文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

膈肌起搏改善急性颈段脊髓损伤的呼吸力学

Diaphragm pacing improves respiratory mechanics in acute cervical spinal cord injury.
PubMed 文献 · J Trauma Acute Care Surg · 2020-01-01
一句话结论回顾性倾向评分匹配研究显示,急性颈段脊髓损伤患者行膈肌起搏植入后自发潮气量增加、机械通气脱机时间缩短。

该研究为回顾性综述,纳入2005年1月至2017年5月急性颈段脊髓损伤患者,按年龄、损伤严重度评分、机械通气天数、住院时长和气管切开需求进行倾向评分匹配,比较接受膈肌起搏植入(DPS)与未接受DPS者的呼吸力学和脱机时间。2011年7月至2017年5月间37例DPS患者与34例未接受DPS者匹配。DPS后自发潮气量较未DPS组显著增加(+88 mL vs -13 mL,p=0.004),DPS后中位脱机时间显著缩短(10天 vs 29天,p<0.001),出院前脱机率两组无差异。多因素线性回归显示DPS与脱机天数减少和自发潮气量增加相关。作者结论认为DPS可改善自发潮气量并缩短脱机时间,但需前瞻性对照研究明确临床获益和潜在成本节约。

要点

  • 急性颈段脊髓损伤患者行DPS后自发潮气量较未DPS组显著增加(+88 mL vs -13 mL,p=0.004)。
  • DPS后中位脱机时间显著短于未DPS组(10天 vs 29天,p<0.001)。
  • 出院前脱机率两组无差异。
  • 多因素线性回归显示DPS与脱机天数减少和自发潮气量增加独立相关。
  • 证据等级为治疗性IV级,作者认为需前瞻性对照研究明确临床获益和潜在成本节约。

适用人群与场景

  • 急性颈段脊髓损伤患者,来自2005年1月至2017年5月的回顾性综述人群。
  • 倾向评分匹配基于年龄、损伤严重度评分、机械通气天数、住院时长和气管切开需求。

处置流程与药物剂量

  • 腹腔镜膈肌起搏植入(DPS)用于急性颈段脊髓损伤患者,以改善呼吸力学和促进脱机。

研究设计与关键结果

  • 研究类型为回顾性综述,2011年7月至2017年5月间37例DPS患者与34例未DPS者匹配。
  • DPS后自发潮气量较未DPS组显著增加(+88 mL vs -13 mL;95%CI 46-131 mL vs -78至51 mL;p=0.004)。
  • DPS后中位脱机时间显著缩短(10天 vs 29天;95%CI 6.5-13.6天 vs 23.1-35.3天;p<0.001)。
  • 出院前脱机率两组无差异。
  • 多因素线性回归显示DPS与脱机天数减少和自发潮气量增加显著相关。

证据类型、等级与局限

  • 证据类型为回顾性综述,证据等级为治疗性IV级。
  • 局限:作者指出需前瞻性对照研究明确DPS植入的临床获益和潜在成本节约。

对床旁实践的改变

  • 在急性颈段脊髓损伤机械通气患者中,DPS植入与自发潮气量增加和脱机时间缩短相关。
  • 作者认为需前瞻性对照研究明确DPS植入的临床获益和潜在成本节约。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Cervical spinal cord injury (CSCI) is devastating with ventilator-associated pneumonia being a main driver of morbidity and mortality. Laparoscopic diaphragm pacing implantation (DPS) has been used for earlier liberation from mechanical ventilation. We hypothesized that DPS would improve respiratory mechanics and facilitate liberation.

METHODS: We performed a retrospective review of acute CSCI patients between January 2005 and May 2017. Routine demographics were collected. Patients underwent propensity score matching based on age, Injury Severity Score, ventilator days, hospital length of stay, and need for tracheostomy. Patients with complete respiratory mechanics data were analyzed and compared. Those who did not have DPS (NO DPS) had spontaneous tidal volume (Vt) recorded at time of intensive care unit admission, at day 7, and at day 14, and patients who had DPS had spontaneous Vt recorded before and after DPS. Time to ventilator liberation and changes in size of spontaneous Vt for patients while on the ventilator were analyzed. Bivariate and multivariate logistic and linear regression statistics were performed using STATA v10.

RESULTS: Between July 2011 and May 2017, 37 patients that had DPS were matched to 34 who did not (NO DPS). Following DPS, there was a statistically significant increase in spontaneous Vt compared with NO DPS (+88 mL vs. -13 mL; 95% confidence interval, 46-131 mL vs. -78 to 51 mL, respectively; p = 0.004). Median time to liberation after DPS was significantly shorter (10 days vs. 29 days; 95% CI, 6.5-13.6 days vs. 23.1-35.3 days; p < 0.001). Liberation prior to hospital discharge was not different between the two groups. The DPS placement was found to be associated with a statistically significant decrease in days to liberation and an increase in spontaneous Vt in multivariate linear regression models.

CONCLUSION: The DPS implantation in acute CSCI patients produces significant improvements in spontaneous Vt and reduces time to liberation from mechanical ventilation. Prospective comparative studies are needed to define the clinical benefits and potential cost savings of DPS implantation.

LEVEL OF EVIDENCE: Therapeutic IV.

来源:J Trauma Acute Care Surg,查看原文。版权归原作者所有。

参考来源

  1. Kerwin AJ, Zuniga YD, Yorkgitis BK, et al. Diaphragm pacing improves respiratory mechanics in acute cervical spinal cord injury. J Trauma Acute Care Surg. 2020. PMID: 32467474. doi:10.1097/TA.0000000000002809

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。