文献速递复苏、休克与脓毒症心脑血管急症

21世纪脉搏检查:床旁超声检测颈动脉搏动的观察者间可靠性

Checking the pulse in the 21st century: Interobserver reliability of carotid pulse detection by point-of-care ultrasound.
PubMed 文献 · Am J Emerg Med · 2020-09-04
一句话结论医师解读心脏骤停患者颈动脉搏动床旁超声录像的观察者间可靠性高(Krippendorff's ⍺=0.874),但实时性能尚待研究。

该研究为基于网络的调查,纳入学术中心68名住院医师和医师,观看教程后解读15段心脏骤停患者的颈动脉搏动床旁超声录像。主要结局为观察者间可靠性,Krippendorff's ⍺=0.874(95%CI 0.869至0.879),所有亚组⍺均大于0.8。教程中位时长35秒(IQR 29),脉搏评估中位时长6秒(IQR 5),76%的评估在10秒内完成。结论认为床旁超声解读颈动脉搏动观察者间可靠性高,但实时评估性能需进一步研究。

要点

  • 68名医师解读15段心脏骤停患者颈动脉搏动床旁超声录像,观察者间可靠性Krippendorff's ⍺=0.874(95%CI 0.869至0.879)。
  • 所有亚组(按医师角色和床旁超声经验分层)的⍺均大于0.8。
  • 教程中位时长35秒(IQR 29),脉搏评估中位时长6秒(IQR 5),76%的评估在10秒内完成。
  • 研究为对预录录像的解读,进一步工作需确定床旁超声脉搏评估在心脏骤停患者实时应用中的性能。

适用人群与场景

  • 学术中心的住院医师和医师,参与解读心脏骤停患者的颈动脉搏动床旁超声录像。

研究设计与关键结果

  • 研究为基于网络的调查,68名参与者完成研究,应答率75%。
  • 参与者观看床旁超声检测颈动脉搏动的教程后,解读15段心脏骤停患者的颈动脉搏动超声录像。
  • 主要结局观察者间可靠性Krippendorff's ⍺=0.874(95%CI 0.869至0.879)。
  • 所有亚组⍺均大于0.8。
  • 教程中位时长35秒(IQR 29),脉搏评估中位时长6秒(IQR 5),76%的评估在10秒内完成。

证据类型、等级与局限

  • 证据类型:基于网络的调查研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,床旁超声解读颈动脉搏动显示高观察者间可靠性。
  • 作者指出,需进一步工作确定床旁超声脉搏评估在心脏骤停患者实时应用中的性能。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Detection of a pulse is crucial to decision-making in the care of patients who are in cardiac arrest, however, the current standard of manual pulse palpation is unreliable. An emerging alternative is the use of point-of-care ultrasound (POCUS) for direct assessment of the carotid pulse. The primary objective of this study is to determine the interobserver reliability for physician interpretation of pre-recorded point-of-care ultrasound pulse-check clips for patients who are in cardiac arrest.

METHODS: We conducted a web-based survey of residents and physicians working in an academic center. Participants were shown a tutorial demonstrating POCUS detection of the carotid pulse and then asked to interpret 15 carotid pulse ultrasound clips from patients who were in cardiac arrest. The primary outcome was interobserver reliability for carotid pulse assessment. Secondary outcomes included interobserver reliability stratified by physician role and POCUS experience, median tutorial and median pulse assessment duration. Interobserver reliability was determined by Krippendorff's ⍺.

RESULTS: 68 participants completed the study, with a response rate of 75%. There was high interobserver reliability for pulse assessment amongst all study participants (⍺ = 0.874, 95% CI 0.869 to 0.879). All sub-groups had ⍺ greater than 0.8. Median tutorial duration was 35 s (IQR 29). Median pulse assessment duration was 6 s (IQR 5) with 76% of assessments completed within 10 s.

CONCLUSION: Interpretation of the carotid pulse by POCUS showed high interobserver reliability. Further work must be done to determine the performance of POCUS pulse assessment in real-time for patients who are in cardiac arrest.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Smith DJ, Simard R, Chenkin J, et al. Checking the pulse in the 21st century: Interobserver reliability of carotid pulse detection by point-of-care ultrasound. Am J Emerg Med. 2020. PMID: 33046297. doi:10.1016/j.ajem.2020.08.072

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。