文献速递创伤与烧伤重症综合管理与镇静镇痛

使用T6健康系统移动应用程序进行电子创伤复苏记录与决策支持:一个战斗创伤中心的试点项目

Electronic trauma resuscitation documentation and decision support using T6 Health Systems Mobile Application: A combat trauma center pilot program.
PubMed 文献 · J Trauma Acute Care Surg · 2020-01-01
一句话结论在部署的战斗创伤医院中,T6移动应用程序使创伤记录完整性总体提高13%、准确率96%,提示电子记录优于手写记录。

本研究为在部署的战斗创伤医院开展的质量改进项目,评估T6健康系统移动应用程序改善战斗伤员救治数据收集的能力。对电子记录与手写记录的完整性和准确性进行头对头比较以判定非劣效性。90天试点期间共131例创伤评估,其中53例(40.5%)伤员复苏同时记录于电子应用程序。电子记录总体数据收集较手写记录增加13%,准确率96%,提示电子记录更优;入院数据、院前数据、初次评估和二次评估的电子记录完成率均显著高于纸质记录。医疗后送团队记录院前和途中救治并在创伤复苏室同步记录,使创伤团队可在同一伤员记录上继续记录,可能促成了这种优势。

要点

  • 90天试点期间共131例创伤评估,其中53例(40.5%)伤员复苏同时记录于电子应用程序。
  • 电子记录总体数据收集较手写记录增加13%,准确率96%,提示电子记录更优。
  • 电子记录完成率显著高于纸质记录:入院数据119.7%(p<0.0001)、院前116.2%(p=0.0039)、初次评估109.6%(p<0.001)、二次评估125.5%(p<0.001)。
  • 医疗后送团队先记录院前和途中救治并在创伤复苏室同步记录,使创伤团队无需根据口头报告重新记录,可能促成了电子记录的优势。

适用人群与场景

  • 部署的战斗创伤医院中接受创伤评估的伤员。

处置流程与药物剂量

  • 医疗后送团队记录院前和途中救治,随后在创伤复苏室同步记录,使创伤团队可在同一伤员记录上继续记录,无需根据口头报告重新记录。

研究设计与关键结果

  • 研究类型为质量改进项目,在部署的创伤医院进行电子记录与手写记录完整性和准确性的头对头比较以判定非劣效性。
  • 90天试点期间共131例创伤评估,其中53例(40.5%)伤员复苏同时记录于电子应用程序。
  • 比较了入院、院前、初次评估、二次评估、干预措施和趋势数据的完整性和准确性。
  • 电子记录总体数据收集较手写记录增加13%,准确率96%,提示电子记录更优。
  • 电子记录完成率显著高于纸质记录:入院数据119.7%(p<0.0001)、院前116.2%(p=0.0039)、初次评估109.6%(p<0.001)、二次评估125.5%(p<0.001)。

证据类型、等级与局限

  • 证据类型:质量改进项目,证据等级为管理类 level IV。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在部署环境中使用移动应用程序记录创伤救治数据,可提高记录的完整性和准确性,并具有提供患者特异性决策支持和实时数据分析的能力。
  • 医疗后送团队与创伤团队在同一电子记录上连续记录,可能避免因口头报告而重复记录。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The care of trauma patients in combat operations is handwritten on a five-page flow sheet. The process requires the manual scanning and uploading of paper documents to bridge the gap between electronic and paper record management. There is an urgent operational need for an information technology solution that will enable medics to better capture patient treatment information, which will improve long-term health care without impacting short-term care responsibilities.

METHODS: We conducted a process improvement project to evaluate the ability of T6 Health Systems Mobile Application to improve combat casualty care data collection at a deployed trauma hospital. We performed a head-to-head comparison of the completeness and accuracy of data capture of electronic versus handwritten records to determine noninferiority.

RESULTS: During the 90-day pilot, there were 131 trauma evaluations of which 53 casualty resuscitations (40.5%) were also documented in the electronic application. We compared completeness and accuracy of admit, prehospital, primary survey, secondary survey, interventions, and trends data. We found an overall 13% increase in data capture at 96% accuracy compared with the written record, suggesting that the electronic record was superior. Completion of electronic documentation compared with paper by section was statistically significantly higher for admitting data, 119.7% (p < 0.0001); prehospital, 116.2% (p = 0.0039); primary, 109.6% (p < 0.001); and secondary, 125.5% (p < 0.001). We also had the medical evacuation teams document prehospital and en route care and then synchronize the record in the trauma bay, allowing the trauma teams there to continue documenting on the same casualty record, likely contributing to superiority because teams did not have to redocument based on an oral report.

CONCLUSION: Our pilot program in the deployed environment demonstrated a mobile technology that actually enhanced the completeness and accuracy of paper trauma documentation that has the capability of providing patient-specific decision support and real-time data analysis.

LEVEL OF EVIDENCE: Care Management, level IV.

来源:J Trauma Acute Care Surg,查看原文。版权归原作者所有。

参考来源

  1. Angotti LM, How RA, Barnack KR, et al. Electronic trauma resuscitation documentation and decision support using T6 Health Systems Mobile Application: A combat trauma center pilot program. J Trauma Acute Care Surg. 2020. PMID: 32796437. doi:10.1097/TA.0000000000002909

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。