文献速递儿科与产科急症

急诊科儿童静脉置管中的虚拟现实分散注意力:一项前瞻性随机对照研究

Virtual reality distraction during pediatric intravenous line placement in the emergency department: A prospective randomized comparison study.
PubMed 文献 · Am J Emerg Med · 2020-04-11
一句话结论在儿科急诊静脉置管中,虚拟现实分散注意力首次尝试成功率与标准分散注意力技术相似(81% vs 84.2%,p=.65),且79%的受试者可耐受虚拟现实头戴设备。

本研究为三级儿科急诊开展的前瞻性随机对照试验,纳入4-17岁需静脉置管、且儿童医疗辅导师不可用的患儿116例(虚拟现实组58例、标准治疗组58例),115例完成并分析。主要终点首次尝试静脉置管成功率两组相似(虚拟现实组81% vs 标准组84.2%,p=.65),置管次数及疼痛、焦虑评分变化亦相似。成功置管中位时间虚拟现实组更短(78 vs 104秒),但差异未达统计学显著(p=.21)。虚拟现实组79%受试者可耐受头戴设备,唯一显著预测耐受的因素是年龄较大(P=.02);作者认为虚拟现实分散注意力与标准分散注意力技术疗效相似,且似乎耐受良好。

要点

  • 首次尝试静脉置管成功率虚拟现实组81% vs 标准治疗组84.2%,两组相似(p=.65)
  • 成功置管中位时间虚拟现实组78秒 vs 标准组104秒,差异未达统计学显著(p=.21)
  • 两组置管次数及疼痛、焦虑评分变化相似
  • 虚拟现实组79%受试者可耐受头戴设备,唯一显著预测耐受的因素是年龄较大(P=.02)
  • 仅在儿童医疗辅导师不可用时纳入,虚拟现实用于4-17岁需静脉置管患儿

适用人群与场景

  • 三级儿科急诊中4-17岁需要静脉置管的患儿
  • 仅在儿童医疗辅导师不可用时纳入

研究设计与关键结果

  • 前瞻性随机对照试验,共纳入116例,虚拟现实组58例、标准治疗组58例,115例完成试验并分析
  • 主要终点首次尝试静脉置管成功率两组相似:虚拟现实组81% vs 标准治疗组84.2%(p=.65)
  • 置管次数以及疼痛、焦虑评分变化两组亦相似
  • 成功置管中位时间虚拟现实组78秒 vs 标准治疗组104秒,差异未达统计学显著(p=.21)
  • 虚拟现实组79%的受试者可耐受头戴设备,唯一显著预测头戴设备耐受的因素是年龄较大(P=.02)

证据类型、等级与局限

  • 研究类型:前瞻性随机对照试验
  • 局限:原文未报告局限性

对床旁实践的改变

  • 作者认为,在儿科急诊静脉置管中,虚拟现实分散注意力与标准分散注意力技术疗效相似,且似乎耐受良好
  • 纳入条件为儿童医疗辅导师不可用,适用人群为4-17岁需静脉置管的患儿

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the efficacy of virtual reality distraction (VR) during intravenous line (IV) placement in a pediatric emergency department to increase first-attempt IV success. Secondary endpoints included median time to successful IV placement, patient pain and anxiety scores, and an evaluation of characteristics of patients in whom VR is well tolerated.

STUDY DESIGN: This was a randomized controlled trial at a tertiary pediatric emergency department, enrolling patients aged 4-17 years who required IV placement. Patients were enrolled only when child life specialists were unavailable. The primary endpoint was first attempt IV success.

RESULTS: A total of 116 subjects were enrolled, 58 were randomly assigned to the VR group and 58 were assigned to the standard of care (SOC) group. 115 subjects completed the trial and were analyzed. First attempt IV success rates were similar between the groups (VR = 81%, standard = 84.2%, p = .65). Number of IV attempts and changes in pain and anxiety scores were also similar between the groups. The median time to successful IV placement was shorter in the VR group (78 vs 104 seconds) but this difference was not statistically significant (p = .21). Overall the VR headset was tolerated by 79% of subjects assigned to that group. The only significant predictor of headset tolerance was older age (P = .02).

CONCLUSIONS: VR distraction for IV placement in the Pediatric Emergency Department shows similar efficacy to standard distraction techniques and appears to be well tolerated.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Schlechter AK, Whitaker W, Iyer S, et al. Virtual reality distraction during pediatric intravenous line placement in the emergency department: A prospective randomized comparison study. Am J Emerg Med. 2020. PMID: 32307295. doi:10.1016/j.ajem.2020.04.009

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。