文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

压力支持通气下自主呼吸试验失败患者摆动的发生情况:一项观察性研究

Occurrence of pendelluft under pressure support ventilation in patients who failed a spontaneous breathing trial: an observational study.
PubMed 文献 · Ann Intensive Care · 2020-04-07
一句话结论在自主呼吸试验失败的20例患者中,40%经电阻抗断层成像检测到高摆动,摆动随压力支持降低而增加并与呼气末二氧化碳升高相关。

本研究为一项在三级教学医院综合重症监护病房开展的观察性研究,对20例自主呼吸试验失败的患者,在压力支持通气从临床水平逐步降至2 cmH2O的过程中记录电阻抗断层成像信号,将四个腹侧至背侧感兴趣区中与整体电阻抗断层成像信号方向相反、幅度大于6 mL的局部气体运动定义为高摆动。结果显示20例中8例(40%)被归类为高摆动,高摆动组与低摆动组基线临床特征无差异;压力支持降低时高摆动组摆动和呼气末二氧化碳增加更明显(p < .001和.011)。摆动气体几乎完全从腹侧向背侧移动,反向运动极少(16.3 [10:32.8] vs. 0 [0:1.8] mL,p = .001)。部分患者中摆动体积增加与呼吸频率、p0.1和呼气末二氧化碳等呼吸窘迫标志物正相关。结论认为电阻抗断层成像可测得隐匿性摆动,其在自主呼吸试验失败患者中常见,出现时随通气支持降低而增加并与呼气末二氧化碳升高相关,提示消除二氧化碳能力下降。

要点

  • 自主呼吸试验失败的20例患者中8例(40%)经电阻抗断层成像检测为高摆动。
  • 压力支持从临床水平降至2 cmH2O时,高摆动组摆动和呼气末二氧化碳增加较低摆动组更明显(p < .001和.011)。
  • 摆动气体主要从腹侧向背侧移动,腹侧至背侧方向为16.3 [10:32.8] mL,反向为0 [0:1.8] mL(p = .001)。
  • 部分患者中摆动体积增加与呼吸频率、p0.1和呼气末二氧化碳升高正相关。
  • 高摆动组与低摆动组基线临床特征无差异,提示常规指标可能无法识别高摆动。

适用人群与场景

  • 在三级教学医院综合重症监护病房中,自主呼吸试验失败并接受压力支持通气的20例患者。
  • 压力支持从临床水平(基线)逐步降至2 cmH2O,模拟自主呼吸试验过程。

诊断标准与关键阈值

  • 高摆动的电阻抗断层成像诊断标准:四个腹侧至背侧感兴趣区中,出现与整体电阻抗断层成像信号方向相反、幅度大于6 mL的局部气体运动。

研究设计与关键结果

  • 研究类型为观察性研究,样本量20例,在综合重症监护病房进行,未报告中心数。
  • 20例中8例(40%)被归类为高摆动;高摆动组与低摆动组基线临床特征无差异。
  • 压力支持降低时,高摆动组摆动和呼气末二氧化碳增加较低摆动组更明显(p < .001和.011)。
  • 摆动气体几乎完全从腹侧向背侧移动,腹侧至背侧方向为16.3 [10:32.8] mL,反向为0 [0:1.8] mL(p = .001)。
  • 在部分患者中,摆动体积增加与呼吸频率、p0.1和呼气末二氧化碳等呼吸窘迫标志物正相关。

证据类型、等级与局限

  • 证据类型:观察性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为电阻抗断层成像可测得隐匿性摆动,其在自主呼吸试验失败患者中常见,出现时随通气支持降低而增加并与呼气末二氧化碳升高相关,提示消除二氧化碳能力下降。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Pendelluft, the movement of gas within different lung regions, is present in animal models of assisted mechanical ventilation and associated with lung overstretching. Due to rebreathing of CO2 as compared to fresh gas, pendelluft might reduce ventilatory efficiency possibly exacerbating patient's respiratory workload during weaning. Our aim was to measure pendelluft by electrical impedance tomography (EIT) in patients who failed a spontaneous breathing trial (SBT).

METHODS: This is an observational study conducted in a general intensive care unit of a tertiary-level teaching hospital. EIT signal was recorded in 20 patients while pressure support (PS) ventilation was progressively reduced from clinical level (baseline) to 2 cmH2O, as in an SBT; four ventral-to-dorsal lung regions of interest were identified for pendelluft measurement. A regional gas movement (> 6 mL) occurring in a direction opposite to the global EIT signal was considered diagnostic for high pendelluft.

RESULTS: Eight patients out of 20 (40%) were classified as high-pendelluft; baseline clinical characteristics did not differ between high- and low-pendelluft patients. At PS reduction, pendelluft and EtCO2 increased more in the high-pendelluft group (p < .001 and .011, respectively). The volume of gas subject to pendelluft moved almost completely from the ventral towards the dorsal lung regions, while the opposite movement was minimal (16.3 [10:32.8] vs. 0 [0:1.8] mL, p = .001). In a subgroup of patients, increased pendelluft volumes positively correlated with markers of respiratory distress such as increased respiratory rate, p0.1, and EtCO2.

CONCLUSIONS: Occult pendelluft can be measured by EIT, and is frequently present in patients failing an SBT. When present, pendelluft increases with the reduction of ventilator support and is associated with increased EtCO2, suggesting a reduction of the ability to eliminate CO2.

来源:Ann Intensive Care,查看原文。版权归原作者所有。