视神经超声检测重型创伤性脑损伤颅内压升高的前瞻性研究
该前瞻性、盲法诊断准确性研究在神经创伤ICU连续纳入120例重型创伤性脑损伤患者,每日行视神经超声,由床旁操作者及对患者信息不知情的专家远程测量视神经鞘直径并测量视盘抬高,以同期有创颅内压大于22 mm Hg为参考标准。专家测得的最高视神经鞘直径检测颅内压大于22 mm Hg的ROC曲线下面积为0.81(0.73-0.87),视神经鞘直径大于0.72的灵敏度82%(48-98%)、特异度79%(70-86%),未达到预设的最低可接受灵敏度90%及相应特异度60%。视盘抬高大于0.04 cm的灵敏度90%(56-100%)、特异度71%(61-79%),曲线下面积0.84(0.76-0.90)。结论认为视神经鞘直径与颅内压呈中度、有统计学意义的相关,但不足以作为常规筛查试验;视盘抬高似乎有前景,需更大样本验证。
要点
- 在120例重型创伤性脑损伤患者中,专家测得的最高视神经鞘直径检测颅内压大于22 mm Hg的曲线下面积为0.81(0.73-0.87)。
- 视神经鞘直径大于0.72检测颅内压大于22 mm Hg的灵敏度为82%(48-98%)、特异度为79%(70-86%),未达到预设的最低可接受灵敏度90%及相应特异度60%。
- 视盘抬高大于0.04 cm检测颅内压大于22 mm Hg的灵敏度为90%(56-100%)、特异度为71%(61-79%),曲线下面积为0.84(0.76-0.90)。
- 视神经鞘直径预测治疗强度水平大于10的曲线下面积仅为0.51(0.42-0.60)。
- 床旁与专家测得的视神经鞘直径组内相关系数在入组50例后仅为0.16(-0.08至0.41),补救培训后其余受试者改善至0.87(0.81-0.92)。
适用人群与场景
- 连续纳入的神经创伤ICU重型创伤性脑损伤患者。
诊断标准与关键阈值
- 参考标准为同期有创颅内压监测,检测阳性阈值设为颅内压大于22 mm Hg。
- 预设的最低可接受灵敏度阈值为90%,相应特异度为60%。
- 同时评估视神经超声预测治疗强度水平大于10的能力。
处置流程与药物剂量
- 每日行视神经超声检查,由床旁操作者测量,并由对患者所有信息不知情的专家远程测量视神经鞘直径。
- 同时测量视盘抬高。
- 索引试验为入院期间专家远程测得的最高视神经超声值。
研究设计与关键结果
- 研究为前瞻性、盲法诊断准确性研究,共纳入120例重型创伤性脑损伤患者,在神经创伤ICU进行。
- 入组50例受试者后,床旁与专家测得的视神经鞘直径组内相关系数为0.16(-0.08至0.41),补救培训后其余受试者改善至0.87(0.81-0.92)。
- 专家测得的最高视神经鞘直径检测颅内压大于22 mm Hg的ROC曲线下面积为0.81(0.73-0.87);预测治疗强度水平大于10的曲线下面积为0.51(0.42-0.60)。
- 视神经鞘直径大于0.72检测颅内压大于22 mm Hg的灵敏度为82%(48-98%)、特异度为79%(70-86%)。
- 最高视盘抬高检测颅内压大于22 mm Hg的曲线下面积为0.84(0.76-0.90);视盘抬高大于0.04 cm的灵敏度为90%(56-100%)、特异度为71%(61-79%)。
证据类型、等级与局限
- 证据类型:前瞻性、盲法诊断准确性研究。
- 局限:视神经鞘直径未达到预设的、可证明其作为筛查试验常规临床使用的诊断准确度水平。
- 局限:视盘抬高的检测作用似乎有前景,但需更大规模研究验证。
对床旁实践的改变
- 视神经鞘直径与颅内压呈中度、有统计学意义的相关,但未达到预设的、可证明其作为常规临床筛查试验的诊断准确度水平。
- 作者认为视盘抬高的测量对检测颅内压升高似乎有前景,但需更大规模研究验证。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: Intracranial pressure monitoring plays a critical role in the management of severe traumatic brain injury. Our objective was to evaluate the accuracy of optic nerve sheath diameter as a noninvasive screening test for the detection of elevated intracranial pressure and prediction of intracranial pressure treatment intensity.
DESIGN: Prospective, blinded study of diagnostic accuracy.
SETTING: Neurotrauma ICU.
SUBJECTS: Consecutive patients with severe traumatic brain injury.
INTERVENTIONS: Optic nerve ultrasound was performed daily and optic nerve ultrasound measured at the point-of-care as well as remotely by an expert blinded to all patient details. Optic disc elevation was also measured. The index test was the highest remote-expert optic nerve ultrasound for the admission. The reference standard was the concurrent invasive intracranial pressure, with test-positivity set at intracranial pressure greater than 22 mm Hg. A priori the minimally acceptable sensitivity threshold was 90% with corresponding specificity 60%. We also evaluated the ability of optic nerve ultrasound to predict a therapeutic intensity level greater than 10.
MEASUREMENTS AND MAIN RESULTS: One hundred twenty patients were enrolled. The intraclass correlation coefficient between point of care and expert optic nerve sheath diameter after enrollment of 50 subjects was poor at 0.16 (-0.08 to 0.41) but improved to 0.87 (0.81-0.92) for the remaining subjects after remedial training. The area under the curve of the receiver operating characteristic curve of the highest expert-measured optic nerve sheath diameter to detect intracranial pressure greater than 22 mm Hg was 0.81 (0.73-0.87); area under the curve for prediction of therapeutic intensity level greater than 10 was 0.51 (0.42-0.60). Optic nerve sheath diameter greater than 0.72 demonstrated sensitivity 82% (48-98%) and specificity 79% (70-86%) for intracranial pressure greater than 22 mm Hg. The area under the curve of highest measured optic disc elevation to detect intracranial pressure greater than 22 mm Hg was 0.84 (0.76-0.90). Optic disc elevation greater than 0.04 cm attained sensitivity 90% (56-100%) and specificity 71% (61-79%).
CONCLUSIONS: While optic nerve sheath diameter demonstrated a modest, statistically significant correlation with intracranial pressure, a predetermined level of diagnostic accuracy to justify routine clinical use as a screening test was not achieved. Measurement of optic disc elevation appears promising for the detection of elevated intracranial pressure, however, verification from larger studies is necessary.
参考来源
- Agrawal D, Raghavendran K, Zhao L, et al. A Prospective Study of Optic Nerve Ultrasound for the Detection of Elevated Intracranial Pressure in Severe Traumatic Brain Injury. Crit Care Med. 2020. PMID: 33048902. doi:10.1097/CCM.0000000000004689
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。