文献速递创伤与烧伤复苏、休克与脓毒症呼吸衰竭与机械通气

10G与14G静脉导管治疗张力性气胸及张力性无脉电活动的比较:大号仍更优

Comparison of 10- versus 14-gauge angiocatheter for treatment of tension pneumothorax and tension-induced pulseless electrical activity with hemorrhagic shock: Bigger is still better.
PubMed 文献 · J Trauma Acute Care Surg · 2020-01-01
一句话结论在30%失血性休克猪模型中,10G静脉导管对张力性无脉电活动的复苏成功率显著高于14G(87% vs 48%,P=0.006)。

本研究在38只成年约克夏猪中,先控制性失血30%估计血容量,再向胸腔注入二氧化碳诱发张力性气胸(tPTX,心输出量下降50%)或张力性无脉电活动(tPEA,动脉波形消失且平均动脉压<20 mmHg),随机使用10G或14G静脉导管减压并维持持续漏气。tPTX模型中10G成功复苏90%、14G为80%(P=0.350);tPEA模型中10G成功87%、14G仅48%(P=0.006)。作者认为10G导管在失血背景下对tPEA后自主循环恢复明显优于14G,支持使用更大口径装置。

要点

  • 在30%失血性休克猪模型中,tPEA后10G静脉导管复苏成功87%,14G仅48%,差异有统计学意义(P=0.006)。
  • tPTX模型中10G成功复苏90%、14G为80%,两者无显著差异(P=0.350)。
  • tPTX定义为心输出量下降50%;tPEA定义为动脉波形消失且平均动脉压<20 mmHg。
  • 成功复苏tPTX定义为收缩压恢复至基线的80%;tPEA后自主循环恢复定义为平均动脉压>20 mmHg。
  • 证据等级为治疗性研究II级,作者认为结果支持在多发伤中使用更大口径装置以快速缓解tPTX。

适用人群与场景

  • 38只成年约克夏猪,先经历控制性失血使失血量达30%估计血容量,再诱发张力性气胸或张力性无脉电活动。

诊断标准与关键阈值

  • 张力性气胸(tPTX)定义为心输出量下降50%。
  • 张力性无脉电活动(tPEA)定义为动脉波形消失且平均动脉压<20 mmHg。
  • tPTX成功复苏定义为收缩压恢复至基线的80%。
  • tPEA后自主循环恢复定义为平均动脉压>20 mmHg。

处置流程与药物剂量

  • 对患侧胸腔使用随机分配的14G或10G静脉导管减压,减压后维持持续漏气。

研究设计与关键结果

  • 研究类型为动物实验,38只成年约克夏猪共进行80次tPTX事件和50次tPEA事件,动物与装置间基线特征无显著差异。
  • tPTX模型中10G静脉导管成功复苏90%的事件,14G成功复苏80%(P=0.350)。
  • tPEA模型中10G静脉导管成功复苏87%的事件,14G仅成功复苏48%(P=0.006)。

证据类型、等级与局限

  • 证据类型为动物实验(治疗性研究),证据等级为II级。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在30%失血背景下,10G静脉导管对tPEA后自主循环恢复明显优于14G静脉导管,支持使用更大口径装置以快速缓解tPTX,尤其在多发伤中。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Little is known regarding the effect of hemorrhagic shock on the diagnosis and treatment of tension pneumothorax (tPTX). Recently, the Tactical Combat Casualty Care guidelines included the 10-gauge angiocatheter (10-g AC) as an acceptable alternative to the 14-g AC. This study sought to compare these two devices for decompression of tPTX and rescue from tension-induced pulseless electric activity (tPEA) in the setting of a concomitant 30% estimated blood volume hemorrhage.

METHODS: Following a controlled hemorrhage, carbon dioxide was insufflated into the chest to induce either tPTX or tPEA. Tension pneumothorax was defined as a reduction in cardiac output by 50%, and tPEA was defined as a loss of arterial waveform with mean arterial pressure less than 20 mm Hg. The affected hemithorax was decompressed using a randomized 14-g AC or 10-g AC while a persistent air leak was maintained after decompression. Successful rescue from tPTX was defined as 80% recovery of baseline systolic blood pressure, while successful return of spontaneous circulation following tPEA was defined as a mean arterial pressure greater than 20 mm Hg. Primary outcome was success of device.

RESULTS: Eighty tPTX and 50 tPEA events were conducted in 38 adult Yorkshire swine. There were no significant differences in the baseline characteristics between animals or devices. In the tPTX model, the 10-g AC successfully rescued 90% of events, while 14-g AC rescued 80% of events (p = 0.350). In the tPEA model, the 10-g AC rescued 87% of events while the 14 AC rescued only 48% of events (p = 0.006).

CONCLUSION: The 10-g AC was vastly superior to the 14-g AC for return of spontaneous circulation following tPEA in the setting of 30% hemorrhage. These findings further support the importance of larger caliber devices that facilitate rapid recovery from tPTX, particularly in the setting of polytrauma.

LEVEL OF EVIDENCE: Therapeutic, level II.

来源:J Trauma Acute Care Surg,查看原文。版权归原作者所有。

参考来源

  1. Norris EA, McEvoy CS, Leatherman ML, et al. Comparison of 10- versus 14-gauge angiocatheter for treatment of tension pneumothorax and tension-induced pulseless electrical activity with hemorrhagic shock: Bigger is still better. J Trauma Acute Care Surg. 2020. PMID: 32366761. doi:10.1097/TA.0000000000002724

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。