文献速递重症综合管理与镇静镇痛

单中心前瞻性观察研究:危重症不同阶段静息能量消耗的间接测热法与预测公式比较

A Single-Center Prospective Observational Study Comparing Resting Energy Expenditure in Different Phases of Critical Illness: Indirect Calorimetry Versus Predictive Equations.
PubMed 文献 · Crit Care Med · 2020-01-01
一句话结论在机械通气危重患者中,各阶段预测公式与间接测热法一致性均不佳,Swinamer(1990)公式在急性期、晚期和慢性期相对一致性较好,可在无间接测热法时用于预测静息能量消耗。

该单中心前瞻性观察研究在马来亚大学医学中心综合ICU纳入机械通气危重患者,用15种常用预测公式估算静息能量消耗,并与间接测热法实测值在不同疾病阶段(急性期≤5天、晚期6-10天、慢性期≥11天)进行比较。间接测热法分别在急性期305例、晚期180例、慢性期91例患者中测量。三个阶段的平均静息能量消耗存在显著差异(F=3.447;p=0.034),晚期(1878±517 kcal)显著高于急性期(1765±456 kcal)(p=0.037)。急性期一致性和准确性最佳为Swinamer(1990),晚期为Brandi(1999)和Swinamer(1990),慢性期为Swinamer(1990);没有任何预测公式估算值与间接测热法实测值达到很好的一致性。

要点

  • 在机械通气危重患者中,晚期静息能量消耗(1878±517 kcal)显著高于急性期(1765±456 kcal)(p=0.037)。
  • 15种常用预测公式在各阶段与间接测热法的一致性均未达到很好水平,预测公式倾向于高估或低估静息能量消耗。
  • 急性期一致性和准确性最佳的预测公式为Swinamer(1990),晚期为Brandi(1999)和Swinamer(1990),慢性期为Swinamer(1990)。
  • 含「动态」变量和呼吸数据的预测公式,与间接测热法实测值的一致性优于为健康成人开发的公式或基于「静态」变量的公式。
  • Swinamer(1990)在急性期、晚期和慢性期三个阶段的相对一致性较好,可在无间接测热法时用于预测静息能量消耗。

适用人群与场景

  • 纳入人群:机械通气危重患者。
  • 研究场景:马来亚大学医学中心综合ICU。
  • 疾病阶段:急性期(≤5天)、晚期(6-10天)、慢性期(≥11天)。

诊断标准与关键阈值

  • 急性期:≤5天;晚期:6-10天;慢性期:≥11天。
  • 预测公式准确性判定:预测公式估算的静息能量消耗与间接测热法实测值相差在±10%以内。

研究设计与关键结果

  • 研究类型:单中心前瞻性观察研究;样本量:间接测热法在急性期、晚期和慢性期分别测量305例、180例和91例ICU患者。
  • 三个阶段的平均静息能量消耗存在显著差异(F=3.447;p=0.034);晚期(1878±517 kcal)显著高于急性期(1765±456 kcal)(p=0.037)。
  • 急性期一致性和准确性最佳的预测公式为Swinamer(1990),晚期为Brandi(1999)和Swinamer(1990),慢性期为Swinamer(1990)。
  • 没有任何预测公式估算的静息能量消耗与间接测热法实测值达到很好的一致性。
  • 含「动态」变量和呼吸数据的预测公式,与间接测热法实测值的一致性优于为健康成人开发的公式或基于「静态」变量的公式。

证据类型、等级与局限

  • 证据类型:单中心前瞻性观察研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 预测公式在不同疾病阶段倾向于高估或低估静息能量消耗,使用时应意识到这一偏差。
  • 当无条件进行间接测热法时,Swinamer(1990)公式在急性期、晚期和慢性期相对一致性较好,可用于预测静息能量消耗。
  • 含「动态」变量和呼吸数据的预测公式可能比基于「静态」变量的公式或为健康成人开发的公式更接近间接测热法实测值。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: Several predictive equations have been developed for estimation of resting energy expenditure, but no study has been done to compare predictive equations against indirect calorimetry among critically ill patients at different phases of critical illness. This study aimed to determine the degree of agreement and accuracy of predictive equations among ICU patients during acute phase (≤ 5 d), late phase (6-10 d), and chronic phase (≥ 11 d).

DESIGN: This was a single-center prospective observational study that compared resting energy expenditure estimated by 15 commonly used predictive equations against resting energy expenditure measured by indirect calorimetry at different phases. Degree of agreement between resting energy expenditure calculated by predictive equations and resting energy expenditure measured by indirect calorimetry was analyzed using intraclass correlation coefficient and Bland-Altman analyses. Resting energy expenditure values calculated from predictive equations differing by ± 10% from resting energy expenditure measured by indirect calorimetry was used to assess accuracy. A score ranking method was developed to determine the best predictive equations.

SETTING: General Intensive Care Unit, University of Malaya Medical Centre.

PATIENTS: Mechanically ventilated critically ill patients.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN RESULTS: Indirect calorimetry was measured thrice during acute, late, and chronic phases among 305, 180, and 91 ICU patients, respectively. There were significant differences (F= 3.447; p = 0.034) in mean resting energy expenditure measured by indirect calorimetry among the three phases. Pairwise comparison showed mean resting energy expenditure measured by indirect calorimetry in late phase (1,878 ± 517 kcal) was significantly higher than during acute phase (1,765 ± 456 kcal) (p = 0.037). The predictive equations with the best agreement and accuracy for acute phase was Swinamer (1990), for late phase was Brandi (1999) and Swinamer (1990), and for chronic phase was Swinamer (1990). None of the resting energy expenditure calculated from predictive equations showed very good agreement or accuracy.

CONCLUSIONS: Predictive equations tend to either over- or underestimate resting energy expenditure at different phases. Predictive equations with "dynamic" variables and respiratory data had better agreement with resting energy expenditure measured by indirect calorimetry compared with predictive equations developed for healthy adults or predictive equations based on "static" variables. Although none of the resting energy expenditure calculated from predictive equations had very good agreement, Swinamer (1990) appears to provide relatively good agreement across three phases and could be used to predict resting energy expenditure when indirect calorimetry is not available.

来源:Crit Care Med,查看原文。版权归原作者所有。