院外无脉性电活动心脏骤停的QRS波特征与患者结局
该前瞻性观察研究纳入韩国大邱地区2016年1月1日至2018年12月31日期间发生的院外无脉性电活动心脏骤停成人患者576例(中位年龄73岁,男性334例)。采用多变量logistic回归分析QRS波特征与结局的关联,QRS波各项特征分别单独(模型1)和同时(模型2)纳入分析。主要结局为出院存活,次要结局为良好神经功能结局。结果显示,QRS波振幅较高与出院存活和良好神经功能结局相关(模型1 aOR 1.077和1.106;模型2 aOR 1.084和1.123),QRS波宽度<120 ms也与出院存活和良好神经功能结局相关(模型1 aOR 3.371和4.634;模型2 aOR 3.213和5.103)。QRS波频率与结局无关联。
要点
- 院外无脉性电活动心脏骤停患者中,初始QRS波宽度<120 ms与出院存活相关(模型2 aOR 3.213,95%CI 1.568至6.584)。
- 初始QRS波宽度<120 ms与良好神经功能结局相关(模型2 aOR 5.103,95%CI 1.682至15.482)。
- 初始QRS波振幅较高与出院存活相关(模型2 aOR 1.084,95%CI 1.026至1.145)。
- 初始QRS波振幅较高与良好神经功能结局相关(模型2 aOR 1.123,95%CI 1.036至1.216)。
- QRS波频率与出院存活和良好神经功能结局均无关联。
适用人群与场景
- 年龄至少18岁、2016年1月1日至2018年12月31日期间发生院外无脉性电活动心脏骤停并录入韩国大邱急诊医疗服务登记处的患者。
研究设计与关键结果
- 前瞻性观察研究,纳入576例院外无脉性电活动心脏骤停患者(中位年龄73岁;男性334例)。
- QRS波振幅较高与出院存活相关:模型1 aOR 1.077(95%CI 1.021至0.136),模型2 aOR 1.084(95%CI 1.026至1.145)。
- QRS波振幅较高与良好神经功能结局相关:模型1 aOR 1.106(95%CI 1.029至1.190),模型2 aOR 1.123(95%CI 1.036至1.216)。
- QRS波宽度<120 ms与出院存活相关:模型1 aOR 3.371(95%CI 1.633至6.960),模型2 aOR 3.213(95%CI 1.568至6.584)。
- QRS波宽度<120 ms与良好神经功能结局相关:模型1 aOR 4.634(95%CI 1.562至13.144),模型2 aOR 5.103(95%CI 1.682至15.482)。
- QRS波频率与出院存活和良好神经功能结局均无关联。
证据类型、等级与局限
- 证据类型:前瞻性观察研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 对于院外无脉性电活动心脏骤停患者,初始QRS波振幅较高或宽度<120 ms可能提示出院存活和良好神经功能结局的概率更高。
- QRS波频率不宜用于判断院外无脉性电活动心脏骤停患者的预后。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Pulseless electrical activity (PEA) is increasingly observed in out-of-hospital cardiac arrest (OHCA), but outcomes are still poor. We aimed to assess the relationship between QRS characteristics and outcomes of patients with OHCA with initial PEA (OHCA-P).
METHODS: This prospective observational study included patients aged at least 18 years who developed OHCA-P between 1 January 2016 and 31 December 2018, and were enrolled in the Daegu Emergency Medical Services registry, South Korea. We performed multivariable logistic regression analyses to identify the associations between QRS characteristics and OHCA-P outcomes, in which QRS complexes were considered separately (model 1) and simultaneously (model 2). The primary outcome was survival to hospital discharge and the secondary outcome was a favourable neurological outcome.
RESULTS: Of the 3659 patients with OHCA, 576 were enrolled (median age 73 years; 334 men). A higher QRS amplitude was associated with survival to hospital discharge and a favourable neurological outcome in model 1 (adjusted OR (aOR) 1.077 and 1.106, respectively; 95% CI 1.021 to 0.136 and 1.029 to 1.190, respectively) and model 2 (aOR 1.084 and 1.123, respectively; 95% CI 1.026 to 1.145 and 1.036 to 1.216, respectively). A QRS width of <120 ms was associated with survival to hospital discharge and a favourable neurological outcome in model 1 (aOR 3.371 and 4.634, respectively; 95% CI 1.633 to 6.960 and 1.562 to 13.144, respectively) and model 2 (aOR 3.213 and 5.103, respectively; 95% CI 1.568 to 6.584 and 1.682 to 15.482, respectively). Survival to hospital discharge and neurological outcome were not associated with QRS frequency.
CONCLUSION: OHCA-P outcomes were better when the initial QRS complex showed a higher amplitude or narrower width.
参考来源
- Kim JH, Ryoo HW, Kim JY, et al. QRS complex characteristics and patient outcomes in out-of-hospital pulseless electrical activity cardiac arrest. Emerg Med J. 2020. PMID: 33106288. doi:10.1136/emermed-2020-209623
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。