文献速递复苏、休克与脓毒症

调度员辅助与自动体外除颤器引导的心肺复苏质量:一项随机模拟试验

Quality of dispatcher-assisted vs. automated external defibrillator-guided cardiopulmonary resuscitation: a randomised simulation trial.
PubMed 文献 · Eur J Emerg Med · 2021-01-01
一句话结论模拟试验中,未受训普通民众在调度员电话指导下胸外按压深度达标比例高于自动体外除颤器引导,但两组整体心肺复苏质量均差。

该随机模拟试验纳入42名未受训志愿者,随机分配至自动体外除颤器引导心肺复苏组(A组)或调度员电话辅助心肺复苏组(T组)。A组21例中20例启动心肺复苏,T组全部启动。共完成12053次胸外按压,57.6%来自A组;胸外按压深度达标比例A组15.3% vs T组31.7%(P<0.001),胸廓完全回弹比例A组66% vs T组72%(P<0.001)。自动体外除颤器建议电击91次,所有电击均实施。结论:引导式心肺复苏帮助未受训者启动复苏,但两组质量均差,电话指导改善按压深度达标率和回弹但未优化按压频率。

要点

  • 未受训普通民众在调度员电话指导下胸外按压深度达标比例为31.7%,高于自动体外除颤器引导的15.3%(P<0.001)。
  • 胸廓完全回弹比例调度员辅助组为72%,自动体外除颤器引导组为66%(P<0.001)。
  • 自动体外除颤器引导组21例中20例启动心肺复苏,调度员辅助组全部启动。
  • 自动体外除颤器建议电击91次,所有电击均实施。
  • 两组胸外按压深度达标比例均低(15.3% vs 31.7%),电话指导未优化按压频率。

适用人群与场景

  • 未受训普通民众(非专业施救者)在模拟场景中对模拟人行心肺复苏。

研究设计与关键结果

  • 随机模拟试验纳入42名未受训志愿者,随机分为自动体外除颤器引导心肺复苏组(A组,n=21)和调度员电话辅助心肺复苏组(T组,n=21)。
  • A组21例中20例启动心肺复苏,T组全部启动。
  • 共完成12053次胸外按压,其中57.6%来自A组。
  • 胸外按压深度达标比例A组15.3% vs T组31.7%(P<0.001)。
  • 胸廓完全回弹比例A组66% vs T组72%(P<0.001)。
  • 自动体外除颤器建议电击91次,所有电击均实施。

证据类型、等级与局限

  • 证据类型:随机模拟试验。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,引导式心肺复苏可帮助未受训者启动复苏操作,但两组心肺复苏质量均差;电话指导改善胸外按压深度达标比例和胸廓回弹,但未优化按压频率。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Quality of hands-only cardiopulmonary resuscitation (CPR) is an important determinant of resuscitation outcome for cardiac arrest patients cared for by lay rescuers. We designed a simulation trial to assess and compare the quality of CPR among untrained lay people under two different scenarios: automated external defibrillator (AED)-guided and dispatcher-assisted CPR.

PATIENTS AND METHODS: A simulation study was performed involving 42 volunteers selected by non-probabilistic sampling. Participants were randomized into two CPR simulation scenarios with a manikin: (A) AED-guided CPR and (T) dispatcher-assisted CPR. The quality of CPR was evaluated by metric monitoring of the chest compressions and timing of actions. Content analysis of the telephone instructions was performed by two independent researchers using a checklist.

RESULTS: CPR was started in 20 of the 21 cases in scenario A and in all cases in scenario T. In total, 12 053 chest compressions were applied, 57.6% corresponding to scenario A. The proportion of compressions that were of an adequate depth was low in both cases, 15.3% in scenario A vs. 31.7% in scenario T (P < 0.001), while complete chest recoil was allowed in 66 and 72% (P < 0.001) of compressions, respectively. The AED advised to shock 91 times, and shocks were delivered in all cases.

CONCLUSIONS: Although guided CPR helps untrained people to initiate resuscitation manoeuvres, the quality of CPR was poor in both groups. Telephone guidance improved the proportion of compressions that achieved adequate chest compression and recoil but did not optimise the compression rate.

来源:Eur J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Ballesteros-Peña S, Fernández-Aedo I, Vallejo-De la Hoz G, et al. Quality of dispatcher-assisted vs. automated external defibrillator-guided cardiopulmonary resuscitation: a randomised simulation trial. Eur J Emerg Med. 2021. PMID: 32925478. doi:10.1097/MEJ.0000000000000715

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。