超声检测膈肌功能障碍预测无创机械通气失败:前瞻性队列研究
前瞻性队列研究纳入60例急诊AECOPD患者,用床旁超声评估膈肌功能,以自发呼吸时膈肌增厚分数<20%定义膈肌功能障碍(DD)。DD组15例中11例(73.3%)NIV失败,无DD组45例中2例(4.4%)NIV失败。DD预测NIV失败的敏感度84.6%(95%CI 54.6-98.1)、特异度91.5%(95%CI 79.6-97.6)、阳性预测值73.3%(95%CI 51.2-87.8)、阴性预测值95.6%(95%CI 85.7-98.7)。两组住院时间无差异(p=.065),无DD组无院内死亡。
要点
- DD定义:床旁超声测得自发呼吸时膈肌增厚分数<20%;DD组15例中11例(73.3%)NIV失败,无DD组45例中2例(4.4%)NIV失败。
- DD预测NIV失败敏感度84.6%(95%CI 54.6-98.1)、特异度91.5%(95%CI 79.6-97.6)。
- DD预测NIV失败阳性预测值73.3%(95%CI 51.2-87.8)、阴性预测值95.6%(95%CI 85.7-98.7)。
- DD组与无DD组住院时间无差异(p=.065);无DD组无院内死亡。
- 急诊AECOPD患者可由有经验的临床医生用床旁超声无创评估膈肌功能以预测NIV失败。
适用人群与场景
- 因慢性阻塞性肺疾病急性加重(AECOPD)就诊于急诊科并接受无创机械通气(NIV)的患者。
诊断标准与关键阈值
- 膈肌功能障碍(DD)定义为床旁超声测得自发呼吸时膈肌增厚分数<20%。
- NIV失败为本研究主要结局;原文未提及NIV失败的具体判定标准。
处置流程与药物剂量
- 对急诊AECOPD接受NIV的患者,可由有经验的临床医生用床旁超声(POCUS)评估膈肌,检测是否存在DD(膈肌增厚分数<20%)。
- 原文未提及基于DD结果的具体处置方案或药物剂量。
红旗征与不能漏的情况
- 原文未提及
研究设计与关键结果
- 研究类型:前瞻性队列研究;样本量60例;单中心或多中心原文未提及;人群为急诊AECOPD患者。
- DD组15例中11例(73.3%)发生NIV失败,无DD组45例中2例(4.4%)发生NIV失败。
- DD预测NIV失败:敏感度84.6%(95%CI 54.6-98.1)、特异度91.5%(95%CI 79.6-97.6)、阳性预测值73.3%(95%CI 51.2-87.8)、阴性预测值95.6%(95%CI 85.7-98.7)。
- 两组住院时间无差异(p=.065);无DD组无院内死亡。
证据类型、等级与局限
- 证据类型:前瞻性队列研究;原文未给出证据等级或推荐强度。
- 原文未述局限性。
对床旁实践的改变
- 对急诊AECOPD接受NIV的患者,可用床旁超声检测膈肌增厚分数<20%的DD来预测NIV失败,DD阴性者NIV失败风险低(阴性预测值95.6%)。
- 原文未提及该策略是否改变NIV上机或撤机决策,也未提及适用与不适用人群的具体限定。
指南或共识出处
- 原文未提及
以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: This study aimed to examine the use of point-of-care ultrasonography (POCUS) in detecting diaphragmatic dysfunction (DD) and evaluate its ability to predict noninvasive mechanical ventilation (NIV) failure in patients presented to the emergency department with acute exacerbation of chronic obstructive pulmonary disease (AECOPD).
METHODS: In this prospective cohort study, the diaphragm was examined using POCUS in patients with AECOPD. DD was defined as a diaphragm thickening fraction of less than 20% during spontaneous breathing. NIV failure was the primary outcome of the study, and duration of hospital stay and in-hospital mortality were the secondary outcomes. Specificity, sensitivity, positive predictive value, and negative predictive value were estimated for predicting NIV failure in DD and evaluating the diagnostic performance of POCUS.
RESULTS: 60 patients were enrolled the study. NIV failure was found in 11 (73.3%) of 15 patients with DD and in 2 (4.4%) of 45 patients without DD. In predicting NIV failure, DD had a sensitivity of 84.6% (95% confidence interval [CI]:54.6-98.1), specificity of 91.5% (95% CI:79.6-97.6), positive predictive value of 73.3% (95% CI:51.2-87.8), and negative predictive value of 95.6% (95% CI:85.7-98.7). The duration of hospital stay was not different between groups (p = .065). No in-hospital mortality was seen in patients without DD.
CONCLUSIONS: DD has high sensitivity and specificity in predicting NIV failure in patients admitted to the emergency department with AECOPD. DD can be assessed by an experienced clinician noninvasively using POCUS in emergency departments.
参考来源
- Kocyigit H, Gunalp M, Genc S, et al. Diaphragm dysfunction detected with ultrasound to predict noninvasive mechanical ventilation failure: A prospective cohort study. Am J Emerg Med. 2020. PMID: 33046306. doi:10.1016/j.ajem.2020.08.014
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。