文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

中心静脉-动脉二氧化碳分压差与中心静脉血氧饱和度对危重症患者拔管失败的检测

Central Venous-to-Arterial PCO2 Difference and Central Venous Oxygen Saturation in the Detection of Extubation Failure in Critically Ill Patients.
PubMed 文献 · Crit Care Med · 2020-01-01
一句话结论在通过T管自主呼吸试验的危重症患者中,ΔPCO2变化值与ScvO2变化值是拔管失败的独立预测因子,二者联合分析诊断预测性能更优。

本研究为多中心前瞻性观察性研究,纳入3个ICU中机械通气超过48小时且耐受T管自主呼吸试验60分钟的患者75例,拔管失败18例(24%)。在自主呼吸试验前和试验开始后60分钟测量氧输送指数、氧耗指数、中心静脉血氧饱和度、中心静脉-动脉二氧化碳分压差和氧摄取率。拔管失败组氧耗指数在自主呼吸试验期间显著增加,氧摄取率增加(p=0.005)而成功组降低(p=0.001),中心静脉血氧饱和度在失败组降低而成功组升高(p=0.014),ΔPCO2在失败组升高而成功组降低(p=0.002)。ΔPCO2变化值(OR 1.02,95%CI 1.01-1.05,p=0.006)和ScvO2变化值(OR 0.84,95%CI 0.70-0.95,p=0.02)为拔管失败的独立预测因子,曲线下面积分别为0.865和0.856,联合分析曲线下面积为0.940。

要点

  • 拔管失败组ΔPCO2在自主呼吸试验期间升高、成功组降低(p=0.002);ΔPCO2变化值OR 1.02(95%CI 1.01-1.05,p=0.006)为拔管失败独立预测因子。
  • 拔管失败组ScvO2降低、成功组升高(p=0.014);ScvO2变化值OR 0.84(95%CI 0.70-0.95,p=0.02)为独立预测因子。
  • ΔPCO2变化值预测拔管失败曲线下面积0.865,ScvO2变化值曲线下面积0.856,二者联合曲线下面积0.940。
  • 拔管失败组氧摄取率增加(p=0.005)而成功组降低(p=0.001),氧耗指数在失败组显著增加。
  • 研究纳入机械通气>48小时且耐受T管自主呼吸试验60分钟的危重症患者,拔管失败定义为48小时内需要机械通气。

适用人群与场景

  • 3个ICU中机械通气超过48小时且耐受T管自主呼吸试验60分钟的危重症患者。

诊断标准与关键阈值

  • 拔管失败定义为48小时内需要机械通气。
  • 自主呼吸试验采用T管,持续60分钟。

研究设计与关键结果

  • 多中心前瞻性观察性研究,3个ICU,纳入75例患者,拔管失败18例(24%)。
  • 在自主呼吸试验前和试验开始后60分钟测量氧输送指数、氧耗指数、中心静脉血氧饱和度、中心静脉-动脉二氧化碳分压差和氧摄取率。
  • 拔管失败组氧耗指数在自主呼吸试验期间显著增加;氧输送指数在成功组和失败组均增加。
  • 氧摄取率在失败组增加(p=0.005)、成功组降低(p=0.001)。
  • 中心静脉血氧饱和度在失败组降低、成功组升高(p=0.014)。
  • ΔPCO2在拔管失败组升高、成功组降低(p=0.002)。
  • ΔPCO2变化值(OR 1.02,95%CI 1.01-1.05,p=0.006)和ScvO2变化值(OR 0.84,95%CI 0.70-0.95,p=0.02)为拔管失败的独立预测因子。
  • ΔPCO2变化值预测拔管失败曲线下面积0.865,ScvO2变化值曲线下面积0.856,二者联合曲线下面积0.940。

证据类型、等级与局限

  • 证据类型:多中心前瞻性观察性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,自主呼吸试验期间ΔPCO2变化值和中心静脉血氧饱和度是撤机结局的独立预测因子。
  • 作者认为,联合分析这两个参数可增强诊断性能,在危重症患者拔管失败检测中提供优秀的预测能力。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the ability of central venous-to-arterial carbon dioxide pressure difference, central venous oxygen saturation, and the combination of these two parameters to detect extubation failure in critically ill patients.

DESIGN: Multicentric, prospective, observational study.

SETTING: Three ICUs.

PATIENTS: All patients who received mechanical ventilation for more than 48 hours and tolerated spontaneous breathing trials with a T-piece for 60 minutes.

INTERVENTIONS: Extubation after successful spontaneous breathing trials. Extubation failure was defined as the need for mechanical ventilation within 48 hours.

MEASUREMENTS AND MAIN RESULTS: The oxygen delivery index, oxygen consumption index, central venous oxygen saturation, central venous-to-arterial carbon dioxide pressure difference, and oxygen extraction were measured immediately before spontaneous breathing trials and at 60 minutes after spontaneous breathing trials initiation. Seventy-five patients were enrolled, and extubation failure was noted in 18 (24%) patients. Oxygen consumption index increased significantly during spontaneous breathing trials in the failure group. Oxygen delivery index increased in both success and failure groups. Oxygen extraction increased in the failure group (p = 0.005) and decreased in the success group (p = 0.001). Central venous oxygen saturation decreased in the failure group and increased in the success group (p = 0.014). ΔPCO2 value increased in the extubation failure group and decreased in the success group (p = 0.002). Changes in ΔPCO2 (Δ - ΔPCO2) and central venous oxygen saturation (ΔScvO2) during spontaneous breathing trials were independently associated with extubation failure (odds ratio, 1.02; 95% CI, 1.01-1.05; p = 0.006, and odds ratio, 0.84; 95% CI, 0.70-0.95; p = 0.02, respectively). Δ - ΔPCO2 and central venous oxygen saturation could predict extubation failure with areas under the curve of 0.865 and 0.856, respectively; however, their combined areas under the curve was better at 0.940.

CONCLUSIONS: We found that Δ - ΔPCO2 and central venous oxygen saturation, during spontaneous breathing trials, were independent predictors of weaning outcomes. Combination analysis of both parameters enhanced their diagnostic performance and provided excellent predictability in extubation failure detection in critically ill patients.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Mallat J, Baghdadi FA, Mohammad U, et al. Central Venous-to-Arterial PCO2 Difference and Central Venous Oxygen Saturation in the Detection of Extubation Failure in Critically Ill Patients. Crit Care Med. 2020. PMID: 32520890. doi:10.1097/CCM.0000000000004446

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。