文献速递复苏、休克与脓毒症心脑血管急症

实时反馈对成人心脏骤停患者心肺复苏质量及结局影响的系统评价与Meta分析

Effects of real-time feedback on cardiopulmonary resuscitation quality on outcomes in adult patients with cardiac arrest: A systematic review and meta-analysis.
PubMed 文献 · Resuscitation · 2020-08-02
一句话结论实时心肺复苏反馈设备能否改善自主循环恢复和短期生存取决于设备类型,便携式设备优于自动体外除颤器关联设备。

该系统评价与Meta分析检索PubMed、Embase和Cochrane CENTRAL至2020年4月30日,纳入11项研究(8项非随机和3项随机)共4851例患者,其中7项为院外心脏骤停、4项为院内心脏骤停。合并结果显示实时视听心肺复苏反馈设备对自主循环恢复(OR 1.42,95%CI 1.03-1.94,I²=80%)和出院生存(OR 1.27,95%CI 0.74-2.18,I²=86%)的效果因高异质性而未获确认。亚组分析提示异质性来源于设备类型,便携式设备研究中的患者结局优于自动体外除颤器关联设备研究。作者结论认为实时心肺复苏反馈设备能否改善患者结局取决于所用设备类型,便携式设备优于自动体外除颤器关联设备,未来需比较不同设备类型的研究以得出稳健结论。

要点

  • 纳入11项研究共4851例成人心脏骤停患者,其中院外7项、院内4项,8项非随机和3项随机研究。
  • 实时心肺复苏反馈设备对自主循环恢复的合并OR为1.42(95%CI 1.03-1.94),但异质性I²=80%、异质性检验P<0.01,合并结果未确认有效性。
  • 对出院生存的合并OR为1.27(95%CI 0.74-2.18),异质性I²=86%、异质性检验P<0.01,未达统计学显著。
  • 亚组分析显示异质性来源于设备类型,便携式设备研究中的患者结局优于自动体外除颤器关联设备研究。
  • 作者结论认为实时心肺复苏反馈设备能否改善自主循环恢复和短期生存取决于设备类型,未来需比较不同设备类型的研究以得出稳健结论。

适用人群与场景

  • 成人心脏骤停患者,包括院外心脏骤停(7项研究)和院内心脏骤停(4项研究)。

研究设计与关键结果

  • 研究类型为系统评价与Meta分析,纳入11项研究(8项非随机和3项随机),共4851例患者,其中7项记录院外心脏骤停、4项记录院内心脏骤停。
  • 主要患者结局为自主循环恢复,合并OR为1.42(95%CI 1.03-1.94,I²=80%,tau²=0.1875,异质性检验P<0.01),合并结果未确认反馈设备的有效性。
  • 次要结局包括短期生存和良好神经功能结局(脑功能分类评分1或2分),出院生存合并OR为1.27(95%CI 0.74-2.18,I²=86%,tau²=0.4048,异质性检验P<0.01)。
  • 亚组分析显示异质性来源于所用设备类型,研究便携式设备的研究中患者结局优于研究自动体外除颤器关联设备的研究。

证据类型、等级与局限

  • 证据类型为系统评价与Meta分析,纳入随机和非随机研究,方案注册号Prospero CRD42020155388。
  • 局限:自主循环恢复异质性I²=80%、异质性检验P<0.01;出院生存异质性I²=86%、异质性检验P<0.01。
  • 局限:作者结论指出未来需比较不同设备类型的研究以得出稳健结论。

对床旁实践的改变

  • 作者结论认为实时心肺复苏反馈设备能否改善自主循环恢复和短期生存取决于设备类型,便携式设备优于自动体外除颤器关联设备。
  • 作者认为未来需开展比较不同设备类型的研究以得出稳健结论。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM: To investigate the relationship between the implementation of real-time audiovisual cardiopulmonary resuscitation (CPR) feedback devices with cardiac arrest patient outcomes, such as return of spontaneous circulation (ROSC), short-term survival, and neurological outcome.

METHODS: We systematically searched PubMed, Embase, and the Cochrane CENTRAL from inception date until April 30, 2020, for eligible randomized and nonrandomized studies. Pooled odds ratio (OR) for each binary outcome was calculated using R system. The primary patient outcome was ROSC. The secondary outcomes were short-term survival and favorable neurological outcomes (cerebral performance category scores: 1 or 2).

RESULTS: We identified 11 studies (8 nonrandomized and 3 randomized studies) including 4851 patients. Seven studies documented patients with out-of-hospital cardiac arrest and four studies documented patients with in-hospital cardiac arrest. The pooled results did not confirm the effectiveness of CPR feedback device, possibly because of the high heterogeneity in ROSC (OR: 1.42, 95% CI: 1.03-1.94, I2: 80%, tau2: 0.1875, heterogeneity test p < 0.01) and survival-to-discharge (OR: 1.27, 95% CI: 0.74-2.18, I2: 86%, tau2: 0.4048, heterogeneity test p < 0.01). The subgroup analysis results revealed that heterogeneity was due to the types of devices used. Patient outcomes were more favorable in studies investigating portable devices than in studies investigating automated external defibrillator (AED)-associated devices.

CONCLUSIONS: Whether real-time CPR feedback devices can improve patient outcomes (ROSC and short-term survival) depend on the type of device used. Portable devices led to better outcomes than did AED-associated devices. Future studies comparing different types of devices are required to reach robust conclusion.

PROTOCOL REGISTRATION: Prospero registration ID CRD42020155388.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Wang SA, Su CP, Fan HY, et al. Effects of real-time feedback on cardiopulmonary resuscitation quality on outcomes in adult patients with cardiac arrest: A systematic review and meta-analysis. Resuscitation. 2020. PMID: 32755666. doi:10.1016/j.resuscitation.2020.07.024

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。