早期预警评分与qSOFA、SIRS预测急诊脓毒症准确性的比较
该回顾性研究在急诊科感染患者中比较了NEWS、MEWS、MEDS、SOS与qSOFA、SIRS预测脓毒症的准确性。主要结局为sepsis-2定义的脓毒症,次要结局为sepsis-3定义的脓毒症、住院和院内死亡。MEWS和SOS预测sepsis-2的AUC分别为0.845和0.839,优于NEWS(0.800)、qSOFA(0.657)和MEDS(0.608)。MEDS和NEWS预测sepsis-3的AUC最高(分别为0.738和0.722)。作者认为这些评分对预测脓毒症和不良结局的决策作用有限。
要点
- MEWS预测sepsis-2的AUC为0.845(95%CI 0.805-0.885),MEWS≥3时敏感度87.7%、特异度69.6%、阳性似然比2.88、阴性似然比0.18。
- SOS预测sepsis-2的AUC为0.839(95%CI 0.799-0.879),NEWS为0.800(95%CI 0.753-0.846),MEDS为0.608(95%CI 0.551-0.665),qSOFA为0.657(95%CI 0.609-0.706)。
- MEDS和NEWS预测sepsis-3的AUC最高,分别为0.738和0.722;NEWS≥7预测sepsis-3的敏感度53.3%、特异度80.9%、阳性似然比2.75、阴性似然比0.59。
- qSOFA预测院内死亡的阳性似然比最高,为3.69。
- 作者结论认为,早期预警评分、qSOFA和SIRS对急诊感染患者预测脓毒症和不良结局的决策作用有限。
适用人群与场景
- 急诊科感染患者,共777例,其中652例(83.9%)按sepsis-2定义分类为脓毒症。
诊断标准与关键阈值
- 脓毒症主要结局采用sepsis-2定义。
- 脓毒症次要结局采用sepsis-3定义。
- MEWS≥3用于预测sepsis-2定义的脓毒症。
- NEWS≥7用于预测sepsis-3定义的脓毒症。
研究设计与关键结果
- 回顾性研究,纳入急诊科感染患者777例,主要结局为sepsis-2定义的脓毒症,次要结局为sepsis-3定义的脓毒症、住院和院内死亡。
- MEWS预测sepsis-2的AUC为0.845(95%CI 0.805-0.885),SOS为0.839(95%CI 0.799-0.879),NEWS为0.800(95%CI 0.753-0.846),qSOFA为0.657(95%CI 0.609-0.706),MEDS为0.608(95%CI 0.551-0.665),所有比较P<.001。
- MEWS≥3预测sepsis-2的敏感度87.7%、特异度69.6%、阳性似然比2.88、阴性似然比0.18。
- MEDS和NEWS预测sepsis-3的AUC最高,分别为0.738和0.722;NEWS≥7预测sepsis-3的敏感度53.3%、特异度80.9%、阳性似然比2.75、阴性似然比0.59。
- qSOFA预测院内死亡的阳性似然比最高,为3.69。
证据类型、等级与局限
- 证据类型:回顾性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,早期预警评分、qSOFA和SIRS对急诊感染患者预测脓毒症和不良结局的决策作用有限。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
INTRODUCTION: The aims of this study were to evaluate the accuracy of early warnings scores including National Early Warning Score (NEWS), Modified Early Warning Score (MEWS), Mortality in Emergency Department Sepsis score (MEDS), Search Out Severity score (SOS) and compare them with quick Sequential Organ Failure Assessment (qSOFA) and Systemic Inflammatory Response Syndrome (SIRS) for detecting sepsis among infected patients at the emergency department (ED).
METHODS: A retrospective study was conducted at ED of a university hospital. Primary outcome was sepsis defined by sepsis-2 definition. Secondary outcomes were sepsis defined by sepsis-3 definition, hospital admission and in-hospital mortality.
RESULTS: A total of 652 (83.9%) from 777 infected patients were classified as sepsis by sepsis-2. MEWS and SOS outperformed other scores in predicting sepsis with the area under receiver operating characteristic curve (AUC) (95%CI) 0.845 (0.805-0.885) and 0.839 (0.799-0.879), followed by NEWS 0.800 (0.753-0.846), MEDS 0.608 (0.551-0.665) and qSOFA 0.657 (0.609-0.706) (p < .001 for all). MEWS ≥3 had a sensitivity of 87.7%, specificity of 69.6%, positive and negative likelihood ratio of 2.88 and 0.18 for predicting sepsis by sepsis-2. Whereas, MEDS and NEWS presented the highest AUC for predicting sepsis according to sepsis-3 (AUC 0.738 and 0.722). NEWS ≥7 predicted sepsis by sepsis-3 with 53.3% sensitivity, 80.9% specificity, 2.75 positive likelihood ratio (LR+) and 0.59 negative likelihood ratio. qSOFA had the highest LR+ of 3.69 for predicting hospital mortality.
CONCLUSION: The early warning scores, qSOFA and SIRS had limited decision making for predicting sepsis and adverse outcomes among infected patients.
参考来源
- Wattanasit P, Khwannimit B. Comparison the accuracy of early warning scores with qSOFA and SIRS for predicting sepsis in the emergency department. Am J Emerg Med. 2020. PMID: 33046318. doi:10.1016/j.ajem.2020.07.077
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。