文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

COVID-19与典型ARDS的生理学和定量CT特征:匹配队列研究

Physiological and quantitative CT-scan characterization of COVID-19 and typical ARDS: a matched cohort study.
PubMed 文献 · Intensive Care Med · 2020-10-21
一句话结论COVID-19-ARDS在相同PaO2/FiO2下较典型ARDS有更高呼吸系统顺应性和肺气体容积,增加PEEP改善氧合但肺力学和死腔未改善。

结果显示,PaO2/FiO2匹配的ARDS与COVID-19-ARDS PaO2/FiO2相似(106 ± 59 mmHg)但Crs不同(39 ± 11 vs 49.9 ± 15.4 ml/cmH2O,p=0.03)。顺应性匹配的ARDS与COVID-19-ARDS Crs相似(50.1 ± 15.7 vs 49.9 ± 15.4 ml/cmH2O)但PaO2/FiO2显著更低(160 ± 62 vs 106.5 ± 59.6 mmHg,p<0.001)。三组肺重量相似但COVID-19-ARDS肺气体容积更高。PEEP从5增至15 cmH2O改善所有组氧合,但仅PaO2/FiO2匹配的ARDS肺力学和死腔改善,COVID-19-ARDS和顺应性匹配的ARDS未改善或恶化,提示复张潜力较低和/或血流再分布。

要点

  • COVID-19-ARDS在相同PaO2/FiO2下Crs高于PaO2/FiO2匹配的典型ARDS(49.9 ± 15.4 vs 39 ± 11 ml/cmH2O,p=0.03)。
  • 在相同Crs下,COVID-19-ARDS的PaO2/FiO2显著低于顺应性匹配的典型ARDS(106.5 ± 59.6 vs 160 ± 62 mmHg,p<0.001)。
  • 三组肺重量相似,但COVID-19-ARDS肺气体容积显著更高(1670 ± 791 ml vs PaO2/FiO2匹配ARDS 930 ± 644 ml和顺应性匹配ARDS 1301 ± 627 ml,p<0.05)。
  • PEEP从5增至15 cmH2O改善所有组氧合,但仅PaO2/FiO2匹配的ARDS肺力学和死腔改善,COVID-19-ARDS和顺应性匹配的ARDS未改善或恶化。
  • COVID-19-ARDS中静脉混合与无通气组织无关(p=0.75),提示低氧血症不完全由无通气组织范围所致。

适用人群与场景

  • 研究在ICU机械通气患者中进行,测量PEEP 5和15 cmH2O时的生理参数,CT扫描在PEEP 5 cmH2O时进行。

诊断标准与关键阈值

  • 原文未提及

处置流程与药物剂量

  • 原文未提及

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • PaO2/FiO2匹配的ARDS与COVID-19-ARDS PaO2/FiO2相似(106 ± 59 mmHg),但Crs不同(39 ± 11 vs 49.9 ± 15.4 ml/cmH2O,p=0.03)。
  • 顺应性匹配的ARDS与COVID-19-ARDS Crs相似(50.1 ± 15.7 vs 49.9 ± 15.4 ml/cmH2O),但PaO2/FiO2显著更低(160 ± 62 vs 106.5 ± 59.6 mmHg,p<0.001)。
  • 三组肺重量相似,COVID-19-ARDS肺气体容积显著更高(PaO2/FiO2匹配ARDS 930 ± 644 ml,COVID-19-ARDS 1670 ± 791 ml,顺应性匹配ARDS 1301 ± 627 ml,p<0.05)。
  • 静脉混合与无通气组织在PaO2/FiO2匹配ARDS和顺应性匹配ARDS中显著相关(p<0.001),但在COVID-19-ARDS中无关(p=0.75)。
  • PEEP从5增至15 cmH2O改善所有组氧合;PaO2/FiO2匹配ARDS肺力学和死腔改善,COVID-19-ARDS和顺应性匹配ARDS未改善或恶化。

证据类型、等级与局限

  • 证据类型:匹配队列研究(原文未明确标注证据等级)。
  • 局限:原文未述局限性。

对床旁实践的改变

  • 对于COVID-19-ARDS患者,在相同PaO2/FiO2下呼吸系统顺应性可能高于典型ARDS,评估时需考虑此差异。
  • 增加PEEP从5至15 cmH2O可改善COVID-19-ARDS氧合,但肺力学和死腔未改善或恶化,提示复张潜力较低和/或血流再分布。
  • COVID-19-ARDS低氧血症不完全由无通气组织范围解释,静脉混合与无通气组织无关。

指南或共识出处

  • Intensive Care Med:Physiological and quantitative CT-scan characterization of COVID-19 and typical ARDS: a matched cohort study.

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

PURPOSE: To investigate whether COVID-19-ARDS differs from all-cause ARDS.

METHODS: Thirty-two consecutive, mechanically ventilated COVID-19-ARDS patients were compared to two historical ARDS sub-populations 1:1 matched for PaO2/FiO2 or for compliance of the respiratory system. Gas exchange, hemodynamics and respiratory mechanics were recorded at 5 and 15 cmH2O PEEP. CT scan variables were measured at 5 cmH2O PEEP.

RESULTS: Anthropometric characteristics were similar in COVID-19-ARDS, PaO2/FiO2-matched-ARDS and Compliance-matched-ARDS. The PaO2/FiO2-matched-ARDS and COVID-19-ARDS populations (both with PaO2/FiO2 106 ± 59 mmHg) had different respiratory system compliances (Crs) (39 ± 11 vs 49.9 ± 15.4 ml/cmH2O, p = 0.03). The Compliance-matched-ARDS and COVID-19-ARDS had similar Crs (50.1 ± 15.7 and 49.9 ± 15.4 ml/cmH2O, respectively) but significantly lower PaO2/FiO2 for the same Crs (160 ± 62 vs 106.5 ± 59.6 mmHg, p < 0.001). The three populations had similar lung weights but COVID-19-ARDS had significantly higher lung gas volume (PaO2/FiO2-matched-ARDS 930 ± 644 ml, COVID-19-ARDS 1670 ± 791 ml and Compliance-matched-ARDS 1301 ± 627 ml, p < 0.05). The venous admixture was significantly related to the non-aerated tissue in PaO2/FiO2-matched-ARDS and Compliance-matched-ARDS (p < 0.001) but unrelated in COVID-19-ARDS (p = 0.75), suggesting that hypoxemia was not only due to the extent of non-aerated tissue. Increasing PEEP from 5 to 15 cmH2O improved oxygenation in all groups. However, while lung mechanics and dead space improved in PaO2/FiO2-matched-ARDS, suggesting recruitment as primary mechanism, they remained unmodified or worsened in COVID-19-ARDS and Compliance-matched-ARDS, suggesting lower recruitment potential and/or blood flow redistribution.

CONCLUSIONS: COVID-19-ARDS is a subset of ARDS characterized overall by higher compliance and lung gas volume for a given PaO2/FiO2, at least when considered within the timeframe of our study.

来源:Intensive Care Med,查看原文。版权归原作者所有。

参考来源

  1. Chiumello D, Busana M, Coppola S, et al. Physiological and quantitative CT-scan characterization of COVID-19 and typical ARDS: a matched cohort study. Intensive Care Med. 2020. PMID: 33089348. doi:10.1007/s00134-020-06281-2

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。