Sepsis-3标准对脓毒症患者的诊断价值:多中心前瞻性观察性临床研究
该多中心前瞻性观察性研究纳入江苏省6家医院ICU 2017年9月至2018年8月收治的感染或疑似感染患者527例,按是否符合Sepsis-1和Sepsis-3标准分为A、B、C、D四组。A组(符合两种标准)324例、B组(仅符合Sepsis-1)113例、C组(仅符合Sepsis-3)22例、D组(均不符合)68例,28天死亡率分别为38.9%、17.7%、31.8%、11.8%,四组间差异有统计学意义(P<0.05)。SOFA评分预测28天死亡的AUC为0.71(95%CI 0.66-0.76),优于qSOFA的0.59(0.55-0.64)和SIRS的0.57(0.51-0.62)(均P<0.01)。作者结论认为Sepsis-3标准在诊断和预测28天死亡方面优于Sepsis-1标准,qSOFA可作为ICU床旁快速筛查高危脓毒症患者的早期工具。
要点
- 527例ICU感染或疑似感染患者中,符合Sepsis-1和Sepsis-3的A组28天死亡率38.9%,仅符合Sepsis-1的B组17.7%,仅符合Sepsis-3的C组31.8%,均不符合的D组11.8%(P<0.05)。
- SOFA评分预测28天死亡的AUC为0.71(95%CI 0.66-0.76),优于qSOFA的0.59(0.55-0.64)和SIRS的0.57(0.51-0.62)(均P<0.01)。
- SOFA评分预测28天死亡的最佳截断值为7分,敏感度69.4%、特异度61.8%;qSOFA最佳截断值2分,敏感度60.1%、特异度76.2%;SIRS最佳截断值2分,敏感度53.6%、特异度51.1%。
- 作者结论认为Sepsis-3标准在诊断和预测28天死亡方面优于Sepsis-1标准。
- 作者认为qSOFA可作为ICU床旁快速筛查高危脓毒症患者的早期工具。
适用人群与场景
- 江苏省6家医院ICU 2017年9月至2018年8月收治的感染或疑似感染患者,共527例。
- 按是否符合Sepsis-1和Sepsis-3标准分为四组:A组两者均符合324例,B组仅符合Sepsis-1 113例,C组仅符合Sepsis-3 22例,D组两者均不符合68例。
诊断标准与关键阈值
- Sepsis-1标准与Sepsis-3标准,按患者符合情况分为A、B、C、D四组。
- SOFA评分预测脓毒症患者28天死亡的最佳截断值为7分(敏感度69.4%、特异度61.8%)。
- qSOFA评分预测28天死亡的最佳截断值为2分(敏感度60.1%、特异度76.2%)。
- SIRS评分预测28天死亡的最佳截断值为2分(敏感度53.6%、特异度51.1%)。
研究设计与关键结果
- 多中心前瞻性观察性临床研究,纳入6家医院ICU感染或疑似感染患者527例,比较Sepsis-1与Sepsis-3标准的诊断价值。
- A、B、C、D四组28天死亡率分别为38.9%、17.7%、31.8%、11.8%,四组间差异有统计学意义(P<0.05)。
- A、B、C、D四组SIRS评分分别为3(1)、2(1)、1(0)、1(0),APACHE II评分分别为17(10)、11(10)、15(8)、12(8),qSOFA评分分别为2(1)、1(1)、1(1)、1(2),SOFA评分分别为8(6)、1(0)、7(4)、1(0),四组间差异均有统计学意义(均P<0.05)。
- SOFA评分预测28天死亡的AUC为0.71(95%CI 0.66-0.76),优于qSOFA的0.59(0.55-0.64)和SIRS的0.57(0.51-0.62)(均P<0.01)。
- SOFA、qSOFA、SIRS评分预测28天死亡的最佳截断值分别为7、2、2,敏感度分别为69.4%、60.1%、53.6%,特异度分别为61.8%、76.2%、51.1%。
证据类型、等级与局限
- 证据类型:多中心前瞻性观察性临床研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者结论认为Sepsis-3标准在脓毒症患者诊断和28天死亡预测方面优于Sepsis-1标准。
- 作者认为qSOFA可作为ICU床旁快速筛查高危脓毒症患者的早期工具。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To explore the value of Sepsis-3 standard in diagnosis of patients with sepsis.
METHODS: Patients who were infected or suspected of infection in intensive care unit (ICU) of six hospitals in Jiangsu Province from September 2017 to August 2018 were enrolled. They were divided into four groups: group A was in accordance with Sepsis-1 and Sepsis-3, group B only met the Sepsis-1 standard, group C only met the Sepsis-3 standard, and both Sepsis-1 and Sepsis-3 standard did not match in group D. The age, gender, underlying disease, diagnosis and source of infection, vital signs within 24 hours of ICU, systemic inflammatory response syndrome (SIRS) score, sequential organ failure assessment (SOFA) score, acute physiology and chronic health evaluation II (APACHE II) score, quick sequential organ failure assessment (qSOFA) score, the length of ICU stay, total hospitalization time, 28-day mortality rate, etc. were recorded. The above collected data were compared and analyzed in groups, and the receiver operating characteristic (ROC) curves of each scoring standard were drawn and calculated. The area under the ROC curve (AUC), and the Youden index of each score was calculated to predict the optimal cut-off value of 28-day mortality in patients with sepsis and its corresponding sensitivity and specificity.
RESULTS: A total of 527 patients with infection or suspected infection were enrolled in the study, including 324 patients in group A, 113 patients in group B, 22 patients in group C, 68 patients in group D, and 28-day mortality were 38.9%, 17.7%, 31.8%, and 11.8%, respectively, and there was statistically significant difference among four groups (P < 0.05). The SIRS scores of the A, B, C, D groups were 3 (1), 2 (1), 1 (0), 1 (0), APACHE II scores were 17 (10), 11 (10), 15 (8), 12 (8), qSOFA score were 2 (1), 1 (1), 1 (1), 1 (2), SOFA scores were 8 (6), 1 (0), 7 (4), 1 (0), respectively, there were statistically significant differences among four group (all P < 0.05). Values of SOFA, qSOFA and SIRS scores were evaluated by ROC to predict the value of 28-day mortality. The results showed that AUC and 95% confidence interval of SOFA score was superior to qSOFA score and SIRS score [0.71 (0.66-0.76) vs. 0.59 (0.55-0.64), 0.57 (0.51-0.62), both P < 0.01]. According to the Youden index, the best cut-off values for the 28-day mortality of SOFA, qSOFA and SIRS scores for sepsis were 7, 2 and 2, respectively, and the sensitivity was 69.4%, 60.1%, 53.6%, the specificity was 61.8%, 76.2%, 51.1%, respectively.
CONCLUSIONS: The Sepsis-3 standard is superior to the Sepsis-1 standard in the diagnosis and prediction of 28-day mortality in patients with sepsis. qSOFA can be used as an early tool for rapid screening of patients with high-risk sepsis in the ICU bedside.
参考来源
- Shao J, Yuan Z, Chen Q, et al. [Diagnostic value of the Sepsis-3 standard for patients with sepsis: a multi-center prospective, observational clinical study]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2020. PMID: 32274993. doi:10.3760/cma.j.cn121430-20191224-00024
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。