文献速递心脑血管急症重症综合管理与镇静镇痛

心脏骤停后P25/30皮层体感诱发电位波幅的预后价值

Prognostic Value of P25/30 Cortical Somatosensory Evoked Potential Amplitude After Cardiac Arrest.
PubMed 文献 · Crit Care Med · 2020-01-01
一句话结论靶向温度管理后心脏骤停患者,P25/30波幅降低与N20及N20-P25/30复合波相比对未苏醒的预测性能更优,AUC 0.955 vs 0.894。

该研究为前瞻性分析,纳入4家学术三级医院87例靶向温度管理后的心脏骤停幸存者,分析复温后记录的皮层体感诱发电位N20、P25/30及N20-P25/30波幅,并在自主循环恢复后72小时评估双侧瞳孔及角膜反射。出院时分为苏醒组与未苏醒组,苏醒组N20、P25/30和N20-P25/30最低波幅分别为0.17、0.45和0.73 μV,上述阈值预测未苏醒的敏感性分别为70.5%、86.4%和75.0%。P25/30波幅的AUC显著高于N20波幅(0.955 vs 0.894,p=0.036),与N20-P25/30复合波相当(0.931)。作者认为P25/30峰缺失及波幅降低可作为此类患者的预后指标。

要点

  • 87例靶向温度管理后心脏骤停幸存者,复温后记录体感诱发电位,出院时未苏醒预测中P25/30波幅阈值敏感性86.4%(95%CI 72.7-94.8%)。
  • P25/30波幅预测未苏醒的AUC为0.955(95%CI 0.912-0.998),显著高于N20波幅的0.894(95%CI 0.819-0.969),p=0.036。
  • P25/30波幅AUC与N20-P25/30复合波AUC 0.931(95%CI 0.873-0.989)相当。
  • P25/30波幅联合复苏变量或脑干反射缺失,AUC分别为0.958(95%CI 0.917-0.999)和0.974(95%CI 0.914-0.996),呈改善预后性能的趋势。
  • 作者认为P25/30峰缺失及波幅降低可作为靶向温度管理后心脏骤停患者的预后指标。

适用人群与场景

  • 靶向温度管理后的心脏骤停幸存者,来自4家学术三级医院,共87例。
  • 自主循环恢复后72小时评估双侧瞳孔及角膜反射,复温后记录体感诱发电位。

诊断标准与关键阈值

  • 以出院时是否苏醒分为苏醒组与未苏醒组。
  • 苏醒组N20、P25/30和N20-P25/30最低波幅分别为0.17、0.45和0.73 μV,作为预测未苏醒的阈值。

研究设计与关键结果

  • 前瞻性分析,4家学术三级医院,87例靶向温度管理后心脏骤停幸存者,复温后记录体感诱发电位,出院时分为苏醒组与未苏醒组。
  • N20、P25/30和N20-P25/30阈值预测未苏醒的敏感性分别为70.5%(95%CI 54.8-83.2%)、86.4%(95%CI 72.7-94.8%)和75.0%(95%CI 59.7-86.8%)。
  • P25/30波幅AUC 0.955(95%CI 0.912-0.998)显著高于N20波幅AUC 0.894(95%CI 0.819-0.969),p=0.036。
  • P25/30波幅AUC与N20-P25/30复合波AUC 0.931(95%CI 0.873-0.989)相当。
  • P25/30波幅联合复苏变量AUC 0.958(95%CI 0.917-0.999),联合脑干反射缺失AUC 0.974(95%CI 0.914-0.996),较其他体感诱发电位波幅呈改善预后性能的趋势。

证据类型、等级与局限

  • 证据类型:前瞻性分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,P25/30峰缺失及P25/30波幅降低可作为靶向温度管理后心脏骤停患者的预后指标。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to evaluate the prognostic performance of the peak amplitude of P25/30 cortical somatosensory evoked potentials in predicting nonawakening in targeted temperature management-treated cardiac arrest patients.

DESIGN: Prospective analysis.

SETTING: Four academic tertiary care hospitals.

PATIENTS: Eighty-seven cardiac arrest survivors after targeted temperature management.

INTERVENTIONS: Analysis of the amplitude of P25/30.

MEASUREMENTS AND MAIN RESULTS: In all participants, somatosensory evoked potentials were recorded after rewarming, and bilaterally absent pupillary and corneal reflexes were evaluated at 72 hours after the return of spontaneous circulation. We analyzed the amplitudes of the N20 and P25/30 peaks and the N20-P25/30 complex in cortical somatosensory evoked potentials. Upon hospital discharge, 87 patients were dichotomized into the awakening and nonawakening groups. The lowest amplitudes of N20, P25/30, and N20-P25/30 in the awakening patients were 0.17, 0.45, and 0.73 μV, respectively, and these thresholds showed a sensitivity of 70.5% (95% CI, 54.8-83.2%), 86.4% (95% CI, 72.7-94.8%), and 75.0% (95% CI, 59.7-86.8%), respectively, for nonawakening. The area under the curve of the P25/30 amplitude was significantly higher than that of the N20 amplitude (0.955 [95% CI, 0.912-0.998] vs 0.894 [95% CI, 0.819-0.969]; p = 0.036) and was comparable with that of the N20-P25/30 amplitude (0.931 [95% CI, 0.873-0.989]). Additionally, adding resuscitation variables or an absent brainstem reflex to the P25/30 amplitude showed a trend toward improving prognostic performance compared with the use of other somatosensory evoked potential amplitudes (area under the curve, 0.958; 95% CI, 0.917-0.999 and area under the curve, 0.974; 95% CI, 0.914-0.996, respectively).

CONCLUSIONS: Our results provide evidence that the absence of the P25/30 peak and a reduction in the P25/30 amplitude may be considered prognostic indicators in these patients.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Oh SH, Oh JS, Jung HH, et al. Prognostic Value of P25/30 Cortical Somatosensory Evoked Potential Amplitude After Cardiac Arrest. Crit Care Med. 2020. PMID: 32568854. doi:10.1097/CCM.0000000000004460

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。