高热生成与33°C目标温度管理后院外心脏骤停存活者良好神经结局相关
本研究纳入2016至2018年接受33°C目标温度管理的118例成年昏迷院外心脏骤停存活者,逐分钟记录水温并计算诱导期、维持期和复温期的热指数。78例(66.1%)在6个月时神经结局不良(脑功能分级3-5级)。不良结局组三个时期的热指数均低于良好结局组。诱导期热指数、维持期热指数和复温期热指数均与不良神经结局独立相关,复温期热指数的曲线下面积最高(0.844)。
要点
- 118例接受33°C目标温度管理的院外心脏骤停存活者中,78例(66.1%)6个月神经结局不良。
- 不良结局组在诱导期、维持期和复温期的热指数均低于良好结局组。
- 复温期热指数预测不良神经结局的曲线下面积为0.844(95%CI 0.765-0.904),高于诱导期0.819和维持期0.781。
- 诱导期热指数(OR 0.916,95%CI 0.854-0.983)、维持期热指数(OR 0.082,95%CI 0.011-0.589)和复温期热指数(OR 0.009,95%CI 0.000-0.285)均与不良神经结局独立相关。
适用人群与场景
- 成人(≥18岁)昏迷的院外心脏骤停存活者,在2016至2018年间接受33°C目标温度管理。
研究设计与关键结果
- 研究类型为观察性研究,纳入118例接受33°C目标温度管理的成年昏迷院外心脏骤停存活者,主要终点为6个月时脑功能分级3-5级的不良神经结局。
- 118例中78例(66.1%)出现不良神经结局;不良结局组在诱导期、维持期和复温期的热指数均低于良好结局组。
- 诱导期、维持期和复温期热指数预测不良神经结局的曲线下面积分别为0.819(95%CI 0.737-0.883)、0.781(95%CI 0.696-0.852)和0.844(95%CI 0.765-0.904)。
- 多因素分析显示,诱导时间(OR 0.991,95%CI 0.983-0.999)、诱导期热指数(OR 0.916,95%CI 0.854-0.983)、维持期热指数(OR 0.082,95%CI 0.011-0.589)和复温期热指数(OR 0.009,95%CI 0.000-0.285)与不良神经结局相关。
证据类型、等级与局限
- 证据类型:观察性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,在33°C目标温度管理期间,热生成与院外心脏骤停存活者的神经结局独立相关,复温期热指数的预测效能高于诱导期和维持期。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
AIM: To examine the association between heat index (HI) during the induction, maintenance, and rewarming periods of targeted temperature management (TTM) and neurologic outcome in out-of-hospital cardiac arrest (OHCA) survivors.
METHODS: Adult (≥18 years) comatose OHCA survivors who underwent TTM at 33 °C between 2016 and 2018 were included. We collected data on water temperature (WT) recorded every minute during TTM. We calculated HI during induction as the inverse of the average WT × induction time (h) × 100 and HI of maintenance and rewarming as the inverse of the average WT × 100. The primary outcome was a poor neurologic outcome, based on Cerebral Performance Category 3-5 after 6 months.
RESULTS: Of the 118 included patients, 78 (66.1%) had poor outcome. Poor outcome group had lower HI during each of three periods than good outcome group. The areas under the curves for poor outcome of HI during the induction, maintenance, and rewarming periods were 0.819 (95% confidence interval [CI], 0.737-0.883), 0.781 (95% CI, 0.696-0.852), and 0.844 (95% CI, 0.765-0.904), respectively. Induction time (odds ratio [OR], 0.991; 95% CI, 0.983-0.999) and HI during induction (OR, 0.916; 95% CI, 0.854-0.983), maintenance (OR, 0.082; 95% CI, 0.011-0.589), and rewarming (OR, 0.009; 95% CI, 0.000-0.285) were associated with poor outcome.
CONCLUSIONS: Heat generation was independently associated with neurologic outcome in OHCA survivors who underwent TTM at 33 °C. The performance of HI was higher in the rewarming period than in the induction or maintenance period in association with poor neurologic outcomes.
参考来源
- Lee DH, Lee BK, Cho YS, et al. High heat generation is associated with good neurologic outcome in out-of-hospital cardiac arrest survivors underwent targeted temperature management at 33 °C. Resuscitation. 2020. PMID: 32580007. doi:10.1016/j.resuscitation.2020.06.014
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。