简化脑电图抑制比在心脏骤停后目标温度管理期间的验证
该研究连续纳入23例心脏骤停后接受目标温度管理的成人患者,比较Medtronic Vista监测仪生成的抑制比(MSR)与全导联cEEG经Persyst Magic-Marker软件生成的抑制比(PSR),并由癫痫专科神经科医生盲法判读4通道aEEG模式和cEEG背景。结果显示MSR在cEEG连续背景时为0%、 discontinuous时为23%、 burst suppression时为64%(p=0.01);在aEEG连续模式时为0%、 burst suppression时为34%、 flat时为46%(p<0.001)。MSR与PSR高度相关(0.88,p<0.0001),偏倚小(0.3%),95%一致性界限为-2.9%至2.4%。作者结论认为MSR有效,可随aEEG模式和cEEG背景类别变化。
要点
- 在23例心脏骤停后目标温度管理成人中,Medtronic Vista监测仪的抑制比(MSR)与全导联cEEG经Persyst软件生成的抑制比(PSR)高度相关(0.88,p<0.0001),偏倚0.3%,95%一致性界限-2.9%至2.4%。
- MSR随cEEG背景变化:连续背景0%、 discontinuous 23%、 burst suppression 64%(p=0.01)。
- MSR随aEEG模式变化:连续模式0%、 burst suppression 34%、 flat 46%(p<0.001)。
- 作者结论认为Medtronic Vista监测仪生成的抑制比是有效的,可反映aEEG模式和cEEG背景类别的变化。
适用人群与场景
- 连续纳入的成人心脏骤停后接受目标温度管理的患者。
研究设计与关键结果
- 研究类型为验证性研究,连续纳入23例成人心脏骤停后目标温度管理患者,平均核心温度33.8°C(在抑制比与EEG背景分析时)。
- 比较Medtronic Vista监测仪生成的抑制比(MSR)与全导联cEEG经Persyst Magic-Marker软件生成的抑制比(PSR),并由癫痫专科认证神经科医生盲法判读4通道aEEG模式和cEEG背景。
- MSR在cEEG连续背景时为0%、 discontinuous时为23%、 burst suppression时为64%(p=0.01)。
- MSR在aEEG连续模式时为0%、 burst suppression时为34%、 flat时为46%(p<0.001)。
- MSR与PSR高度相关(0.88,p<0.0001),偏倚0.3%,95%一致性界限-2.9%至2.4%。
证据类型、等级与局限
- 证据类型:验证性研究(连续纳入成人患者)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者结论认为Medtronic Vista监测仪生成的抑制比与全导联Persyst软件抑制比高度相关,且MSR值有效,随aEEG模式和cEEG背景类别变化。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
AIM: The Suppression Ratio (SR) estimates the percent of the electroencephalography (EEG) epoch with very low voltage, and is associated with neurological outcome after cardiac arrest. We aimed to compare the SR generated by two monitoring devices and determine the association between SR and patterns on amplitude integrated EEG (aEEG) and full conventional EEG (cEEG).
METHODS: Consecutive adult patients treated with TTM after cardiac arrest were enrolled. We compared the SR from the Medtronic Vista monitor (MSR) to the SR generated from the full montage cEEG with Persyst Magic-Marker software (PSR). A blinded neurologist, board certified in epilepsy, scored the 4-channel aEEG pattern and the cEEG background using standardized terminology. Values for SR were compared to aEEG and cEEG categories using Kruskal-Wallis ANOVA, and to each other using Altman-Bland methodology.
RESULTS: 23 adults treated with TTM had a mean core temperature of 33.8 °C at the time of SR and EEG background analysis. The MSR was 0% during continuous cEEG background, 23% when cEEG was discontinuous, and 64% during cEEG burst suppression (p = 0.01). The MSR was 0% during aEEG continuous patterns, 34% during aEEG burst suppression, and 46% during flat aEEG (p < 0.001). The MSR and PSR were highly correlated (0.88, p < 0.0001), with minimal bias (0.3%) and excellent 95% limits of agreement (-2.9 to 2.4%).
CONCLUSION: The Suppression Ratio from the Medtronic Vista monitor is highly correlated with the full montage SR from Persyst software. The MSR values are valid, changing with different aEEG patterns and cEEG background categories.
参考来源
- Riker RR, Craig A, Eubank L, et al. Validation of the suppression ratio from a simplified EEG montage during targeted temperature management after cardiac arrest. Resuscitation. 2020. PMID: 32445782. doi:10.1016/j.resuscitation.2020.05.014
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。