文献速递重症综合管理与镇静镇痛心脑血管急症

机械通气患者应用多普勒超声心动图估测肺动脉闭塞压

Estimation of Pulmonary Artery Occlusion Pressure Using Doppler Echocardiography in Mechanically Ventilated Patients.
PubMed 文献 · Crit Care Med · 2020-01-01
一句话结论2016年ASE/EACVI指南在机械通气重症患者中估测肺动脉闭塞压不准确,49%无法判定,敏感性和特异性均为74%。

本研究汇总了法国两家大学医院三个前瞻性队列中98例同时接受肺动脉导管和超声心动图评估的机械通气重症患者,其中54%为脓毒性休克。采用2016年ASE/EACVI指南预测肺动脉闭塞压时,49%的患者无法判定;在可判定者中,预测左房压升高(II/III级舒张功能障碍)的患者仅71%实测肺动脉闭塞压≥18 mmHg,预测左房压正常(I级舒张功能障碍)的患者77%实测<18 mmHg;敏感性和特异性均为74%,与肺动脉导管的一致性为中等(Cohen's Kappa 0.48)。作者提出的替代算法中,预测肺动脉闭塞压正常的最佳超声指标为:左室射血分数≥45%时侧壁e'波>8,或左室射血分数<45%时E/A比值≤1.5。

要点

  • 在98例机械通气重症患者中,按2016年ASE/EACVI指南估测肺动脉闭塞压,49%(48/98)无法判定。
  • 指南预测肺动脉闭塞压升高的敏感性74%、特异性74%,与肺动脉导管一致性中等(Cohen's Kappa 0.48,95%CI 0.39-0.70)。
  • 预测左房压升高(II/III级舒张功能障碍)的24例中仅17例(71%)实测肺动脉闭塞压≥18 mmHg。
  • 预测左房压正常(I级舒张功能障碍)的26例中20例(77%)实测肺动脉闭塞压<18 mmHg。
  • 作者提出的替代算法中,左室射血分数≥45%时侧壁e'波>8、左室射血分数<45%时E/A比值≤1.5为预测肺动脉闭塞压正常的最佳超声指标。

适用人群与场景

  • 机械通气重症患者,来自法国两家大学医院的内外科重症监护病房,共98例(男性67%,平均年龄59±16岁,平均简化急性生理评分2为54±20),其中53例(54%)为脓毒性休克。

诊断标准与关键阈值

  • 采用2016年美国超声心动图学会(ASE)和欧洲心血管影像协会(EACVI)指南评估肺动脉闭塞压,结果分为无法判定、预测左房压升高(II/III级舒张功能障碍)和预测左房压正常(I级舒张功能障碍)。
  • 肺动脉闭塞压≥18 mmHg定义为升高,<18 mmHg定义为正常。

研究设计与关键结果

  • 研究设计为三个前瞻性队列的汇总分析,纳入98例同时接受肺动脉导管和超声心动图评估的机械通气重症患者。
  • 按2016年ASE/EACVI指南,48/98例(49%)肺动脉闭塞压预测结果为无法判定。
  • 预测左房压升高(II/III级舒张功能障碍)的24例中,17例(71%)实测肺动脉闭塞压≥18 mmHg。
  • 预测左房压正常(I级舒张功能障碍)的26例中,20例(77%)实测肺动脉闭塞压<18 mmHg。
  • 指南预测肺动脉闭塞压升高的敏感性和特异性均为74%,与肺动脉导管的一致性为中等(Cohen's Kappa 0.48,95%CI 0.39-0.70)。
  • 作者提出的替代算法中,预测肺动脉闭塞压正常的最佳超声指标为:左室射血分数≥45%时侧壁e'波>8,或左室射血分数<45%时E/A比值≤1.5。

证据类型、等级与局限

  • 证据类型:三个前瞻性队列的汇总分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,2016年ASE/EACVI指南不能准确评估机械通气重症患者的肺动脉闭塞压。
  • 作者认为,简单的多普勒测量(左室射血分数≥45%时侧壁e'波>8,或左室射血分数<45%时E/A比值≤1.5)提供了相似水平的诊断性能,且不确定性更小。

指南或共识出处

  • 2016年美国超声心动图学会(ASE)和欧洲心血管影像协会(EACVI)指南

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: Evaluation of left atrial pressure is frequently required for mechanically ventilated critically ill patients. The objective of the present study was to evaluate the 2016 American Society of Echocardiography and the European Association of Cardiovascular Imaging guidelines for assessment of the pulmonary artery occlusion pressure (a frequent surrogate of left atrial pressure) in this population.

DESIGN: A pooled analysis of three prospective cohorts of patients simultaneously assessed with a pulmonary artery catheter and echocardiography.

SETTINGS: Medical-surgical intensive care department of two university hospitals in France.

PATIENTS: Mechanically ventilated critically ill patients.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN RESULTS: Of 98 included patients (males: 67%; mean ± SD age: 59 ± 16; and mean Simplified Acute Physiology Score 2: 54 ± 20), 53 (54%) experienced septic shock. Using the 2016 American Society of Echocardiography and the European Association of Cardiovascular Imaging guidelines, the predicted pulmonary artery occlusion pressure was indeterminate in 48 of the 98 patients (49%). Of the 24 patients with an elevated predicted left atrial pressure (grade II/III diastolic dysfunction), only 17 (71%) had a pulmonary artery occlusion pressure greater than or equal to 18 mm Hg. Similarly, 20 of the 26 patients (77%) with a normal predicted left atrial pressure (grade I diastolic dysfunction) had a measured pulmonary artery occlusion pressure less than 18 mm Hg. The sensitivity and specificity of American Society of Echocardiography and the European Association of Cardiovascular Imaging guidelines for predicting elevated pulmonary artery occlusion pressure were both 74%. The agreement between echocardiography and the pulmonary artery catheter was moderate (Cohen's Kappa, 0.48; 95% CI, 0.39-0.70). In a proposed alternative algorithm, the best echocardiographic predictors of a normal pulmonary artery occlusion pressure were a lateral e'-wave greater than 8 (for a left ventricular ejection fraction ≥ 45%) or an E/A ratio less than or equal to 1.5 (for a left ventricular ejection fraction < 45%).

CONCLUSIONS: The American Society of Echocardiography and the European Association of Cardiovascular Imaging guidelines do not accurately assess pulmonary artery occlusion pressure in ventilated critically ill patients. Simple Doppler measurements gave a similar level of diagnostic performance with less uncertainly.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Brault C, Marc J, Mercado P, et al. Estimation of Pulmonary Artery Occlusion Pressure Using Doppler Echocardiography in Mechanically Ventilated Patients. Crit Care Med. 2020. PMID: 32885942. doi:10.1097/CCM.0000000000004512

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。