文献速递复苏、休克与脓毒症

腹主动脉与交界部位止血带对猪心室颤动模型胸外按压效果的影响

Effect of the Abdominal Aortic and Junctional Tourniquet on chest compressions in a swine model of ventricular fibrillation.
PubMed 文献 · Am J Emerg Med · 2020-08-27
一句话结论在猪心室颤动模型中,AAJT虽改善颈动脉舒张压和血流,但未提高ROSC或生存率,未显示生存获益。

研究在猪心室颤动模型中评估腹主动脉与交界部位止血带(AAJT)对胸外按压效果的影响,每组6头约克夏猪,电诱导心室颤动后随机分入AAJT组或对照组,按压4分钟后若入选AAJT组则充气,总按压10分钟后进入10分钟高级生命支持阶段。结果显示两组均未实现ROSC或心律转复,AAJT组颈动脉舒张压和颈动脉血流显著更高(P=0.016和0.028),但冠状动脉灌注压和呼气末二氧化碳无显著差异。结论认为AAJT未带来生存优势,仅在放置期间观察到血流动力学改善。

要点

  • 猪心室颤动模型中,AAJT组与对照组均未实现ROSC或心律转复,AAJT未显示生存获益。
  • AAJT组颈动脉舒张压和颈动脉血流显著高于对照组(P=0.016和0.028)。
  • AAJT组与对照组在冠状动脉灌注压和呼气末二氧化碳上无显著差异。
  • AAJT在按压4分钟后充气,总按压10分钟后进入10分钟高级生命支持阶段。
  • 该研究为猪模型,每组6头,结果不能直接外推至人类临床决策。

适用人群与场景

  • 约克夏猪(每组6头),全身麻醉并置入监测设备后电诱导心室颤动,用于评估胸外按压效果。

诊断标准与关键阈值

  • 电诱导心室颤动模型;按压4分钟后入选AAJT组者充气;总按压10分钟后进入10分钟高级生命支持阶段。

处置流程与药物剂量

  • AAJT为楔形气囊装置,充气后压迫主动脉分叉处;在按压4分钟后对入选AAJT组的动物充气。

研究设计与关键结果

  • 研究为猪心室颤动模型,每组6头,比较AAJT组与对照组在胸外按压期间的血流动力学和血气指标。
  • 两组均未实现ROSC或心律转复。
  • AAJT组颈动脉舒张压显著更高(P=0.016),颈动脉血流显著更高(P=0.028)。
  • 冠状动脉灌注压和呼气末二氧化碳在两组间无显著差异。
  • 结论认为AAJT未带来生存优势,仅在放置期间观察到血流动力学改善。

证据类型、等级与局限

  • 证据类型:动物实验(猪心室颤动模型)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 该猪模型结果显示AAJT未提高ROSC或生存率,但放置期间颈动脉舒张压和血流改善,冠状动脉灌注压和呼气末二氧化碳无显著变化。
  • 原文结论未据此给出临床推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Mortality for out-of-hospital cardiac arrest is high when traditional chest compressions are used without adjuncts. The abdominal aortic and junctional tourniquet (AAJT) is a device with a wedge-shaped air bladder that occludes the aortic bifurcation, augmenting blood flow to the heart and brain. Previously, the addition of AAJT during chest compression led to an increase in rate of survival in a model of traumatic cardiac arrest.

HYPOTHESIS: This study was designed to determine if application of the AAJT would lead to more effective chest compressions as measured by improved hemodynamic parameters and an increased rate of return of spontaneous circulation (ROSC).

METHODS: Yorkshire swine (n = 6 per group) underwent general anesthesia and instrumentation. Ventricular fibrillation (Vfib) was electrically induced and animals were allocated into groups with or without the AAJT. The AAJT was inflated if selected after four minutes of compressions. Following a total of ten minutes of compressions, the animals entered into a ten-minute advanced cardiac life support phase. Hemodynamics and blood gas measurements were compared between groups.

RESULTS: ROSC or cardioversion from Vfib was not achieved in either group. The AAJT group had improved hemodynamic parameters with significantly higher carotid diastolic pressure and higher blood flow in the carotid artery (p = 0.016 and 0.028 respectively). However, no significant differences were observed with coronary perfusion pressure or end tidal CO2.

CONCLUSION: The AAJT did not confer a survival advantage during chest compressions, but hemodynamic improvements were observed while the AAJT was in place.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Hewitt CW, Pombo MA, Blough PE, et al. Effect of the Abdominal Aortic and Junctional Tourniquet on chest compressions in a swine model of ventricular fibrillation. Am J Emerg Med. 2020. PMID: 33046311. doi:10.1016/j.ajem.2020.08.075

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。