文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

重症成人患者呼吸机相关性肺炎的诊断:系统评价与Meta分析

Diagnosis of ventilator-associated pneumonia in critically ill adult patients-a systematic review and meta-analysis.
PubMed 文献 · Intensive Care Med · 2020-04-18
一句话结论经典临床指标诊断VAP准确性差,依赖单一指标可能导致误诊和不必要的抗菌药物使用。

该系统评价与Meta分析纳入25项研究共1639例患者,以组织病理学为标准,评估体格检查、胸片、气管内吸引物、支气管镜采样培养(PSB和BAL)及CPIS>6诊断VAP的准确性。结果显示,发热、脓性分泌物、胸片浸润影、ETA、PSB、BAL及CPIS>6的敏感性和特异性均不理想,胸片浸润影敏感性88.9%但特异性仅26.1%。经典临床指标诊断VAP准确性差,单独依赖这些指标可能导致误诊和不必要的抗菌药物使用。

要点

  • 胸片任一浸润影诊断VAP敏感性88.9%(95%CI 73.9-95.8),特异性仅26.1%(95%CI 15.1-41.4)。
  • BAL诊断VAP敏感性71.1%(95%CI 49.9-85.9),特异性79.6%(95%CI 66.2-85.9);PSB敏感性61.4%(95%CI 43.7-76.5),特异性76.5%(95%CI 64.2-85.6)。
  • ETA诊断VAP敏感性75.7%(95%CI 51.5-90.1),特异性67.9%(95%CI 40.5-86.8)。
  • CPIS>6诊断VAP敏感性73.8%(95%CI 50.6-88.5),特异性66.4%(95%CI 43.9-83.3)。
  • 发热诊断VAP敏感性66.4%(95%CI 40.7-85.0),特异性53.9%(95%CI 34.5-72.2);脓性分泌物敏感性77.0%(95%CI 64.7-85.9),特异性39.0%(95%CI 25.8-54.0)。

适用人群与场景

  • 重症成人患者,疑似呼吸机相关性肺炎(VAP),研究场景为ICU。

诊断标准与关键阈值

  • 以组织病理学分析为参考标准诊断VAP。
  • 评估的指标包括:体格检查(发热、脓性分泌物)、胸片(任一浸润影)、气管内吸引物(ETA)、支气管镜采样培养(保护性标本刷[PSB]和支气管肺泡灌洗[BAL])、CPIS>6。

研究设计与关键结果

  • 系统评价与Meta分析,纳入25项研究,共1639例患者。
  • 发热诊断VAP的汇总敏感性66.4%(95%CI 40.7-85.0),特异性53.9%(95%CI 34.5-72.2)。
  • 脓性分泌物诊断VAP的汇总敏感性77.0%(95%CI 64.7-85.9),特异性39.0%(95%CI 25.8-54.0)。
  • 胸片任一浸润影诊断VAP的汇总敏感性88.9%(95%CI 73.9-95.8),特异性26.1%(95%CI 15.1-41.4)。
  • ETA诊断VAP的汇总敏感性75.7%(95%CI 51.5-90.1),特异性67.9%(95%CI 40.5-86.8)。
  • PSB诊断VAP的汇总敏感性61.4%(95%CI 43.7-76.5),特异性76.5%(95%CI 64.2-85.6)。
  • BAL诊断VAP的汇总敏感性71.1%(95%CI 49.9-85.9),特异性79.6%(95%CI 66.2-85.9)。
  • CPIS>6诊断VAP的汇总敏感性73.8%(95%CI 50.6-88.5),特异性66.4%(95%CI 43.9-83.3)。

证据类型、等级与局限

  • 证据类型:系统评价与Meta分析,纳入25项研究共1639例患者,检索六个数据库至2019年9月,纳入英文研究,两名评价员独立提取数据并评估研究质量。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 经典临床指标(发热、脓性分泌物、胸片浸润影、CPIS>6)诊断VAP准确性差。
  • 单独依赖这些指标可能导致误诊和潜在的不必要抗菌药物使用。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

The accuracy of the signs and tests that clinicians use to diagnose ventilator-associated pneumonia (VAP) and initiate antibiotic treatment has not been well characterized. We sought to characterize and compare the accuracy of physical examination, chest radiography, endotracheal aspirate (ETA), bronchoscopic sampling cultures (protected specimen brush [PSB] and bronchoalveolar lavage [BAL]), and CPIS > 6 to diagnose VAP. We searched six databases from inception through September 2019 and selected English-language studies investigating accuracy of any of the above tests for VAP diagnosis. Reference standard was histopathological analysis. Two reviewers independently extracted data and assessed study quality. We included 25 studies (1639 patients). The pooled sensitivity and specificity of physical examination findings for VAP were poor: fever (66.4% [95% confidence interval [CI]: 40.7-85.0], 53.9% [95% CI 34.5-72.2]) and purulent secretions (77.0% [95% CI 64.7-85.9], 39.0% [95% CI 25.8-54.0]). Any infiltrate on chest radiography had a sensitivity of 88.9% (95% CI 73.9-95.8) and specificity of 26.1% (95% CI 15.1-41.4). ETA had a sensitivity of 75.7% (95% CI 51.5-90.1) and specificity of 67.9% (95% CI 40.5-86.8). Among bronchoscopic sampling methods, PSB had a sensitivity of 61.4% [95% CI 43.7-76.5] and specificity of 76.5% [95% CI 64.2-85.6]; while BAL had a sensitivity of 71.1% [95% CI 49.9-85.9] and specificity of 79.6% [95% CI 66.2-85.9]. CPIS > 6 had a sensitivity of 73.8% (95% CI 50.6-88.5) and specificity of 66.4% (95% CI 43.9-83.3). Classic clinical indicators had poor accuracy for diagnosis of VAP. Reliance upon these indicators in isolation may result in misdiagnosis and potentially unnecessary antimicrobial use.

来源:Intensive Care Med,查看原文。版权归原作者所有。

参考来源

  1. Fernando SM, Tran A, Cheng W, et al. Diagnosis of ventilator-associated pneumonia in critically ill adult patients-a systematic review and meta-analysis. Intensive Care Med. 2020. PMID: 32306086. doi:10.1007/s00134-020-06036-z

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。