模拟延 prolonged field care 及地面和高原后送中无创 SpO2/FiO2 比值作为 PaO2/FiO2 比值替代指标的研究

Noninvasive SpO2/FiO2 ratio as surrogate for PaO2/FiO2 ratio during simulated prolonged field care and ground and high-altitude evacuation.
PubMed 文献 · J Trauma Acute Care Surg · 2020-01-01
一句话结论在无法行动脉血气分析的恶劣环境、延 prolonged field care 及空运后送中,SpO2/FiO2 比值可作为 PaO2/FiO2 比值的替代指标,用于早期识别需要肺特异性救命干预的伤员。

该研究分析 30 头麻醉猪在战斗相关创伤、复苏和重症监护干预下的数据,共进行 683 对相关性分析,比较脉搏血氧仪无创 SpO2/FiO2 比值(SFR)与 PaO2/FiO2 比值(PFR)。SFR 数值上高于 PFR,以 313 为 ARDS 截断值(PFR ≥300)。检测轻度 ARDS 的敏感性/特异性为 75%/73%(PFR 200–300 对应 SFR 252–312),中度 ARDS 为 61%/93%(PFR 100–200 对应 SFR 191–251),重度 ARDS 为 49%/97%(PFR 0–100 对应 SFR 0–190);所有组受试者工作特征曲线下面积为 0.76–0.98。作者结论认为 SFR 在无法行动脉血气分析时是有用的替代指标,可能有助于早期发现需要肺特异性救命干预的伤员,但需在危重患者中进一步研究。

要点

  • 在无法行动脉血气分析的恶劣环境、延 prolonged field care 或空运后送中,SpO2/FiO2 比值(SFR)可作为 PaO2/FiO2 比值(PFR)的替代指标。
  • SFR 数值上高于 PFR,ARDS 的 SFR 截断值为 313(对应 PFR ≥300)。
  • 检测轻度 ARDS(PFR 200–300,对应 SFR 252–312)的敏感性/特异性为 75%/73%。
  • 检测中度 ARDS(PFR 100–200,对应 SFR 191–251)的敏感性/特异性为 61%/93%。
  • 检测重度 ARDS(PFR 0–100,对应 SFR 0–190)的敏感性/特异性为 49%/97%。

适用人群与场景

  • 麻醉猪(N=30)接受战斗相关创伤、复苏和重症监护干预的数据。
  • 适用场景为无法行动脉血气分析的恶劣环境、延 prolonged field care(即无法将伤员从受伤点后送长达 72 小时)及空运后送。

诊断标准与关键阈值

  • ARDS 的 SFR 截断值为 313(对应 PFR ≥300)。
  • 轻度 ARDS:PFR 200–300 对应 SFR 252–312。
  • 中度 ARDS:PFR 100–200 对应 SFR 191–251。
  • 重度 ARDS:PFR 0–100 对应 SFR 0–190。

研究设计与关键结果

  • 研究类型为动物模型数据分析,样本为麻醉猪 N=30,共进行 683 对相关性分析。
  • SFR 数值上高于 PFR,ARDS 的 SFR 截断值为 313(PFR ≥300)。
  • 检测轻度 ARDS 的敏感性/特异性为 75%/73%(PFR 200–300 对应 SFR 252–312)。
  • 检测中度 ARDS 的敏感性/特异性为 61%/93%(PFR 100–200 对应 SFR 191–251)。
  • 检测重度 ARDS 的敏感性/特异性为 49%/97%(PFR 0–100 对应 SFR 0–190)。
  • 所有组受试者工作特征曲线下面积为 0.76–0.98。

证据类型、等级与局限

  • 证据类型:动物模型数据分析(麻醉猪)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在无法行动脉血气分析且生理条件动态变化时(如恶劣环境、延 prolonged field care 或空运后送),SFR 是 PFR 的有用替代指标,可能有助于早期发现需要肺特异性救命干预的伤员。
  • 作者指出需在危重患者中进一步研究。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Diagnosis of lung injury requires invasive blood draws to measure oxygen tension in blood. This capability is nonexistent in austere settings and during prolonged field care (PFC), that is, medical care characterized by inability to evacuate casualties from the point of injury for up to 72 hours. We analyzed pulse-oximeter-derived noninvasive SpO2 and assessed the SpO2/FiO2 ratio (SFR) as a surrogate for the PaO2/FiO2 ratio (PFR), an accepted marker of lung function. We hypothesized that SFR is a suitable surrogate for PFR in a data set from animal models of combat-relevant trauma, PFC, and aeromedical evacuation.

METHODS: Data from anesthetized swine (N = 30) subjected to combat relevant trauma, resuscitation, and critical care interventions were analyzed. Pairwise correlations and Bland-Altman and regression analyses were performed to compare PFR and SFR, based on averaged SpO2 values obtained from two monitoring devices.

RESULTS: We performed 683 pairwise correlations. SpO2/FiO2 ratio was numerically higher than PFR with a 313 cutoff values for acute respiratory distress syndrome (ARDS) (PFR ≥300). Sensitivity/specificity for detection of mild ARDS was 75%/73% with a 200 to 300 PFR range corresponding to 252 to 312 SFR range. For moderate ARDS, sensitivity/specificity was 61%/93% with a 100 to 200 PFR range corresponding to 191 to 251 SFR range. For severe ARDS, sensitivity/specificity was 49%/97% with a 0 to 100 PFR range corresponding to 0 to 190 SFR range. For all groups, areas under the receiver operating characteristic curves ranged from 0.76 to 0.98.

CONCLUSION: SpO2/FiO2 ratio is a useful surrogate for PFR when arterial blood gas testing is not available during dynamically changing physiologic conditions, for example, during austere conditions, PFC, or aeromedical evacuation, and may permit early detection of casualties in need of lung-specific life-saving interventions. Studies in critically ill humans are warranted.

来源:J Trauma Acute Care Surg,查看原文。版权归原作者所有。

参考来源

  1. Batchinsky AI, Wendorff D, Jones J, et al. Noninvasive SpO2/FiO2 ratio as surrogate for PaO2/FiO2 ratio during simulated prolonged field care and ground and high-altitude evacuation. J Trauma Acute Care Surg. 2020. PMID: 32744837. doi:10.1097/TA.0000000000002744

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。