慢性阻塞性肺疾病急性加重序贯无创-有创机械通气最佳切换模式的临床研究
该回顾性研究纳入2014年7月至2019年3月在开封市中心医院急诊中心急诊抢救室接受机械通气并收入呼吸科的AECOPD患者,NIV组118例、IPPV组52例。两组总机械通气时间和住院死亡率无显著差异,但NIV组住院时间显著短于IPPV组。NIV组失败率14.4%。Logistic回归显示呼吸指数、pH值、白细胞计数和排痰引流是无创通气失败的独立危险因素,基于上述因素构建的风险预测模型对AECOPD患者无创通气失败具有较高预测价值(AUC 0.818±0.051)。
要点
- NIV组118例中17例失败转为IPPV,无创通气失败率为14.4%。
- NIV失败与成功患者间性别、氧合指数、呼吸指数、pH值、D-二聚体、降钙素原、白细胞计数、血乳酸、排痰引流和GCS评分差异有统计学意义。
- 呼吸指数(OR=3.879,95%CI 1.258-11.963,P=0.018)、pH值(OR=3.316,95%CI 1.270-8.660,P=0.014)、白细胞计数(OR=3.684,95%CI 1.172-11.581,P=0.026)和排痰引流(OR=0.125,95%CI 0.042-0.366,P=0.000)是无创通气失败的独立危险因素。
- 基于上述独立危险因素构建的NIV失败风险预测模型拟合优度良好(χ²=9.02,P=0.34),ROC曲线下面积AUC为0.818±0.051(95%CI 0.718-0.918,P=0.000)。
- NIV组与IPPV组总机械通气时间(65.6±11.11小时 vs 66.9±12.1小时)和住院死亡率(6.8% vs 9.6%)无显著差异(均P>0.05),但NIV组住院时间显著短于IPPV组(12.3±2.1天 vs 14.2±2.5天,P<0.05)。
适用人群与场景
- 2014年7月至2019年3月在开封市中心医院急诊中心急诊抢救室接受机械通气并收入呼吸科的AECOPD患者。
- 使用无创机械通气者纳入NIV组(118例),使用有创正压通气者纳入IPPV组(52例)。
诊断标准与关键阈值
- 基于呼吸指数、pH值、白细胞计数和排痰引流四项独立危险因素构建NIV失败风险预测模型,ROC曲线下面积AUC为0.818±0.051(95%CI 0.718-0.918,P=0.000)。
红旗征与不能漏的情况
- AECOPD患者存在NIV相对禁忌证但仍坚持使用NIV时,需进一步进行NIV失败风险分层。
- 呼吸指数、pH值、白细胞计数异常及排痰引流不佳者,选择NIV的风险显著增加,需更加关注病情变化并及时切换为IPPV,以避免病情恶化。
研究设计与关键结果
- NIV组101例连续完成NIV,17例NIV失败转为IPPV,NIV失败率为14.4%。
- NIV失败与NIV成功患者间性别、氧合指数、呼吸指数、pH值、D-二聚体、降钙素原、白细胞计数、血乳酸、排痰引流和GCS评分差异有统计学意义。
- Logistic回归显示呼吸指数(OR=3.879,95%CI 1.258-11.963,P=0.018)、pH值(OR=3.316,95%CI 1.270-8.660,P=0.014)、白细胞计数(OR=3.684,95%CI 1.172-11.581,P=0.026)和排痰引流(OR=0.125,95%CI 0.042-0.366,P=0.000)是NIV失败的独立危险因素。
- NIV失败风险预测模型拟合优度良好(χ²=9.02,P=0.34),对AECOPD患者NIV失败具有较高预测价值(AUC=0.818±0.051,95%CI 0.718-0.918,P=0.000)。
证据类型、等级与局限
- 证据类型:回顾性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,AECOPD患者存在NIV相对禁忌证但仍坚持使用NIV时,需进一步进行NIV失败风险分层。
- 作者认为,对于呼吸指数、pH值、白细胞计数异常及排痰引流不佳者,选择NIV的风险显著增加,需更加关注病情变化并及时切换为IPPV,以避免病情恶化。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
- 另有 1 条提炼内容因数值无法与原文逐一核对而未列出,请以原文为准。
英文原文(摘要)· 点击展开
OBJECTIVE: To explore the switch time of noninvasive-invasive mechanical ventilation sequential treatment for acute exacerbation of chronic obstructive pulmonary disease (AECOPD), and effectively reduce the rate of tracheal intubation.
METHODS: A retrospective study was performed on patients with AECOPD, who underwent mechanical ventilation in emergency resuscitation room and admitted to department of respiration of Kaifeng Central Hospital Emergency Center from July 2014 to March 2019. The patients who used noninvasive mechanical ventilation (NIV) were included in NIV group (118 cases), and those who used invasive positive pressure ventilation (IPPV) were included in IPPV group (52 cases). The usage of breathing machine time, hospital days and hospital mortality were compared between the two groups. Clinical indicators such as age, gender, body temperature, respiratory rate, body mass index (BMI), mean arterial pressure (MAP), oxygenation index (PaO2/FiO2), respiratory index (RI), pH value, D-dimer, hemoglobin (HB), albumin, blood lactate (Lac), brain natriuretic peptide (BNP), C-reactive protein (CRP), procalcitonin (PCT), serum creatinine (SCr), white blood cell count (WBC), Glasgow coma scale (GCS), sputum excretion drainage were collected. The factors influencing the failure of NIV were analyzed by Logistic stepwise regression analysis. The receiver operating characteristic (ROC) curve was used to test the value of the NIV failure risk prediction model.
RESULTS: There was no significant difference in total mechanical ventilation time and hospital mortality between NIV group and IPPV group (hours: 65.6±11.11 vs. 66.9±12.1, 6.8% vs. 9.6%, both P > 0.05), but the hospital time in group NIV was significantly shorter than that in IPPV group (days: 12.3±2.1 vs. 14.2±2.5, P < 0.05). In NIV group, 101 cases completed NIV continuously, 17 cases of NIV failure turned to IPPV, and the failure rate of NIV was 14.4%. There were statistically significant differences in gender, PaO2/FiO2, RI, pH value, D-dimer, PCT, WBC, Lac, sputum excretion drainage and GCS score between NIV failure patients and NIV success patients. Logistic regression analysis showed that RI, pH value, WBC and sputum excretion drainage were independent risk factors for NIV failure [RI: odds ratio (OR) = 3.879, 95% confidence interval (95%CI) was 1.258-11.963, P = 0.018; pH value: OR = 3.316, 95%CI was 1.270-8.660, P = 0.014; WBC: OR = 3.684, 95%CI was 1.172-11.581, P = 0.026; sputum excretion drainage: OR = 0.125, 95%CI was 0.042-0.366, P = 0.000]. The NIV failure risk prediction model based on the above independent risk factors had a good goodness of fit (χ 2 = 9.02, P = 0.34). ROC curve analysis showed that the NIV failure risk prediction model had a high predictive value for the patients with AECOPD [the area under ROC curve (AUC) was 0.818±0.051, 95%CI was 0.718-0.918, P = 0.000].
CONCLUSIONS: If patients with AECOPD have relative contraindications of NIV but still insist on using NIV, further risk stratification of NIV failure is needed. For those with RI, pH value, WBC abnormalities and sputum excretion drainage, the risk of choosing NIV is significantly increased. We need to pay more attention to the change of the condition and switch to IPPV in time to avoid exacerbation of the condition.
参考来源
- Zhai H, Luo S, Lin L, et al. [Clinical study on optimal switching mode in sequential noninvasive-invasive mechanical ventilation for acute exacerbation of chronic obstructive pulmonary disease]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2020. PMID: 32274999. doi:10.3760/cma.j.cn121430-20190923-00030
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。