较高水平呼气末正压对ICU非急性肺损伤/急性呼吸窘迫综合征患者急性呼吸窘迫综合征发生率的影响:一项Meta分析
该Meta分析纳入12项RCT(2篇中文、10篇英文),比较ICU中全身麻醉机械通气的非ALI/ARDS患者使用较高水平PEEP与较低水平PEEP的效果。结果显示两组住院死亡率和28天死亡率无显著差异;较高水平PEEP可提高氧分压、降低ARDS发生率和肺部感染发生率,但肺不张发生率两组无显著差异。作者结论认为,在这类患者中,使用较高水平PEEP(10-16 cmH2O)替代低水平PEEP(≤8 cmH2O)可显著提高氧分压并降低ARDS和肺部感染发生率。
要点
- 在ICU非ALI/ARDS全身麻醉机械通气患者中,较高水平PEEP较低水平PEEP降低ARDS发生率(OR=0.32,95%CI 0.13-0.82,P=0.02)。
- 较高水平PEEP较低水平PEEP降低肺部感染发生率(OR=0.52,95%CI 0.30-0.89,P=0.02)。
- 两组住院死亡率无显著差异(OR=1.06,95%CI 0.57-1.96,P=0.85),28天死亡率也无显著差异(OR=0.34,95%CI 0.09-1.32,P=0.12)。
- 两组肺不张发生率无显著差异(OR=0.69,95%CI 0.23-2.06,P=0.51)。
适用人群与场景
- ICU中全身麻醉机械通气的非急性肺损伤/急性呼吸窘迫综合征(non-ALI/ARDS)患者。
处置流程与药物剂量
- 作者结论:在ICU非ALI/ARDS全身麻醉机械通气患者中,使用较高水平PEEP(10-16 cmH2O)而非低水平PEEP(≤8 cmH2O)。
研究设计与关键结果
- 该Meta分析纳入12项RCT(2篇中文、10篇英文),比较较高水平PEEP与较低水平PEEP在ICU非ALI/ARDS全身麻醉机械通气患者中的效果。
- 住院死亡率:OR=1.06,95%CI 0.57-1.96,P=0.85;28天死亡率:OR=0.34,95%CI 0.09-1.32,P=0.12,两组均无统计学显著差异。
- 较高水平PEEP较低水平PEEP降低ARDS发生率(OR=0.32,95%CI 0.13-0.82,P=0.02)。
- 较高水平PEEP较低水平PEEP降低肺部感染发生率(OR=0.52,95%CI 0.30-0.89,P=0.02)。
- 两组肺不张发生率无显著差异(OR=0.69,95%CI 0.23-2.06,P=0.51)。
证据类型、等级与局限
- 证据类型:Meta分析,纳入12项RCT(2篇中文、10篇英文)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者结论认为,在ICU非ALI/ARDS全身麻醉机械通气患者中,使用较高水平PEEP(10-16 cmH2O)而非低水平PEEP(≤8 cmH2O)可显著提高氧分压并显著降低ARDS和肺部感染发生率。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
- 另有 2 条提炼内容因数值无法与原文逐一核对而未列出,请以原文为准。
英文原文(摘要)· 点击展开
OBJECTIVE: To systematically review the therapeutic effect of continuous high positive end-expiratory pressure (PEEP) ventilation in patients with non-acute lung injury/acute respiratory distress syndrome (non-ALI/ARDS) under general anesthesia mechanical ventilation in the intensive care unit (ICU).
METHODS: PubMed, JBI Evidence-based Nursing Center Library, Cochrane Library, Embase, Medline, Wanfang Date, CNKI and VIP Database were searched for randomized controlled trials (RCT) and clinical controlled trials (CCT) using different levels of PEEP for the treatment of patients (uncombined ALI/ARDS) in ICU. The search period was from January 1st, 1990 to November 30th, 2018. Compared with the control group, the experimental group was treated with relatively high levels of PEEP ventilation. Outcome indicators were hospital mortality or 28-day mortality, partial oxygen pressure, and incidence of ARDS, atelectasis, and lung infections, etc. The RevMan 5.3 software was used for Meta-analysis.
RESULTS: Twelve articles were included, all of which were RCT studies; with 2 Chinese articles and 10 English articles. Meta-analysis showd that there was no statistically significant difference in the effect of different levels of PEEP on the mortality of patients [hospital mortality: odds ratio (OR) = 1.06, 95% confidence interval (95%CI) was 0.57 to 1.96, P = 0.85; 28-day mortality: OR = 0.34, 95%CI was 0.09 to 1.32, P = 0.12]. Compared with low PEEP, persistently high PEEP could increase the patient's partial oxygen pressure [weighted mean difference (WMD) = 48.27, 95%CI was 22.56 to 73.97, P = 0.000 2], prevent the occurrence of ARDS (OR = 0.32, 95%CI was 0.13 to 0.82, P = 0.02), and decrease the incidence of lung infection (OR = 0.52, 95%CI was 0.30 to 0.89, P = 0.02), but there was no significant difference in the incidence of atelectasis between the two groups (OR = 0.69, 95%CI was 0.23 to 2.06, P = 0.51).
CONCLUSIONS: In the treatment of patients in ICU with non-ALI/ARDS under general anesthesia mechanical ventilation, using relatively high levels of PEEP (10-16 cmH2O, 1 cmH2O = 0.098 kPa) instead of low levels of PEEP (≤ 8 cmH2O) can significantly increase the partial oxygen pressure and significantly reduce the incidences of ARDS and lung infection.
参考来源
- Chen Y, Luo C, He B, et al. [Effect of positive end-expiratory pressure on the incidence of acute respiratory distress syndrome in non-acute lung injury/acute respiratory distress syndrome patients in ICU: a Meta-analysis]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2020. PMID: 32274998. doi:10.3760/cma.j.cn121430-20191010-00029
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。