重型颅脑损伤患者颅内压监测置入时机的影响
该研究利用美国国家创伤数据库(NTDB)2013至2017年数据,纳入5057例接受脑室外引流或脑实质颅内压监测的重型颅脑损伤患者,采用倾向性评分匹配比较早期与晚期(6小时和12小时界值)置入颅内压监测的结局。早期置入组住院死亡率33.6%,晚期置入组30.4%(p=0.049);6小时内置入组非routine出院 disposition 发生率为92.6%,晚期置入组为94.4%(p=0.037)。晚期置入组住院时间、ICU时间和机械通气天数均显著更长,12小时界值分析结果相似。作者认为多数结局在6或12小时内置入颅内压监测时更优,可能归因于更早识别和治疗颅内高压。
要点
- 重型颅脑损伤患者6小时内置入颅内压监测者非routine出院 disposition 为92.6%,晚期置入组为94.4%(p=0.037)。
- 早期置入组住院死亡率为33.6%,晚期置入组为30.4%,差异仅达边缘统计学意义(p=0.049)。
- 晚期置入颅内压监测组住院时间、ICU时间和机械通气天数均显著长于早期置入组。
- 开颅手术(HR 1.097,95%CI 1.037-1.160)和孤立性颅内损伤(HR 1.128,95%CI 1.055-1.207)与早期置入颅内压监测相关。
- 低血压与早期置入颅内压监测呈负相关(HR 0.801,95%CI 0.725-0.884)。
适用人群与场景
- 重型颅脑损伤并接受脑室外引流或脑实质颅内压监测置入的患者,数据来自美国国家创伤数据库(NTDB)2013至2017年。
研究设计与关键结果
- 回顾性队列研究,使用美国国家创伤数据库(NTDB)2013至2017年数据,纳入5057例重型颅脑损伤患者,采用倾向性评分匹配比较早期与晚期颅内压监测置入(6小时和12小时界值)。
- 早期置入组住院死亡率为33.6%,晚期置入组为30.4%(p=0.049)。
- 6小时内置入组非routine出院 disposition 发生率为92.6%,晚期置入组为94.4%(p=0.037)。
- 晚期置入颅内压监测组住院时间、ICU时间和机械通气天数均显著长于早期置入组。
- 使用12小时界值定义晚期置入时,结果相似。
- Cox比例风险模型中,开颅手术(HR 1.097,95%CI 1.037-1.160)和孤立性颅内损伤(HR 1.128,95%CI 1.055-1.207)与早期置入颅内压监测相关;低血压与早期置入呈负相关(HR 0.801,95%CI 0.725-0.884)。
证据类型、等级与局限
- 证据类型:回顾性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,尽管死亡率与早期颅内压监测置入的关联仅达边缘统计学意义,但多数结局在到达后6或12小时内置入颅内压监测时更优,可能归因于更早识别和治疗颅内高压。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND/OBJECTIVE: Intracranial pressure (ICP) monitor placement is indicated for patients with severe traumatic brain injury (sTBI) to minimize secondary brain injury. There is little evidence to guide the optimal timing of ICP monitor placement.
METHODS: A retrospective cohort study using the National Trauma Data Bank (NTDB) from 2013 to 2017 was performed. The NTDB was queried to identify patients with sTBI who underwent external ventricular drain or intraparenchymal ICP monitor placement. Propensity score matching was used to create matched pairs of patients who underwent early compared to late ICP monitor placement using 6-h and 12-h cutoffs. The outcomes of interest were in-hospital mortality, non-routine discharge disposition, total length of stay (LOS), intensive care unit (ICU) LOS, and number of days mechanically ventilated.
RESULTS: A total of 5057 patients with sTBI were included in the study. In-hospital mortality for patients with early compared to late ICP monitor placement was 33.6% and 30.4%, respectively (p = 0.049). The incidence of non-routine disposition was 92.6% in the within 6 h group and 94.4% in the late placement group (p = 0.037). Hospital LOS, ICU LOS, and number of days mechanically ventilated were significantly greater in the late ICP monitoring group. Similar results were seen when using a 12-h cutoff for late ICP monitor placement. In the Cox proportional hazards model, craniotomy (HR 1.097, 95% CI 1.037-1.160) and isolated intracranial injury (HR 1.128, 95% CI 1.055-1.207) were associated with early ICP monitor placement. Hypotension was negatively associated with early ICP monitor placement (HR 0.801, 95% CI 0.725-0.884).
CONCLUSION: Despite a statistically marginal association between mortality and early ICP monitor placement, most outcomes were superior when ICP monitors were placed within 6 or 12 h of arrival. This may be due to earlier identification and treatment of intracranial hypertension.
参考来源
- Hoffman H, Bunch KM, Protas M, et al. The Effect of Timing of Intracranial Pressure Monitor Placement in Patients with Severe Traumatic Brain Injury. Neurocrit Care. 2021. PMID: 32504255. doi:10.1007/s12028-020-01002-5
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。