文献速递复苏、休克与脓毒症呼吸衰竭与机械通气

心肺复苏相关肺水肿(CRALE):一项转化研究

Cardiopulmonary Resuscitation-associated Lung Edema (CRALE). A Translational Study.
PubMed 文献 · Am J Respir Crit Care Med · 2021-01-01
一句话结论动物与院外心脏骤停患者中,机械胸外按压较手动按压导致更明显的肺水肿、氧合和呼吸系统顺应性更差,且与右心房压波动更大相关。

该转化研究纳入猪心脏骤停复苏模型(n=12)和多中心院外心脏骤停患者队列(n=52),患者接受机械或手动胸外按压,复苏后行肺部CT定性定量评估并分析呼吸力学和气体交换。实验与临床研究中机械按压组肺重量均高于手动按压组(实验:431±127 vs 273±66,P=0.022;临床:1208±630 vs 837±306,P=0.006)。实验研究中机械按压组氧合更低(P=0.043)、呼吸系统顺应性更低(P<0.001)。机械按压组右心房压变异显著更高(54±11 vs 31±6 mm Hg,P=0.001),且与肺重量(r=0.686,P=0.026)和呼吸系统顺应性(r=-0.634,P=0.027)相关。临床队列中机械按压组异常肺密度发生率更高(37% vs 8%,P=0.018)。

要点

  • 院外心脏骤停复苏后肺CT可见心肺复苏相关肺水肿,机械胸外按压组较手动按压组更明显。
  • 临床队列机械按压组肺重量1208±630 vs 手动组837±306(P=0.006),异常肺密度发生率37% vs 8%(P=0.018)。
  • 实验研究中机械按压组氧合更低(P=0.043)、呼吸系统顺应性更低(P<0.001)。
  • 机械按压组右心房压变异54±11 vs 手动组31±6 mm Hg(P=0.001),与肺重量和呼吸系统顺应性相关。

适用人群与场景

  • 猪心脏骤停复苏模型(n=12)
  • 多中心院外心脏骤停接受机械或手动胸外按压的患者队列(n=52)

研究设计与关键结果

  • 研究类型:转化研究,包括猪心脏骤停复苏模型(n=12)和多中心院外心脏骤停患者队列(n=52),患者接受机械或手动胸外按压,复苏后行肺部CT定性定量评估并分析呼吸力学和气体交换。
  • 实验研究:机械按压组肺重量431±127 vs 手动按压组273±66(P=0.022)。
  • 临床研究:机械按压组肺重量1208±630 vs 手动按压组837±306(P=0.006)。
  • 实验研究:机械按压组氧合显著更低(P=0.043),呼吸系统顺应性显著更低(P<0.001)。
  • 实验研究:机械按压组右心房压变异54±11 vs 手动按压组31±6 mm Hg(P=0.001),右心房压变异与肺重量相关(r=0.686,P=0.026),与呼吸系统顺应性相关(r=-0.634,P=0.027)。
  • 临床研究:机械按压组异常肺密度发生率37% vs 手动按压组8%(P=0.018)。

证据类型、等级与局限

  • 证据类型:转化研究(动物实验联合多中心临床队列)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 该研究提示机械胸外按压较手动按压与更明显的复苏后肺水肿、更低的氧合和呼吸系统顺应性相关,接受机械按压的院外心脏骤停患者复苏后需评估肺水肿对氧合和呼吸力学的影响。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Rationale: Cardiopulmonary resuscitation is the cornerstone of cardiac arrest (CA) treatment. However, lung injuries associated with it have been reported.Objectives: To assess 1) the presence and characteristics of lung abnormalities induced by cardiopulmonary resuscitation and 2) the role of mechanical and manual chest compression (CC) in its development.Methods: This translational study included 1) a porcine model of CA and cardiopulmonary resuscitation (n = 12) and 2) a multicenter cohort of patients with out-of-hospital CA undergoing mechanical or manual CC (n = 52). Lung computed tomography performed after resuscitation was assessed qualitatively and quantitatively along with respiratory mechanics and gas exchanges.Measurements and Main Results: The lung weight in the mechanical CC group was higher compared with the manual CC group in the experimental (431 ± 127 vs. 273 ± 66, P = 0.022) and clinical study (1,208 ± 630 vs. 837 ± 306, P = 0.006). The mechanical CC group showed significantly lower oxygenation (P = 0.043) and respiratory system compliance (P < 0.001) compared with the manual CC group in the experimental study. The variation of right atrial pressure was significantly higher in the mechanical compared with the manual CC group (54 ± 11 vs. 31 ± 6 mm Hg, P = 0.001) and significantly correlated with lung weight (r = 0.686, P = 0.026) and respiratory system compliance (r = -0.634, P = 0.027). Incidence of abnormal lung density was higher in patients treated with mechanical compared with manual CC (37% vs. 8%, P = 0.018).Conclusions: This study demonstrated the presence of cardiopulmonary resuscitation-associated lung edema in animals and in patients with out-of-hospital CA, which is more pronounced after mechanical as opposed to manual CC and correlates with higher swings of right atrial pressure during CC.

来源:Am J Respir Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Magliocca A, Rezoagli E, Zani D, et al. Cardiopulmonary Resuscitation-associated Lung Edema (CRALE). A Translational Study. Am J Respir Crit Care Med. 2021. PMID: 32897758. doi:10.1164/rccm.201912-2454OC

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。