手动胸外按压在院前心肺复苏中能否提供有效通气
本研究在院前医疗团队处理的成人院外心脏骤停病例中,于气管插管后立即将流量传感器连接气管导管,计算插管后前30次手动胸外按压(不同时进行手动通气)产生的被动吸气潮气量。共纳入10例患者(5例女性),中位年龄64岁(IQR 56–77岁),中位按压频率111次/分(IQR 107–116次/分),中位按压深度5.6 cm(IQR 5.4–6.1 cm),手动胸外按压产生的中位吸气潮气量为20 mL(IQR 13–28 mL)。作者结论认为,单纯胸外按压在院前心脏骤停救治中似乎无法提供足够的肺泡通气。
要点
- 院前心脏骤停患者气管插管后,手动胸外按压产生的中位被动吸气潮气量仅20 mL(IQR 13–28 mL)。
- 研究纳入10例成人院外心脏骤停患者(5例女性),中位年龄64岁(IQR 56–77岁)。
- 按压质量:中位频率111次/分(IQR 107–116次/分),中位深度5.6 cm(IQR 5.4–6.1 cm)。
- 测量在插管后立即进行,仅评估前30次手动胸外按压且不同时进行手动通气。
- 作者结论:单纯胸外按压在院前心脏骤停救治中似乎无法提供足够的肺泡通气。
适用人群与场景
- 成人院外心脏骤停患者,由院前医疗团队处理,已行气管插管且为非创伤性心脏骤停者纳入。
研究设计与关键结果
- 研究类型为院前流量传感器测量研究,共纳入10例患者(5例女性),中位年龄64岁(IQR 56–77岁)。
- 中位按压频率111次/分(IQR 107–116次/分),中位按压深度5.6 cm(IQR 5.4–6.1 cm)。
- 气管插管后前30次手动胸外按压(不同时手动通气)产生的中位被动吸气潮气量为20 mL(IQR 13–28 mL)。
- 作者结论:单纯胸外按压在院前心脏骤停救治中似乎无法提供足够的肺泡通气。
证据类型、等级与局限
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,单纯胸外按压在院前心脏骤停救治中似乎无法提供足够的肺泡通气。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
INTRODUCTION: Chest compressions have been suggested to provide passive ventilation during cardiopulmonary resuscitation. Measurements of this passive ventilatory mechanism have only been performed upon arrival of out-of-hospital cardiac arrest patients in the emergency department. Lung and thoracic characteristics rapidly change following cardiac arrest, possibly limiting the effectiveness of this mechanism after prolonged resuscitation efforts. Goal of this study was to quantify passive inspiratory tidal volumes generated by manual chest compression during prehospital cardiopulmonary resuscitation.
MATERIALS AND METHODS: A flowsensor was used during adult out-of-hospital cardiac arrest cases attended by a prehospital medical team. Adult, endotracheally intubated, non-traumatic cardiac arrest patients were eligible for inclusion. Immediately following intubation, the sensor was connected to the endotracheal tube. The passive inspiratory tidal volumes generated by the first thirty manual chest compressions performed following intubation (without simultaneous manual ventilation) were calculated.
RESULTS: 10 patients (5 female) were included, median age was 64 years (IQR 56, 77 years). The median compression frequency was 111 compression per minute (IQR 107, 116 compressions per minute). The median compression depth was 5.6 cm (IQR 5.4 cm, 6.1 cm). The median inspiratory tidal volume generated by manual chest compressions was 20 mL (IQR 13, 28 mL).
CONCLUSION: Using a flowsensor, passive inspiratory tidal volumes generated by manual chest compressions during prehospital cardiopulmonary resuscitation, were quantified. Chest compressions alone appear unable to provide adequate alveolar ventilation during prehospital treatment of cardiac arrest.