胸水含量:预测机械通气脱机失败的新参数
本研究为观察性队列研究,纳入64例符合拔管条件的危重外科患者,在启动自主呼吸试验前使用电阻抗心排量技术测量胸水含量(TFC),随访拔管后分为脱机成功组与失败组。脱机成功41/64(64%)。失败组TFC显著高于成功组。TFC预测脱机失败的ROC曲线下面积(AUC)为0.69(95%CI 0.57-0.8),截断值>50 kΩ⁻¹,预测能力中等;在射血分数<40%亚组中AUC为0.93(95%CI 0.72-1),截断值>50 kΩ⁻¹,预测能力优秀。作者认为TFC对危重外科患者脱机结局有中等预测能力,在射血分数<40%亚组中TFC>50 kΩ⁻¹预测脱机失败能力优秀。
要点
- 在射血分数<40%的危重外科患者中,自主呼吸试验前TFC>50 kΩ⁻¹预测脱机失败能力优秀(AUC 0.93,95%CI 0.72-1)。
- 在全部危重外科患者中,TFC预测脱机失败能力中等(AUC 0.69,95%CI 0.57-0.8),截断值>50 kΩ⁻¹。
- 脱机失败组TFC显著高于脱机成功组。
- 64例中脱机成功41例(64%);20例存在心脏收缩功能受损,其中13/20(64%)成功拔管。
适用人群与场景
- 危重外科患者,符合拔管条件并准备接受自主呼吸试验者。
诊断标准与关键阈值
- TFC预测脱机失败的截断值为>50 kΩ⁻¹(全部患者及射血分数<40%亚组均为此值)。
研究设计与关键结果
- 观察性队列研究,纳入64例危重外科患者,脱机成功41/64(64%)。
- 20例(31%)存在心脏收缩功能受损,其中13/20(64%)成功拔管。
- 脱机失败组TFC显著高于脱机成功组。
- TFC预测脱机失败的AUC为0.69(95%CI 0.57-0.8),截断值>50 kΩ⁻¹,预测能力中等。
- 射血分数<40%亚组中TFC预测脱机失败的AUC为0.93(95%CI 0.72-1),截断值>50 kΩ⁻¹,预测能力优秀。
证据类型、等级与局限
- 证据类型:观察性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为TFC对危重外科患者脱机结局有中等预测能力,在射血分数<40%亚组中TFC>50 kΩ⁻¹预测脱机失败能力优秀。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Weaning of patients from the mechanical ventilation remains one of the critical decisions in intensive care unit. This study aimed to evaluate the accuracy of thoracic fluid content (TFC) as a predictor of weaning outcome.
METHODS: An observational cohort study included 64 critically ill surgical patients who were eligible for extubation. Before initiating the spontaneous breathing trial, the TFC was measured using the electrical cardiometry technology. Patients were followed up after extubation and divided into successful weaning group and failed weaning group. Both groups were compared according to respiratory and cardiovascular parameters. Receiver operating characteristic (ROC) curves were constructed to evaluate the ability of TFC to predict weaning outcome.
RESULTS: The number of successfully weaned patients was 41/64 (64%). Twenty (31%) patients had impaired cardiac contractility, and of them, 13/20 (64%) patients were successfully extubated. Both groups, successful weaning group and failed weaning group, were comparable in most of baseline characteristics; however, the TFC was significantly higher in the failed weaning group compared to the successful weaning group. The area under the ROC curves (AUCs) showed moderate predictive ability for the TFC in predicting weaning failure (AUC [95% confidence interval] 0.69 [0.57-0.8], cutoff value > 50 kΩ-1), while the predictive ability of TFC was excellent in the subgroup of patients with ejection fraction < 40% (AUC [95% confidence interval 0.93 [0.72-1], cutoff value > 50 kΩ-1).
CONCLUSIONS: Thoracic fluid content showed moderate ability for predicting weaning outcome in surgical critically ill patients. However, in the subgroup of patients with ejection fraction less than 40%, TFC above 50 kΩ-1 has an excellent ability to predict weaning failure.
参考来源
- Fathy S, Hasanin AM, Raafat M, et al. Thoracic fluid content: a novel parameter for predicting failed weaning from mechanical ventilation. J Intensive Care. 2020. PMID: 32161651. doi:10.1186/s40560-020-00439-2
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。