机械通气后迟发性膈肌功能障碍:拔管后10天小鼠模型研究
该研究为实验随机研究,使用C57/BL6小鼠,评估机械通气诱导的膈肌功能障碍在拔管后的早期和晚期恢复情况。小鼠通气6小时后即刻、拔管后1天或10天处死,部分接受S107治疗。结果显示通气6小时后膈肌力下降25-30%,拔管1天恢复至对照水平,但拔管10天再次较对照下降20%。兰尼碱受体在通气6小时、拔管1天和10天均呈PKA过度磷酸化、S-亚硝基化、氧化及calstabin-1耗竭;S107治疗可逆转膈肌力丧失。蛋白酶水解标志物calpain 1和2在拔管10天仍激活,但横截面积无显著变化。
要点
- 小鼠机械通气6小时后膈肌力下降25-30%,拔管1天恢复至对照水平,拔管10天再次较对照下降20%。
- 兰尼碱受体在通气6小时、拔管1天和10天均呈PKA过度磷酸化、S-亚硝基化、氧化及calstabin-1耗竭。
- 拔管后S107治疗可逆转机械通气相关的膈肌力丧失。
- calpain 1和calpain 2等蛋白酶水解标志物在拔管10天仍激活,但横截面积无显著变化。
- 总蛋白氧化在拔管1天恢复至对照水平。
适用人群与场景
- C57/BL6小鼠,机械通气6小时后拔管,评估拔管后早期(1天)和晚期(10天)膈肌功能恢复。
- 对照为麻醉6小时即刻处死或麻醉6小时恢复10天后处死的小鼠。
诊断标准与关键阈值
- 原文未提及
处置流程与药物剂量
- S107(一种稳定兰尼碱受体复合物的Rycal药物)用于拔管后治疗,可逆转机械通气相关的膈肌力丧失;原文未给出剂量、途径和频次。
红旗征与不能漏的情况
- 原文未提及
研究设计与关键结果
- 实验随机研究,C57/BL6小鼠;通气6小时组n=18,拔管后1天组n=18,拔管后10天组n=18(其中S107治疗n=5,未治疗n=16);麻醉6小时即刻处死对照组n=15,麻醉6小时恢复10天对照组n=5。
- 通气6小时后膈肌力下降25-30%,拔管1天恢复至对照水平,拔管10天再次较对照下降20%。
- 兰尼碱受体在通气6小时、拔管1天和10天均呈PKA过度磷酸化、S-亚硝基化、氧化及calstabin-1耗竭。
- 拔管后S107治疗可逆转膈肌力丧失。
- 总蛋白氧化在拔管1天恢复至对照水平;calpain 1和calpain 2在拔管10天仍激活,横截面积无显著变化。
证据类型、等级与局限
- 证据类型:实验随机研究(动物模型)。
- 原文未述局限性。
对床旁实践的改变
- 原文未提及
指南或共识出处
- Crit Care Med
以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: Mechanical ventilation is associated with primary diaphragmatic dysfunction, also termed ventilator-induced diaphragmatic dysfunction. Studies evaluating diaphragmatic function recovery after extubation are lacking. We evaluated early and late recoveries from ventilator-induced diaphragmatic dysfunction in a mouse model.
DESIGN: Experimental randomized study.
SETTING: Research laboratory.
SUBJECTS: C57/BL6 mice.
INTERVENTIONS: Six groups of C57/BL6 mice. Mice were ventilated for 6 hours and then euthanatized immediately (n = 18), or 1 (n = 18) or 10 days after extubation with (n = 5) and without S107 (n = 16) treatment. Mice euthanatized immediately after 6 hours of anesthesia (n = 15) or after 6 hours of anesthesia and 10 days of recovery (n = 5) served as controls.
MEASUREMENTS AND MAIN RESULTS: For each group, diaphragm force production, posttranslational modification of ryanodine receptor, oxidative stress, proteolysis, and cross-sectional areas were evaluated. After 6 hours of mechanical ventilation, diaphragm force production was decreased by 25-30%, restored to the control levels 1 day after extubation, and secondarily decreased by 20% 10 days after extubation compared with controls. Ryanodine receptor was protein kinase A-hyperphosphorylated, S-nitrosylated, oxidized, and depleted of its stabilizing subunit calstabin-1 6 hours after the onset of the mechanical ventilation, 1 and 10 days after extubation. Post extubation treatment with S107, a Rycal drug that stabilizes the ryanodine complex, did reverse the loss of diaphragmatic force associated with mechanical ventilation. Total protein oxidation was restored to the control levels 1 day after extubation. Markers of proteolysis including calpain 1 and calpain 2 remained activated 10 days after extubation without significant changes in cross-sectional areas.
CONCLUSIONS: We report that mechanical ventilation is associated with a late diaphragmatic dysfunction related to a structural alteration of the ryanodine complex that is reversed with the S107 treatment.
参考来源
- Dridi H, Jung B, Yehya M, et al. Late Ventilator-Induced Diaphragmatic Dysfunction After Extubation. Crit Care Med. 2020. PMID: 33009102. doi:10.1097/CCM.0000000000004569
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。