文献速递复苏、休克与脓毒症心脑血管急症重症综合管理与镇静镇痛

二维颈动脉超声检测脉搏存在与缺失的有效性评估

Assessing the validity of two-dimensional carotid ultrasound to detect the presence and absence of a pulse.
PubMed 文献 · Resuscitation · 2020-10-12
一句话结论二维颈动脉超声检测脉搏存在与缺失总体敏感度0.91、特异度0.90,低收缩压组敏感度降至0.83。

该横断面多患者多阅片者重复测量诊断研究在体外循环患者中采集颈动脉10秒视频,由重症医师判断脉搏有无,以动脉线波形为真值。共23例患者、46名医师阅片。总体敏感度0.91(95%CI 0.89-0.93),特异度0.90(95%CI 0.86-0.93);高收缩压组敏感度最高0.96(95%CI 0.93-0.98),低收缩压组最低0.83(95%CI 0.78-0.87)。作者结论认为二维颈动脉超声对脉搏有无的检测兼具敏感性与特异性。

要点

  • 总体敏感度0.91(95%CI 0.89-0.93),特异度0.90(95%CI 0.86-0.93),以动脉线波形为真值。
  • 高收缩压组(中位120 mmHg)敏感度最高0.96(95%CI 0.93-0.98)。
  • 低收缩压组(中位69 mmHg)敏感度最低0.83(95%CI 0.78-0.87)。
  • 研究在体外循环患者中采集颈总动脉10秒视频,医师需在10秒内判断脉搏是否存在。
  • 作者结论:二维颈总动脉超声检测脉搏存在与缺失兼具敏感性与特异性。

适用人群与场景

  • 接受常规体外循环手术的患者,用于采集有脉搏(高、中、低收缩压)与无脉搏(体外循环期间)状态的颈总动脉超声视频。

诊断标准与关键阈值

  • 以动脉线波形作为脉搏状态的真值标准。
  • 收缩压分组:高收缩压组>90 mmHg、中收缩压组70-90 mmHg、低收缩压组<70 mmHg。

研究设计与关键结果

  • 研究类型:横断面、多患者、多阅片者重复测量诊断研究;23例患者完成全部四次视频采集,中位年龄64岁(IQR 14),男性16例(70%),中位BMI 27。
  • 高、中、低收缩压组的中位收缩压分别为120 mmHg、83 mmHg、69 mmHg。
  • 46名医师审阅了24段视频的子集。
  • 总体敏感度0.91(95%CI 0.89-0.93),特异度0.90(95%CI 0.86-0.93)。
  • 高收缩压组敏感度0.96(95%CI 0.93-0.98),低收缩压组敏感度0.83(95%CI 0.78-0.87)。

证据类型、等级与局限

  • 证据类型:诊断准确性研究(横断面、多患者、多阅片者重复测量设计)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者结论认为二维颈总动脉超声对脉搏存在与缺失的检测兼具敏感性与特异性。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Traditional assessment of return of cardiac output in cardiac arrest by manual palpation has poor accuracy. Point of care ultrasound of a major artery has been suggested as an alternative. We conducted a diagnostic accuracy study of two-dimensional carotid ultrasound to detect the presence or absence of a pulse, using cardiopulmonary bypass patients for pulse and pulseless states.

METHODS: A cross-sectional multi-patient, multi-reader repeated measures diagnostic study was conducted. For patients undergoing routine cardiopulmonary bypass, a portable ultrasound was used to record four 10-s videos the common carotid artery, three aimed for a pulse in high (>90 mmHg), medium (70-90 mmHg) and low (<70 mmHg) systolic blood pressure (SBP) ranges, and a pulseless video was recorded on cardiopulmonary bypass. Critical care physicians viewed the videos and were asked to nominate within 10 s if a pulse was present. True pulse-status was determined via the arterial-line waveform.

RESULTS: Twenty-three patients had all four videos collected. Median patient age was 64 (IQR 14), sixteen were male (70%) and median BMI was 27. The median SBP in high-, medium- and low-SBP groups were 120 mmHg, 83 mmHg and 69 mmHg respectively. Forty-six physicians reviewed a subset of 24 videos. Overall sensitivity was 0.91 (95% confidence interval 0.89-0.93) and specificity 0.90 (95% CI 0.86-0.93). Sensitivity was highest in the high-SBP group (0.96, 95% CI 0.93-0.98) and lowest in the low-SBP group (0.83, 95% CI 0.78-0.87).

CONCLUSION: 2D ultrasound of the common carotid artery is both sensitive and specific for detection of the presence or absence of a pulse.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Sanchez S, Miller M, Asha S, et al. Assessing the validity of two-dimensional carotid ultrasound to detect the presence and absence of a pulse. Resuscitation. 2020. PMID: 33058995. doi:10.1016/j.resuscitation.2020.10.002

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。