文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

经肺热稀释检测到急性呼吸窘迫综合征中呼气末正压诱导的肺水快速可逆性增加

Transpulmonary thermodilution detects rapid and reversible increases in lung water induced by positive end-expiratory pressure in acute respiratory distress syndrome.
PubMed 文献 · Ann Intensive Care · 2020-03-02
一句话结论在ARDS患者中,改变PEEP水平会引起EVLW小幅度、可逆的平行变化,这些变化并非TPTD技术伪影,而可能源于PEEP对CVP的影响。

该研究在60例ARDS患者中,用PiCCO2装置测量经肺热稀释的血管外肺水(EVLW)。先将PEEP设为使平台压达30 cmH2O的水平(HighPEEPstart,14±2 cmH2O),再将PEEP降至5 cmH2O后15和45分钟测量,随后恢复PEEP至基线。PEEP从HighPEEPstart降至LowPEEP15'时,EVLW从20±4降至18±4 mL/kg,CVP从15±4降至12±4 mmHg,PaO2/FiO2从184±76降至150±69 mmHg,肺容积减少144 [68-420] mL。EVLW变化在「大复张/去复张」组与其他患者间相似,PEEP恢复后EVLW、CVP、PaO2/FiO2均显著回升。线性混合效应模型显示EVLW变化仅由PEEP和CVP变化显著决定。

要点

  • ARDS患者PEEP从14±2 cmH2O降至5 cmH2O后15分钟,EVLW从20±4降至18±4 mL/kg,CVP从15±4降至12±4 mmHg。
  • PEEP降低后PaO2/FiO2从184±76降至150±69 mmHg,肺容积减少144 [68-420] mL,EVLW下降在大去复张组与其他患者间相似。
  • PEEP恢复至基线后,CVP、PaO2/FiO2和EVLW均显著回升,提示EVLW变化可逆。
  • 线性混合效应模型(n=60)显示EVLW变化仅由PEEP变化(p<0.001)和CVP变化(p=0.03)显著决定。
  • 按肺容积变化估计复张时(n=30),CVP仍与EVLW变化显著相关(p<0.001)。

适用人群与场景

  • 60例急性呼吸窘迫综合征(ARDS)患者,PEEP初始设为使平台压达30 cmH2O的水平(HighPEEPstart)。
  • 其中30例患者通过测量去复张肺容积来估计去复张程度。

诊断标准与关键阈值

  • 以呼吸系统顺应性(Crs)变化和测得的去复张肺容积均大于全人群这些变量的中位数,定义「大去复张」患者。

处置流程与药物剂量

  • PEEP设置为使平台压达30 cmH2O的水平(HighPEEPstart),随后将PEEP降至5 cmH2O,在15分钟(LowPEEP15')和45分钟(LowPEEP45')后测量,再将PEEP恢复至基线水平(HighPEEPend)。
  • 使用PiCCO2装置通过经肺热稀释(TPTD)测量血管外肺水(EVLW)。

研究设计与关键结果

  • 研究类型为在60例ARDS患者中进行的自身前后对照研究,干预为改变PEEP水平,主要终点为EVLW变化。
  • PEEP从HighPEEPstart(14±2 cmH2O)降至LowPEEP15'时,EVLW从20±4降至18±4 mL/kg,CVP从15±4降至12±4 mmHg,PaO2/FiO2从184±76降至150±69 mmHg,肺容积减少144 [68-420] mL。
  • EVLW下降在「大去复张」患者与其他患者间相似。
  • PEEP恢复至HighPEEPend后,CVP、PaO2/FiO2和EVLW均显著回升。
  • 线性混合效应模型(n=60)显示EVLW变化仅由PEEP变化(p<0.001)和CVP变化(p=0.03)显著决定;按肺容积变化估计复张时(n=30),CVP仍与EVLW变化显著相关(p<0.001)。

证据类型、等级与局限

  • 证据类型:在60例ARDS患者中进行的自身前后对照研究。
  • 试验注册号:RCB: 2015-A01654-45,注册日期2015年10月23日。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,ARDS患者改变PEEP水平引起的EVLW变化并非TPTD技术伪影,而可能源于PEEP诱导的CVP变化(肺淋巴引流的下游压力)。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

PURPOSE: It has been suggested that, by recruiting lung regions and enlarging the distribution volume of the cold indicator, increasing the positive end-expiratory pressure (PEEP) may lead to an artefactual overestimation of extravascular lung water (EVLW) by transpulmonary thermodilution (TPTD).

METHODS: In 60 ARDS patients, we measured EVLW (PiCCO2 device) at a PEEP level set to reach a plateau pressure of 30 cmH2O (HighPEEPstart) and 15 and 45 min after decreasing PEEP to 5 cmH2O (LowPEEP15' and LowPEEP45', respectively). Then, we increased PEEP back to the baseline level (HighPEEPend). Between HighPEEPstart and LowPEEP15', we estimated the degree of lung derecruitment either by measuring changes in the compliance of the respiratory system (Crs) in the whole population, or by measuring the lung derecruited volume in 30 patients. We defined patients with a large derecruitment from the other ones as patients in whom the Crs changes and the measured derecruited volume were larger than the median of these variables observed in the whole population.

RESULTS: Reducing PEEP from HighPEEPstart (14 ± 2 cmH2O) to LowPEEP15' significantly decreased EVLW from 20 ± 4 to 18 ± 4 mL/kg, central venous pressure (CVP) from 15 ± 4 to 12 ± 4 mmHg, the arterial oxygen tension over inspired oxygen fraction (PaO2/FiO2) ratio from 184 ± 76 to 150 ± 69 mmHg and lung volume by 144 [68-420] mL. The EVLW decrease was similar in "large derecruiters" and the other patients. When PEEP was re-increased to HighPEEPend, CVP, PaO2/FiO2 and EVLW significantly re-increased. At linear mixed effect model, EVLW changes were significantly determined only by changes in PEEP and CVP (p < 0.001 and p = 0.03, respectively, n = 60). When the same analysis was performed by estimating recruitment according to lung volume changes (n = 30), CVP remained significantly associated to the changes in EVLW (p < 0.001).

CONCLUSIONS: In ARDS patients, changing the PEEP level induced parallel, small and reversible changes in EVLW. These changes were not due to an artefact of the TPTD technique and were likely due to the PEEP-induced changes in CVP, which is the backward pressure of the lung lymphatic drainage. Trial registration ID RCB: 2015-A01654-45. Registered 23 October 2015.

来源:Ann Intensive Care,查看原文。版权归原作者所有。

参考来源

  1. Gavelli F, Teboul JL, Azzolina D, et al. Transpulmonary thermodilution detects rapid and reversible increases in lung water induced by positive end-expiratory pressure in acute respiratory distress syndrome. Ann Intensive Care. 2020. PMID: 32124129. doi:10.1186/s13613-020-0644-2

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。