基于血流动力学与液体平衡参数的撤机失败预测模型的初步建立
该回顾性分析纳入2017年1月1日至2018年12月31日天津市第三中心医院ICU接受有创机械通气>24小时并完成自主呼吸试验的患者159例,按撤机成功(138例)与失败(21例)分组。两组入ICU后24小时内PiCCO血流动力学参数、BNP、尿量及液体平衡均无统计学差异;撤机前24小时内BNP、CVP、dPmx、尿量、液体平衡差异有统计学意义。将BNP、CVP、CI、dPmx、尿量、液体平衡量纳入多因素Logistic回归建立撤机失败预测模型,准确率92.9%、敏感度100%、特异度76.8%;经年龄与去甲肾上腺素使用调整后准确率94.2%、敏感度100%、特异度81.2%。作者认为该模型准确度较高,可指导临床撤机。
要点
- 撤机前24小时内BNP、CVP、dPmx、尿量、液体平衡在撤机成功组与失败组间差异有统计学意义(BNP χ2=9.262,P=0.026;CVP χ2=7.948,P=0.047;dPmx χ2=10.486,P=0.015;尿量 χ2=8.921,P=0.030;液体平衡 χ2=9.172,P=0.027)。
- 入ICU后24小时内的PiCCO血流动力学参数、BNP、尿量及液体平衡在两组间均无统计学差异。
- 最终纳入多因素Logistic回归的变量为BNP、CVP、CI、dPmx、尿量、液体平衡量,模型预测撤机失败准确率92.9%、敏感度100%、特异度76.8%。
- 经年龄和去甲肾上腺素使用调整后,模型预测撤机失败准确率94.2%、敏感度100%、特异度81.2%。
- CI在两组间比较χ2=7.789、P=0.051,为完善预测模型、提高模型准确度而纳入多因素Logistic回归模型。
适用人群与场景
- 2017年1月1日至2018年12月31日天津市第三中心医院ICU接受有创机械通气超过24小时并完成自主呼吸试验的患者。
研究设计与关键结果
- 研究类型为回顾性分析,共纳入159例患者,其中撤机成功组138例、撤机失败组21例。
- 两组入ICU后24小时内PiCCO监测的全部血流动力学参数、BNP、尿量、液体平衡均无统计学差异。
- 撤机前24小时内BNP(χ2=9.262,P=0.026)、CVP(χ2=7.948,P=0.047)、dPmx(χ2=10.486,P=0.015)、尿量(χ2=8.921,P=0.030)、液体平衡(χ2=9.172,P=0.027)在两组间差异有统计学意义。
- CI在两组间比较χ2=7.789、P=0.051,为完善预测模型、提高模型准确度而纳入多因素Logistic回归模型。
- 最终纳入多因素Logistic回归模型的变量为BNP、CVP、CI、dPmx、尿量、液体平衡量,模型预测撤机失败的准确率92.9%、敏感度100%、特异度76.8%。
- 经年龄和去甲肾上腺素使用调整后,模型预测撤机失败的准确率94.2%、敏感度100%、特异度81.2%。
证据类型、等级与局限
- 证据类型:回顾性分析。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,基于PiCCO监测的血流动力学参数及液体平衡相关变量建立的撤机失败预测模型准确度较高,可指导临床撤机。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To establish a model that can predict weaning failure from ventilation through hemodynamic and fluid balance parameters.
METHODS: A retrospective analysis was conducted. The patients who underwent invasive mechanical ventilation for more than 24 hours and having spontaneous breathing test admitted to intensive care unit (ICU) of Tianjin Third Central Hospital from January 1st, 2017 to December 31st, 2018 were enrolled. The information was collected, which included the baseline data, hemodynamic parameters by pulse indicator continuous cardiac output (PiCCO) monitoring, B-type natriuretic peptide (BNP), urinary output, fluid balance in first 24 hours when patients admitted to ICU, and hemodynamic parameters by PiCCO monitoring, BNP, urinary output, fluid balance, diuretic usage, noradrenalin usage within 24 hours before weaning as well as usage of continuous renal replacement therapy (CRRT) during mechanical ventilation. According to weaning success or failure, the patients were divided into weaning success group and weaning failure group, and the statistical differences between the two groups were calculated. Variables with statistical significance within 24 hours before weaning were included in the multivariate Logistic regression analysis to establish weaning failure prediction model and find out the possible risk factors of weaning failure.
RESULTS: A total of 159 patients were included in this study, which included 138 patients in the weaning success group and 21 patients in the weaning failure group. There were no statistical differences in all hemodynamic parameters by PiCCO monitoring, BNP, urinary output, fluid balance within 24 hours into ICU between two groups. There were statistical differences in BNP (χ2 = 9.262, P = 0.026), central venous pressure (CVP; χ2 = 7.948, P = 0.047), maximum rate of the increase in pressure (dPmx; χ2 = 10.486, P = 0.015), urinary output (χ2 = 8.921, P = 0.030), fluid balance (χ2 = 9.172, P = 0.027) within 24 hours before weaning between two groups. In addition, variable about cardiac index (CI; χ2 = 7.789, P = 0.051) was included into multivariate Logistic regression model to improve the prediction model and enhance the accuracy of model. Finally, variables included in the multivariate Logistic regression model were BNP, CVP, CI, dPmx, urinary output, fluid balance volume, and the accuracy of the weaning failure prediction model was 92.9%, the sensitivity was 100%, and the specificity was 76.8%. When the model was adjusted by variables of age and noradrenalin usage, the accuracy of model to predict failure of weaning was 94.2%, the sensitivity was 100%, the specificity was 81.2%.
CONCLUSIONS: Weaning failure prediction model based on hemodynamic parameters by PiCCO monitoring and variables about liquid balance has high accuracy and can guide clinical weaning.
参考来源
- Liu L, Yin C, Zhi Y, et al. [Preliminary establishment of weaning prediction model]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2020. PMID: 32275001. doi:10.3760/cma.j.cn121430-20191015-00032
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。