出生时功能残气量的建立:821例新生儿复苏的观察性研究
正压通气使用无呼气末正压(PEEP)的自充气袋面罩。前20次正压通气内,呼气量从3.3升至6.0 ml/kg,呼气末CO2从0.3%升至2.4%,肺顺应性从0.13升至0.19 ml/kg/mbar,心率从109升至138次/分;充气量、充气时间和峰充气压分别稳定在约12-13 ml/kg、0.45秒和36 mbar。作者认为,呼气量、呼气末CO2和心率升高伴充气/呼气量比下降及峰充气压恒定,提示功能残气量在前20次通气内建立;初始肺顺应性低,短充气时间下可能需要高于推荐的峰充气压才能输送足够潮气量。
要点
- 近足月/足月无呼吸新生儿使用无PEEP自充气袋面罩正压通气时,前20次通气内呼气量从3.3升至6.0 ml/kg,呼气末CO2从0.3%升至2.4%。
- 前20次正压通气内肺顺应性从0.13升至0.19 ml/kg/mbar,心率从109升至138次/分,充气量、充气时间和峰充气压分别稳定在约12-13 ml/kg、0.45秒和36 mbar。
- 作者认为,呼气量、呼气末CO2和心率升高伴充气/呼气量比下降及峰充气压恒定,提示功能残气量在前20次通气内建立。
- 作者指出初始肺顺应性低,短充气时间下可能需要高于推荐的峰充气压才能输送足够潮气量。
处置流程与药物剂量
- 正压通气使用无呼气末正压(PEEP)的自充气袋面罩进行。
- 前20次正压通气中,充气量稳定在约12-13 ml/kg,充气时间稳定在约0.45秒,峰充气压(PIP)稳定在约36 mbar。
研究设计与关键结果
- 观察性研究:19,587名新生儿出生,1451名接受正压通气,其中821名(出生体重中位数3180克,孕周中位数38周)接受≥20次通气且有完整数据集纳入分析。
- 前20次正压通气内,呼气量从3.3升至6.0 ml/kg,呼气末CO2从0.3%升至2.4%,肺顺应性从0.13升至0.19 ml/kg/mbar,心率从109升至138次/分。
- 充气量、充气时间和峰充气压分别稳定在约12-13 ml/kg、0.45秒和36 mbar。
证据类型、等级与局限
- 证据类型:观察性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,呼气量、呼气末CO2和心率升高伴充气/呼气量比下降及峰充气压恒定,提示使用无PEEP自充气袋面罩时功能残气量在前20次正压通气内建立。
- 作者指出初始肺顺应性低,短充气时间下可能需要高于推荐的峰充气压才能输送足够潮气量。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「适用人群与场景」「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
- 另有 2 条提炼内容因数值无法与原文逐一核对而未列出,请以原文为准。
英文原文(摘要)· 点击展开
AIM OF THE STUDY: Establishing functional residual capacity (FRC) during positive pressure ventilation (PPV) of apnoeic neonates is critical for survival. This may be difficult due to liquid-filled airways contributing to low lung compliance. The objectives were to describe initial PPV, changes in lung compliance and establishment of FRC in near-term/term neonates ≥36 weeks gestation at birth.
METHODS: Observational study of all neonatal resuscitations between 01.07.13 and 30.06.18 in a Tanzanian referral hospital. Perinatal events and characteristics were observed and recorded by trained research assistants. PPV were performed using self-inflating bag-masks without positive end-expiratory pressure (PEEP). Ventilation signals (pressure/flow), expired CO2 (ECO2) and heart rate were recorded by resuscitation monitors.
RESULTS: 19,587 neonates were born, 1451 received PPV, of these 821 of median (p25, p75) birthweight 3180 (2844, 3500) grams and gestation 38 (37, 40) weeks had ≥20 ventilations and complete datasets. There was a significant increase in expired volume (from 3.3 to 6.0 ml/kg), ECO2 (0.3-2.4%), lung compliance (0.13-0.19 ml/kg/mbar) and heart rate (109-138 beats/min) over the first 20 PPVs. Inflation volume, time, and peak inflation pressure (PIP) were stable around 12-13 ml/kg, 0.45 s, and 36 mbar, respectively.
CONCLUSIONS: The combination of increasing expired volumes, ECO2, and heart rate with decreasing inflation/expired volume ratios and constant PIP, suggests establishment of FRC during the first 20 PPVs in near-term/term neonates using a self-inflating bag-mask without PEEP, the most common device worldwide for ventilating non-breathing neonates. Initial lung compliance is low, and with short inflation times, higher than recommended PIP seem necessary to deliver adequate tidal volumes.