, Huang J, et al. [Application of folding transfer shelf in the transportation of critically ill patients]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2020. PMID: 33081903. doi:10.3760/cma.j.cn121430-20200310-00212

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。