文献速递中毒与环境急症消化、代谢与肾脏急症

威斯康星州2014-2016年一氧化碳探测器减少中毒的有效性

Carbon monoxide detector effectiveness in reducing poisoning, Wisconsin 2014-2016.
PubMed 文献 · Clin Toxicol (Phila) · 2020-03-12
一句话结论无CO探测器者中毒风险为有报警探测器者的3.2倍(95%CI 1.5-6.9),且严重程度评分更高。

该研究基于国家中毒数据系统查询威斯康星州2014-2016年居民住宅内非故意一氧化碳暴露记录(N=703),排除后对有探测器使用记录的408例进行笔记摘录。采用逻辑回归评估有CO探测器报警与CO中毒的关联,线性回归评估与中毒严重程度的关系。结果显示无CO探测器者中毒风险为有报警探测器者的3.2倍(95%CI 1.5, 6.9),且无探测器与结局严重程度评分变化0.34分(95%CI 0.17, 0.54)相关。作者认为无CO探测器暴露者更易中毒且医疗结局更严重。

要点

  • 无CO探测器者发生CO中毒的风险为有报警探测器者的3.2倍(95%CI 1.5, 6.9)。
  • 无CO探测器与结局严重程度评分变化0.34分(95%CI 0.17, 0.54)相关。
  • 研究纳入威斯康星州2014-2016年住宅内非故意CO暴露,最终分析408例有探测器使用记录者。
  • 作者认为无CO探测器暴露者更易中毒且医疗结局更严重。

适用人群与场景

  • 威斯康星州2014-2016年居民住宅内发生非故意一氧化碳暴露者,最终分析有CO探测器使用记录的408例。

研究设计与关键结果

  • 研究类型为基于国家中毒数据系统的查询分析,查询威斯康星州2014-2016年住宅内非故意CO暴露记录N=703,排除后对有探测器使用记录的408例进行笔记摘录。
  • 逻辑回归显示无CO探测器者CO中毒的比值比为3.2倍(95%CI 1.5, 6.9),对照为有报警的CO探测器。
  • 线性回归显示无CO探测器与结局严重程度评分变化0.34分(95%CI 0.17, 0.54)相关,对照为有报警的CO探测器。

证据类型、等级与局限

  • 证据类型为基于中毒数据系统的查询分析;局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为无CO探测器暴露者更易中毒且医疗结局更严重。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Introduction: Carbon monoxide (CO) is a colorless, odorless, and nonirritating gas. The most common exposures are from gas powered appliances such as furnaces, water heaters, stoves, and vehicles. To prevent poisoning, CO detectors with audible alarms were developed. This study aims to evaluate the effectiveness of CO detectors in reducing poisoning in Wisconsin.Methods: Records were queried from National Poison Data System for unintentional CO exposures that occurred in residences in Wisconsin during 2014-2016 (N = 703). After applying sample exclusion criteria, notes were abstracted for cases where CO detector use was mentioned (n = 408). Logistic regression analyses were used to assess the association between having a CO detector alarm and CO poisoning. Linear regression analyses were used to assess the relationship between having a CO detector alarm and poisoning severity.Results: In logistic models, odds of CO poisoning were 3.2 times higher (95% CI: 1.5, 6.9) among those who had no CO detector compared to those who had a CO detector that alarmed. In linear models, not having a CO detector was associated with a 0.34 point (95% CI: 0.17, 0.54) change in outcome severity score compared to having a CO detector that alarmed.Discussion: Individuals who were exposed to CO in the absence of a CO detector were more likely to be poisoned and to have more severe medical outcomes than those that had a CO detector that alarmed.

来源:Clin Toxicol (Phila),查看原文。版权归原作者所有。

参考来源

  1. Christensen GM, Creswell PD, Theobald J, et al. Carbon monoxide detector effectiveness in reducing poisoning, Wisconsin 2014-2016. Clin Toxicol (Phila). 2020. PMID: 32163299. doi:10.1080/15563650.2020.1733592

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。