文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

气管造口拔管:持续高流量氧疗联合吸痰频率评估优于24小时堵管试验

High-Flow Oxygen with Capping or Suctioning for Tracheostomy Decannulation.
PubMed 文献 · N Engl J Med · 2020-01-01
一句话结论在5个ICU的330例机械通气已脱机的气管造口患者中,以吸痰频率联合持续高流量氧疗判断拔管时机,较24小时堵管试验联合间歇高流量氧疗缩短拔管时间7天,且拔管失败率无显著差异。

该非盲随机对照试验在5个ICU纳入330例已脱机的意识清醒气管造口成人患者,比较24小时堵管试验联合间歇高流量氧疗(对照组161例)与持续高流量氧疗以吸痰频率判断拔管时机(干预组169例)。主要终点为拔管时间,干预组中位6天(四分位距5–7)vs 对照组13天(四分位距11–14),绝对差7天(95%CI 5–9)。干预组肺炎和气管支气管炎发生率更低、住院时间更短,其他次要终点两组相似,拔管失败率无显著组间差异。

要点

  • 在已脱机的意识清醒气管造口成人中,以吸痰频率联合持续高流量氧疗判断拔管时机,中位拔管时间6天,较24小时堵管试验联合间歇高流量氧疗的13天缩短7天(95%CI 5–9)。
  • 干预组肺炎和气管支气管炎发生率低于对照组,住院时间更短。
  • 拔管失败率两组无显著差异,其他次要终点(脱机失败、脓毒症、多器官衰竭、ICU住院时间、ICU和住院死亡)两组相似。
  • 该策略适用于ICU内已脱机、意识清醒的气管造口成人,不适用于未脱机或意识不清者。

适用人群与场景

  • 5个ICU中已脱机机械通气的意识清醒重症成人气管造口患者,随机分为对照组161例和干预组169例。

诊断标准与关键阈值

  • 以吸痰频率作为拔管准备度的判断指标(干预组),具体阈值原文未给出。

处置流程与药物剂量

  • 对照组:进行24小时堵管试验,并给予间歇高流量氧疗。
  • 干预组:给予持续高流量氧疗,以吸痰频率作为拔管准备度指标。

研究设计与关键结果

  • 非盲随机对照试验,5个ICU,330例已脱机的意识清醒气管造口成人,平均年龄58.3±15.1岁,男性68.2%。
  • 主要终点拔管时间:干预组中位6天(四分位距5–7)vs 对照组13天(四分位距11–14),绝对差7天(95%CI 5–9)。
  • 干预组肺炎和气管支气管炎发生率更低,住院时间更短;其他次要终点两组相似,拔管失败率无显著组间差异。

证据类型、等级与局限

  • 随机对照试验(非盲),REDECAP试验(ClinicalTrials.gov NCT02512744)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 对于ICU内已脱机、意识清醒的气管造口成人,作者认为以吸痰频率联合持续高流量氧疗判断拔管时机,较24小时堵管试验联合间歇高流量氧疗可缩短拔管时间,且不增加拔管失败。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: When patients with a tracheostomy tube reach a stage in their care at which decannulation appears to be possible, it is common practice to cap the tracheostomy tube for 24 hours to see whether they can breathe on their own. Whether this approach to establishing patient readiness for decannulation leads to better outcomes than one based on the frequency of airway suctioning is unclear.

METHODS: In five intensive care units (ICUs), we enrolled conscious, critically ill adults who had a tracheostomy tube; patients were eligible after weaning from mechanical ventilation. In this unblinded trial, patients were randomly assigned either to undergo a 24-hour capping trial plus intermittent high-flow oxygen therapy (control group) or to receive continuous high-flow oxygen therapy with frequency of suctioning being the indicator of readiness for decannulation (intervention group). The primary outcome was the time to decannulation, compared by means of the log-rank test. Secondary outcomes included decannulation failure, weaning failure, respiratory infections, sepsis, multiorgan failure, durations of stay in the ICU and hospital, and deaths in the ICU and hospital.

RESULTS: The trial included 330 patients; the mean (±SD) age of the patients was 58.3±15.1 years, and 68.2% of the patients were men. A total of 161 patients were assigned to the control group and 169 to the intervention group. The time to decannulation was shorter in the intervention group than in the control group (median, 6 days [interquartile range, 5 to 7] vs. 13 days [interquartile range, 11 to 14]; absolute difference, 7 days [95% confidence interval, 5 to 9]). The incidence of pneumonia and tracheobronchitis was lower, and the duration of stay in the hospital shorter, in the intervention group than in the control group. Other secondary outcomes were similar in the two groups.

CONCLUSIONS: Basing the decision to decannulate on suctioning frequency plus continuous high-flow oxygen therapy rather than on 24-hour capping trials plus intermittent high-flow oxygen therapy reduced the time to decannulation, with no evidence of a between-group difference in the incidence of decannulation failure. (REDECAP ClinicalTrials.gov number, NCT02512744.).

来源:N Engl J Med,查看原文。版权归原作者所有。

参考来源

  1. Hernández Martínez G, Rodriguez ML, Vaquero MC, et al. High-Flow Oxygen with Capping or Suctioning for Tracheostomy Decannulation. N Engl J Med. 2020. PMID: 32905673. doi:10.1056/NEJMoa2010834

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。