文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

ARDS患者增加PEEP后分流、通气/灌注失匹配与肺复张的变化:一项前瞻性单臂干预研究

Changes in shunt, ventilation/perfusion mismatch, and lung aeration with PEEP in patients with ARDS: a prospective single-arm interventional study.
PubMed 文献 · Crit Care · 2020-03-23
一句话结论ARDS患者增加PEEP后肺复张改善并不总伴随分流和V/Q失匹配改善,部分患者分流与高V/Q失匹配反而恶化。

该前瞻性单臂干预研究纳入12例ARDS患者,在肺复张手法后将PEEP设为5 cmH2O,再设为15或20 cmH2O,用CT测量肺复张,用模型法计算肺分流及低、高V/Q失匹配。增加PEEP后分流和非充气组织百分比降低、正常充气组织百分比增加(p<0.05),分流变化与正常充气组织变化显著相关(r=-0.665,p=0.018)。7例呈有益反应(分流下降且高V/Q未增加),4例呈有害反应(分流和高V/Q均增加),1例分流下降但高V/Q增加。非充气组织在所有患者中均随PEEP增加而减少,过度充气组织仅在分流和V/Q失匹配有害反应的患者中增加。结论提示PEEP增加后的肺复张改善并不总是与分流和V/Q失匹配改善一致。

要点

  • 12例ARDS患者增加PEEP后,分流和非充气组织百分比降低、正常充气组织百分比增加(p<0.05)。
  • 分流变化与正常充气组织变化显著相关(r=-0.665,p=0.018)。
  • 7例呈有益反应:分流下降且高V/Q未增加;4例呈有害反应:分流和高V/Q均增加;1例分流下降但高V/Q增加。
  • 非充气组织在所有患者中均随PEEP增加而减少,过度充气组织仅在分流和V/Q失匹配有害反应的患者中增加。
  • 增加PEEP后肺复张改善并不总是与分流和V/Q失匹配改善一致,通气与灌注在依赖区与非依赖区之间匹配不良可能解释这一现象。

适用人群与场景

  • 12例ARDS患者,纳入本前瞻性单臂干预研究。

处置流程与药物剂量

  • 对ARDS患者行肺复张手法后,先将PEEP设为5 cmH2O,再设为15或20 cmH2O。

研究设计与关键结果

  • 研究类型为前瞻性单臂干预研究,样本量12例ARDS患者,干预为肺复张手法后PEEP设为5 cmH2O再设为15或20 cmH2O,主要观察增加PEEP后分流、低和高V/Q失匹配与CT测量的肺充气之间的关联。
  • 增加PEEP后肺分流值和非充气组织百分比降低,正常充气组织百分比增加(p<0.05)。
  • 分流变化与正常充气组织变化显著相关(r=-0.665,p=0.018)。
  • 增加PEEP后分流和V/Q失匹配出现三种不同反应:7例有益反应(分流下降且高V/Q未增加);4例有害反应(分流和高V/Q均增加);1例有害反应(分流下降但高V/Q失匹配增加)。
  • 非充气组织在所有患者中均随PEEP增加而减少,过度充气组织仅在分流和V/Q失匹配有害反应的患者中增加。

证据类型、等级与局限

  • 证据类型:前瞻性单臂干预研究(初步研究)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,增加PEEP后肺复张改善并不总是与分流和V/Q失匹配改善一致;通气与灌注在肺依赖区与非依赖区之间匹配不良,可能解释部分患者增加PEEP后分流和V/Q失匹配反而恶化的现象。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Several studies have found only a weak to moderate correlation between oxygenation and lung aeration in response to changes in PEEP. This study aimed to investigate the association between changes in shunt, low and high ventilation/perfusion (V/Q) mismatch, and computed tomography-measured lung aeration following an increase in PEEP in patients with ARDS.

METHODS: In this preliminary study, 12 ARDS patients were subjected to recruitment maneuvers followed by setting PEEP at 5 and then either 15 or 20 cmH2O. Lung aeration was measured by computed tomography. Values of pulmonary shunt and low and high V/Q mismatch were calculated by a model-based method from measurements of oxygenation, ventilation, and metabolism taken at different inspired oxygen levels and an arterial blood gas sample.

RESULTS: Increasing PEEP resulted in reduced values of pulmonary shunt and the percentage of non-aerated tissue, and an increased percentage of normally aerated tissue (p < 0.05). Changes in shunt and normally aerated tissue were significantly correlated (r = - 0.665, p = 0.018). Three distinct responses to increase in PEEP were observed in values of shunt and V/Q mismatch: a beneficial response in seven patients, where shunt decreased without increasing high V/Q; a detrimental response in four patients where both shunt and high V/Q increased; and a detrimental response in a patient with reduced shunt but increased high V/Q mismatch. Non-aerated tissue decreased with increased PEEP in all patients, and hyperinflated tissue increased only in patients with a detrimental response in shunt and V/Q mismatch.

CONCLUSIONS: The results show that improved lung aeration following an increase in PEEP is not always consistent with reduced shunt and V/Q mismatch. Poorly matched redistribution of ventilation and perfusion, between dependent and non-dependent regions of the lung, may explain why patients showed detrimental changes in shunt and V/Q mismatch on increase in PEEP, despite improved aeration.

TRIAL REGISTRATION: ClinicalTrails.gov, NCT04067154. Retrospectively registered on August 26, 2019.

来源:Crit Care,查看原文。版权归原作者所有。