文献速递呼吸衰竭与机械通气复苏、休克与脓毒症

经气管超声确认I-gel联合气管导管引导器气管插管位置

Transtracheal ultrasonographic confirmation of endotracheal intubation using I-gel and an endotracheal tube introducer.
PubMed 文献 · Am J Emerg Med · 2020-08-09
一句话结论经气管超声能准确识别经I-gel使用气管导管引导器的位置,敏感性100%、特异性96.3%。

本研究为前瞻性研究,纳入院外心脏骤停经I-gel置入后恢复自主循环的患者,经I-gel使用气管导管引导器行气管插管。经气管超声通过观察气管或食管内是否出现高回声伪影判断引导器位置,气管伪影以波形二氧化碳图确认,食管伪影以喉镜直视确认。106例患者中,气管伪影80例(75.5%),食管伪影26例(24.5%)。经气管超声识别引导器位置的敏感性100%(95%CI 95.4至100),特异性96.3%(95%CI 81.0至99.9),阳性预测值98.7%(95%CI 92.0至99.8),阴性预测值100%(95%CI 94.8至99.9)。

要点

  • 院外心脏骤停经I-gel置入后恢复自主循环的患者,经气管超声识别引导器位置敏感性100%(95%CI 95.4至100)。
  • 经气管超声识别引导器位置特异性96.3%(95%CI 81.0至99.9),阳性预测值98.7%(95%CI 92.0至99.8)。
  • 106例中经气管超声见气管内伪影80例(75.5%),食管内伪影26例(24.5%)。
  • 气管伪影以波形二氧化碳图确认,食管伪影以喉镜直视确认。

适用人群与场景

  • 院外心脏骤停经I-gel置入后恢复自主循环、随后经I-gel使用气管导管引导器行气管插管的患者。

研究设计与关键结果

  • 前瞻性研究纳入106例患者,经气管超声见气管内引导器伪影80例(75.5%)、食管内伪影26例(24.5%)。
  • 经气管超声识别引导器位置的敏感性100%(95%CI 95.4至100),特异性96.3%(95%CI 81.0至99.9)。
  • 经气管超声识别引导器位置的阳性预测值98.7%(95%CI 92.0至99.8),阴性预测值100%(95%CI 94.8至99.9)。

证据类型、等级与局限

  • 证据类型:前瞻性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为经气管超声是经I-gel使用气管导管引导器行气管插管时识别引导器位置的准确方法。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: This study aimed to investigate the efficacy of transtracheal ultrasonography in confirming the placement of an endotracheal tube introducer during endotracheal intubation using the I-gel supraglottic airway as a guide.

METHODS: In this prospective study, endotracheal intubation using an endotracheal tube introducer through the I-gel was performed in patients with return of spontaneous circulation after I-gel insertion for out-of-hospital cardiac arrest. The introducer placement was assessed by the occurrence of hyperechoic artifacts within the trachea or esophagus in transtracheal ultrasonography. Results of ultrasonography were confirmed by waveform capnography in the case of tracheal artifacts and direct visualization by laryngoscopy in the case of esophageal artifacts.

RESULTS: One hundred and six patients were enrolled in this study. In transtracheal ultrasonography, artifacts of introducer in the trachea and esophagus were observed in 80 (75.5%) and 26 (24.5%) patients, respectively. Transtracheal ultrasonography in identifying the placement of introducers revealed a sensitivity of 100% (95% CI 95.4 to 100), specificity of 96.3% (95% CI 81.0 to 99.9), a PPV of 98.7% (95% CI 92.0 to 99.8), and a NPV of 100% (95% CI 94.8 to 99.9).

CONCLUSION: Transtracheal ultrasonography is an accurate method for identifying introducer placement during endotracheal intubation using an endotracheal tube introducer through the I-gel.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Park SY, Kim JK. Transtracheal ultrasonographic confirmation of endotracheal intubation using I-gel and an endotracheal tube introducer. Am J Emerg Med. 2020. PMID: 33046321. doi:10.1016/j.ajem.2020.07.080

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。