气管导管尺寸与急性呼吸衰竭幸存者拔管后误吸的关联:一项前瞻性队列研究
该前瞻性队列研究纳入4个学术三级医疗中心ICU中210例≥18岁、机械通气>48小时的急性呼吸衰竭患者,拔管后72小时内行软式内镜吞咽评估(给予冰、稀液体、稠液体、泥状物和饼干团),对每个食团行Penetration Aspiration Scale评分。三分之一患者(n=68)至少一个食团出现误吸(PAS≥6),13.6%(n=29)为沉默性误吸,23.8%(n=50)为非沉默性误吸。多变量分析显示,气管导管尺寸≤7.5 vs ≥8.0与任何误吸显著相关(p=0.016;OR=2.17;95%CI 1.14-4.13),并与喉肉芽组织风险相关(p=0.02)。作者结论认为较大气管导管与误吸和喉肉芽组织风险增加相关,使用较小导管可能降低拔管后误吸风险。
要点
- 急性呼吸衰竭机械通气>48小时幸存者中,拔管后72小时内软式内镜吞咽评估显示约三分之一(n=68)至少一个食团误吸(PAS≥6)。
- 多变量分析中气管导管尺寸≤7.5 vs ≥8.0与任何误吸(PAS≥6)显著相关(p=0.016;OR=2.17;95%CI 1.14-4.13)。
- 气管导管尺寸≤7.5 vs ≥8.0还与喉肉芽组织发生风险相关(p=0.02)。
- 误吸患者中13.6%(n=29)为沉默性误吸(PAS=8),23.8%(n=50)为非沉默性误吸(PAS=6或7)。
- 作者结论认为较大气管导管与误吸和喉肉芽组织风险增加相关,使用较小气管导管可能降低拔管后误吸风险。
适用人群与场景
- 纳入:≥18岁、入住ICU、经气管导管机械通气>48小时的急性呼吸衰竭幸存者,共210例,来自4个学术三级医疗中心ICU。
- 场景:ICU内拔管后72小时内行软式内镜吞咽评估。
诊断标准与关键阈值
- 误吸定义为Penetration Aspiration Scale(PAS)评分≥6。
- 非沉默性误吸定义为PAS评分=6或7;沉默性误吸定义为PAS评分=8。
- 气管导管尺寸分组:≤7.5 vs ≥8.0。
处置流程与药物剂量
- 拔管后72小时内行软式内镜吞咽评估,依次给予冰、稀液体、稠液体、泥状物和饼干团。
- 每次评估评价喉部病理,并对每个食团行PAS评分。
- 气管导管尺寸由患者的主治医师独立选择。
研究设计与关键结果
- 前瞻性队列研究,纳入4个学术三级医疗中心ICU的210例机械通气>48小时的急性呼吸衰竭幸存者。
- 三分之一患者(n=68)至少一个食团误吸(PAS≥6);13.6%(n=29)沉默性误吸;23.8%(n=50)非沉默性误吸。
- 多变量分析显示气管导管尺寸≤7.5 vs ≥8.0与任何误吸(PAS≥6)显著相关(p=0.016;OR=2.17;95%CI 1.14-4.13)。
- 气管导管尺寸≤7.5 vs ≥8.0与喉肉芽组织风险相关(p=0.02)。
证据类型、等级与局限
- 证据类型:前瞻性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 对于急性呼吸衰竭机械通气>48小时的幸存者,拔管后72小时内行软式内镜吞咽评估可识别误吸,包括沉默性误吸。
- 作者认为较大气管导管与误吸和喉肉芽组织风险增加相关,使用较小气管导管可能降低拔管后误吸风险。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: To determine whether a modifiable risk factor, endotracheal tube size, is associated with the diagnosis of postextubation aspiration in survivors of acute respiratory failure.
DESIGN: Prospective cohort study.
SETTING: ICUs at four academic tertiary care medical centers.
PATIENTS: Two hundred ten patients who were at least 18 years old, admitted to an ICU, and mechanically ventilated with an endotracheal tube for longer than 48 hours were enrolled.
INTERVENTIONS: Within 72 hours of extubation, all patients received a flexible endoscopic evaluation of swallowing examination that entailed administration of ice, thin liquid, thick liquid, puree, and cracker boluses. Patient demographics, treatment variables, and hospital outcomes were abstracted from the patient's medical records. Endotracheal tube size was independently selected by the patient's treating physicians.
MEASUREMENTS AND MAIN RESULTS: For each flexible endoscopic evaluation of swallowing examination, laryngeal pathology was evaluated, and for each bolus, a Penetration Aspiration Scale score was assigned. Aspiration (Penetration Aspiration Scale score ≥ 6) was further categorized into nonsilent aspiration (Penetration Aspiration Scale score = 6 or 7) and silent aspiration (Penetration Aspiration Scale score = 8). One third of patients (n = 68) aspirated (Penetration Aspiration Scale score ≥ 6) on at least one bolus, 13.6% (n = 29) exhibited silent aspiration, and 23.8% (n = 50) exhibited nonsilent aspiration. In a multivariable analysis, endotracheal tube size (≤ 7.5 vs ≥ 8.0) was significantly associated with patients exhibiting any aspiration (Penetration Aspiration Scale score ≥ 6) (p = 0.016; odds ratio = 2.17; 95% CI 1.14-4.13) and with risk of developing laryngeal granulation tissue (p = 0.02).
CONCLUSIONS: Larger endotracheal tube size was associated with increased risk of aspiration and laryngeal granulation tissue. Using smaller endotracheal tubes may reduce the risk of postextubation aspiration.
参考来源
- Krisciunas GP, Langmore SE, Gomez-Taborda S, et al. The Association Between Endotracheal Tube Size and Aspiration (During Flexible Endoscopic Evaluation of Swallowing) in Acute Respiratory Failure Survivors. Crit Care Med. 2020. PMID: 32804785. doi:10.1097/CCM.0000000000004554
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。