急诊科对胃管并发症的处理及文献回顾
鼻胃管和口胃管在急诊与重症监护中常用于给药、胃减压和肠内喂养,置入相关并发症从鼻出血、鼻窦炎到气管支气管穿孔、管结、窒息、肺吸入、气胸甚至颅内置入。本文报告一例60岁男性在急诊因口胃管置入不当发生右侧气胸,送气试验未能识别正确置管,气管导管套囊漏气成为误置线索并随后行影像学检查。作者旨在强调胃管置入的多种可能并发症,并提出联合多种床旁试验(pH检测、CO2检测、POCUS)作为影像学的替代方案,以提高识别误置管的敏感度和特异度。
要点
- 胃管/口胃管置入可致右侧气胸等严重并发症,本病例为60岁男性口胃管置入不当后发生右侧气胸。
- 本病例中送气试验未能识别正确置管,气管导管套囊漏气成为误置线索,随后行影像学检查。
- 当前临床方案将影像学检查定为金标准,但送气试验、CO2检测、抽吸液pH检测和POCUS均已应用且效用不一。
- 作者提出联合多种床旁试验(pH检测、CO2检测、POCUS)作为影像学的替代方案,以提高识别误置管的敏感度和特异度。
适用人群与场景
- 急诊和重症监护环境中需要置入鼻胃管或口胃管以给药、胃减压或肠内喂养的患者。
处置流程与药物剂量
- 当前临床方案将影像学检查定为确认胃管位置的金标准。
- 送气试验、CO2检测(呼气末二氧化碳)、抽吸液pH检测和床旁超声(POCUS)均已用于床旁评估,效用不一。
- 作者提出联合多种床旁试验(pH检测、CO2检测、POCUS)作为影像学的替代方案,以提高识别误置管的敏感度和特异度。
红旗征与不能漏的情况
- 气管支气管穿孔、管结、窒息、肺吸入、气胸和颅内置入是胃管置入相关的严重并发症。
- 本病例为60岁男性口胃管置入不当后发生右侧气胸,送气试验未能识别正确置管,气管导管套囊漏气成为误置线索。
研究设计与关键结果
- 本文为病例报告并文献回顾:一例60岁男性在急诊因口胃管置入不当发生右侧气胸,送气试验未能识别正确置管,气管导管套囊漏气成为误置线索,随后行影像学检查。
证据类型、等级与局限
- 证据类型:病例报告并文献回顾。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者提出联合多种床旁试验(pH检测、CO2检测、POCUS)作为影像学的替代方案,以提高识别误置管的敏感度和特异度。
- 本病例提示送气试验可能无法识别正确置管,气管导管套囊漏气可作为误置线索。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
Nasogastric and orogastric tubes (NGT/OGT) are commonly used in emergency and critical care settings, with indications including medicinal administration, gastric decompression, and enteral feeding. Previous studies have highlighted a variety of complications associated with tube placement. These range from minor occurrences such as nose bleeds and sinusitis, to more severe cases highlighting tracheobronchial perforation, tube knotting, asphyxia, pulmonary aspiration, pneumothorax, and even intracranial insertion. Patients who suffer from these complications face additional obstacles including increased time spent in intensive care settings, healthcare associated costs, and nosocomial infections. Various bedside tests have been developed to reduce the risk of these complications, and current clinical protocol has characterized radiographic imaging as the gold standard. However, air insufflation, CO2 detection (capnography), aspirate pH testing, and point of care ultrasound (POCUS) have all been implemented with varying degrees of utility. Here we present a case involving a 60-year-old male who was brought to the ED and suffered a right sided pneumothorax (PTX) following improper OGT placement. In this case, air insufflation was utilized, but was ineffective in detecting the properly placed tube; leakage of an endotracheal tube cuff served as a lead for misplacement while imaging was conducted. The purpose of this study is not only to highlight the numerous complications that are possible with NGT and OGT placement, but also to propose the use of multiple bedside tests (pH testing, CO2 detection, POCUS) as an alternative to radiographic imaging to increase sensitivity and specificity for detection of improperly placed tubes.
参考来源
- O'Connell F, Ong J, Donelan C, et al. Emergency department approach to gastric tube complications and review of the literature. Am J Emerg Med. 2020. PMID: 32736966. doi:10.1016/j.ajem.2020.07.038
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。