颅内压升高对瞳孔测量法的影响:一项重复研究
本研究为重复研究,基于「神经科学重症监护瞳孔测量仪评估正常数据建立」注册库中273例患者(16,221次瞳孔观察),同时记录颅内压和瞳孔测量值。将颅内压按<15 mm Hg(正常)与≥15 mm Hg(升高)二分,比较自动瞳孔测量法获得的瞳孔光反射指标。t检验显示除右侧潜伏期(p=0.3000)外,左右侧平均瞳孔测量值差异均有统计学意义,重复测量混合模型p=0.0001。颅内压升高时,左右眼平均瞳孔测量值较正常颅内压降低,但右侧神经瞳孔指数(3.98 vs 3.92;p=0.0300)和左侧潜伏期(0.27 vs 0.25;p<0.0001)例外。结论确认并扩展了McNett等的发现:自动瞳孔测量法显示瞳孔光反射指标恶化与颅内压升高相关。
要点
- 在273例神经重症患者(16,221次观察)中,颅内压≥15 mm Hg时左右眼平均瞳孔测量值较颅内压<15 mm Hg时降低,但右侧神经瞳孔指数和左侧潜伏期为例外。
- t检验显示除右侧潜伏期(p=0.3000)外,左右侧各瞳孔测量值在颅内压正常与升高组间差异均有统计学意义;重复测量混合模型p=0.0001。
- 右侧神经瞳孔指数在颅内压升高时为3.98,正常时为3.92(p=0.0300),方向与其他指标相反。
- 左侧潜伏期在颅内压升高时为0.27,正常时为0.25(p<0.0001),方向与其他指标相反。
- 结论确认并扩展McNett等的发现:自动瞳孔测量法显示瞳孔光反射指标恶化与颅内压升高相关。
适用人群与场景
- 来自「神经科学重症监护瞳孔测量仪评估正常数据建立」注册库的神经重症监护患者,共273例,16,221次瞳孔观察,同时具备颅内压和瞳孔测量值。
诊断标准与关键阈值
- 颅内压升高定义为颅内压≥15 mm Hg,正常定义为颅内压<15 mm Hg。
研究设计与关键结果
- 重复研究,基于注册库273例患者(16,221次瞳孔观察),比较颅内压<15 mm Hg与≥15 mm Hg时自动瞳孔测量法获得的瞳孔光反射指标。
- t检验显示除右侧潜伏期(p=0.3000)外,左右侧平均瞳孔测量值在两组间差异均有统计学意义;重复测量混合模型p=0.0001。
- 颅内压升高时左右眼平均瞳孔测量值较正常颅内压降低,但右侧神经瞳孔指数(3.98 vs 3.92;p=0.0300)和左侧潜伏期(0.27 vs 0.25;p<0.0001)例外。
- 结论确认并扩展McNett等的发现:自动瞳孔测量法显示瞳孔光反射指标恶化与颅内压升高相关。
证据类型、等级与局限
- 证据类型:重复研究,基于多中心注册库数据。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者结论认为,自动瞳孔测量法显示的瞳孔光反射指标恶化与颅内压升高相关,可确认并扩展McNett等的发现。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
UNLABELLED: In a diverse, multicenter population, to confirm or refute the conclusions that pupillary light reflex changes are associated with increased intracranial pressure.
DESIGN: Replication study.
PATIENTS: Within the Establishing Normative Data for Pupillometer Assessments in Neuroscience Intensive Care registry there were 273 patients (16,221 pupillary observations) that included both intracranial pressure and pupillometry values.
MEASUREMENTS AND MAIN RESULTS: To evaluate findings by the previous author, we explored for differences among measures of the pulmonary light reflex obtained from automated pupillometry with ICP values dichotomized as < 15 mm Hg (normal) versus ≥ 15 mm Hg (elevated). Analysis of t-test indicates statistically significant differences for all right and left mean pupilometer values, except right latency (p = 0.3000) and repeated measure mixed model (p = 0.0001). In the setting of increased intracranial pressure, mean pupilometer values were lower for both left and right eyes comparing to normal intracranial pressure, except right neurologic pupil index (3.98, 3.92;p = 0.0300) and left latency (0.27, 0.25; p < 0.0001).
CONCLUSIONS: Our findings confirm and extend those of McNett et al Worsening measures of the pupillary light reflex using automated pupillometry are associated with elevated intracranial pressure.
参考来源
- Al-Obaidi SZ, Atem FD, Stutzman SE, et al. Impact of Increased Intracranial Pressure on Pupillometry: A Replication Study. Crit Care Explor. 2019. PMID: 32166235. doi:10.1097/CCE.0000000000000054
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。