肺部超声评分对腹腔感染机械通气患者撤机结局的预测价值
该研究纳入2018年1月至12月两家医院收治的腹腔感染机械通气患者76例,排除机械通气<48小时、严重慢性阻塞性肺疾病、气管切开或自动出院者后,53例符合撤机标准者进入撤机流程(自主呼吸试验+拔管)。自主呼吸试验失败组试验前后肺部超声评分均显著高于成功组;试验前评分预测自主呼吸试验失败的AUC为0.82(95%CI 0.67-0.98,P=0.002),最佳界值12.5时敏感度66.7%、特异度84.1%。拔管失败组拔管前及拔管后48小时评分均显著高于拔管成功组;拔管前评分预测拔管失败的AUC为0.81(95%CI 0.69-0.92,P=0.000),最佳界值13.5时敏感度80.0%、特异度65.2%。
要点
- 腹腔感染机械通气患者自主呼吸试验失败组试验前肺部超声评分为13.22±1.99,显著高于成功组的10.79±1.64(P=0.000)。
- 自主呼吸试验前肺部超声评分预测试验失败的AUC为0.82(95%CI 0.67-0.98,P=0.002),最佳界值12.5,敏感度66.7%、特异度84.1%。
- 拔管失败组拔管前肺部超声评分为14.19±1.60,显著高于拔管成功组的12.69±1.81(P=0.006)。
- 拔管前肺部超声评分预测拔管失败的AUC为0.81(95%CI 0.69-0.92,P=0.000),最佳界值13.5,敏感度80.0%、特异度65.2%。
适用人群与场景
- 2018年1月至12月东部战区总医院普通外科研究所及连云港市第一人民医院重症监护病房收治的腹腔感染机械通气患者。
- 排除机械通气时间<48小时、严重慢性阻塞性肺疾病、气管切开或自动出院者。
- 纳入者需满足撤机标准并进入撤机流程(自主呼吸试验及拔管)。
诊断标准与关键阈值
- 自主呼吸试验前肺部超声评分预测自主呼吸试验失败的最佳界值为12.5,敏感度66.7%、特异度84.1%。
- 拔管前(自主呼吸试验结束时)肺部超声评分预测拔管失败的最佳界值为13.5,敏感度80.0%、特异度65.2%。
研究设计与关键结果
- 研究类型为临床研究,最终纳入53例腹腔感染机械通气患者,自主呼吸试验失败9例、成功44例;成功组中拔管成功23例、拔管失败21例。
- 自主呼吸试验失败组试验前评分为13.22±1.99 vs 成功组10.79±1.64(t=-3.911,P=0.000),试验后为19.00±1.12 vs 13.41±1.86(t=-8.665,P=0.000)。
- 自主呼吸试验前评分预测试验失败AUC为0.82(95%CI 0.67-0.98,P=0.002)。
- 拔管失败组拔管前评分为14.19±1.60 vs 成功组12.69±1.81(t=-2.881,P=0.006),拔管后48小时为16.42±1.59 vs 12.78±1.54(t=-7.710,P=0.000)。
- 拔管前评分预测拔管失败AUC为0.81(95%CI 0.69-0.92,P=0.000)。
证据类型、等级与局限
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为肺部超声评分可有效预测腹腔感染机械通气患者的自主呼吸试验结局及拔管后再插管风险。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the value of lung ultrasound score (LUS) on predicting weaning outcome in patients with intro-abdominal infection (IAI) undergoing mechanical ventilation.
METHODS: Patients with IAI undergoing mechanical ventilation admitted to Research Institute of General Surgery of East War Zone Hospital and intensive care unit (ICU) of the First People's Hospital of Lianyungang from January to December in 2018 were included. The patients who satisfied weaning criteria were enrolled in the weaning process, which included spontaneous breathing trial (SBT) and extubation. They were divided into SBT success group and SBT failure group according to whether passed 120-minute SBT or not. LUS scores before and after SBT were compared between the two groups. The patients in the SBT success group were extubated, and they were divided into successful extubation group and failed extubation group for sub-group analysis according to whether re-intubation was needed in 48 hours after extubation. LUS score before extubation (at the end of SBT) and 48 hours after extubation (48 hours after extubation in the successful extubation group or before re-intubation in the failed extubation group) were compared. The receiver operating characteristic (ROC) curve was drawn to evaluate the predictive value of LUS score before SBT for SBT failure and LUS score before extubation for the failure.
RESULTS: A total of 76 patients with IAI undergoing mechanical ventilation were included. Twenty-three patients had duration of mechanical ventilation less than 48 hours, severe chronic obstructive pulmonary disease (COPD), tracheotomy or automatic discharge were excluded, and 53 patients were enrolled. SBT was failed in 9 patients, and successfully performed in 44 patients, of whom 23 patients with successful extubation, and 21 with failed extubation. The LUS scores before and after SBT in the SBT failure group were significantly higher than those in the SBT success group (before SBT: 13.22±1.99 vs. 10.79±1.64, t = -3.911, P = 0.000; after SBT: 19.00±1.12 vs. 13.41±1.86, t = -8.665, P = 0.000). ROC curve analysis showed that the area under ROC curve (AUC) of LUS score before SBT for predicting SBT failure was 0.82 [95% confidence interval (95%CI) was 0.67-0.98, P = 0.002]. When the optimum cut-off value was 12.5, the sensitivity was 66.7%, and the specificity was 84.1%. Sub-group analysis showed that the LUS scores before and after extubation in the failed extubation group were significantly higher than those in the successful extubation group (before extubation: 14.19±1.60 vs. 12.69±1.81, t = -2.881, P = 0.006; after extubation: 16.42±1.59 vs. 12.78±1.54, t = -7.710, P = 0.000). ROC curve analysis showed that the AUC of LUS score before extubation for predicting the failure was 0.81 (95%CI was 0.69-0.92, P = 0.000). When the optimum cut-off value was 13.5, the sensitivity was 80.0%, and the specificity was 65.2%.
CONCLUSIONS: LUS score can effectively predict SBT outcome, risk of re-intubation after extubation in patients with IAI undergoing mechanical ventilation.
参考来源
- Gu C, Xie Y, Zheng T, et al. [Predictive value of lung ultrasound score on weaning outcome in patients with intro-abdominal infection undergoing mechanical ventilation]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2020. PMID: 32148239. doi:10.3760/cma.j.cn121430-20191127-00017
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。